Page 1
OPERATION AND PARTS MANUAL MODEL QP2E CENTRIFUGAL PUMP (ROBIN EX130D51111 GASOLINE ENGINE) Revision #0 (02/12/09) To fi nd the latest revision of this publication, visit our website at: www.multiquip.com THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES.
Terms And Conditions Of Sale — Parts ....54 Troubleshooting ..........24-25 Explanation Of Code In Remarks Column..... 26 Suggested Spare Parts ......... 27 Component Drawing Pump Assy............28-29 PAGE 4 — QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09)
All orders are treated as Standard Orders and will ship the same day if received prior to 3PM PST. WE ACCEPT ALL MAJOR CREDIT CARDS! QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09) — PAGE 5...
You CAN be KILLED or SERIOUSLY INJURED if you DO NOT follow these directions. CAUTION You CAN be INJURED if you DO NOT follow these directions. PAGE 6 — QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09)
Page 7
Equipment should be stored in a clean, dry location ALWAYS check the equipment for loosened threads or out of the reach of children. bolts before starting. QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09) — PAGE 7...
Page 8
Tighten fuel tank cap securely and close fuel cock to prevent fuel from spilling. ALWAYS tie down the equipment during transport by securing the equipment with rope. PAGE 8 — QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09)
■ DO NOT use food or plastic containers to dispose of hazardous waste. ■ DO NOT pour waste, oil or fuel directly onto the ground, down a drain or into any water source. QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09) — PAGE 9...
Recoil Starter Weight 30.9 lbs (14 kg) 11.7 x 13.4 x 12.5 in Dimensions (L x W x H) (297 x 341 x 318 mm) QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09) — PAGE 11...
4,000 (1,219) and leaks. A small suction leak in the hose or fi ttings could prevent the pump from priming. 6,000 (1,829) 8,000 (2,438) 10,000 (3,048) PAGE 12 — QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09)
Running the hose on the inlet side of the pump. the pump with the strainer above water for long periods can damage pump. QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09) — PAGE 13...
Fuel Valve Lever — OPEN to let fuel fl ow, CLOSE to stop the fl ow of fuel. PAGE 14 — QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09)
The strainer should be positioned so it will remain completely under water. Running the pump with the strainer above water for long periods can damage the CLOSED pump. Figure 8. Choke Lever PAGE 16 — QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09)
(Figure 8) to the CLOSED position. If the engine has position. not started repeat steps 1 through 5. Before the pump is put into operation run the engine for 3-5 minutes. QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09) — PAGE 17...
NOTICE 25 in. Hg (inches of mercury) translates into 25 feet of lift at sea level. PAGE 18 — QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09)
Page 19
Vacuum test may be performed without water fl owing through the discharge port. However, it is recommended to have water fl owing to prevent any heat-up. QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09) — PAGE 19...
Page 20
Refer to the Robin shop Manual for service procedures. (3) For commercial use, log hours of operation to determine proper maintenance intervals. PAGE 20 — QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09)
Page 21
Rinse and dry thoroughly. Dip the element in clean engine oil and completely squeeze out the excess oil from the element before installing. Figure 13. Draining Engine Oil QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09) — PAGE 21...
Page 22
(new or used) through the discharge opening on the pump and crank the engine several times. This will prevent excessive corrosion and also keep the mechanical seal lubricated. PAGE 22 — QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09)
Page 23
NOTES QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09) — PAGE 23...
Impeller does not turn: Adjust clearance by removing shim from pump is hard to start. Impeller and volute binding? behind impeller. Defective engine? See Engine Owner's Manual. QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09) — PAGE 25...
TBD (To Be Determined) is generally used to show a and certain washers and nuts. part that has not been assigned a formal part number at the time of publication PAGE 26 — QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09)