MULTIQUIP QP2TK Operation Manual
MULTIQUIP QP2TK Operation Manual

MULTIQUIP QP2TK Operation Manual

Trash pump kubota oc60-e4 diesel engine

Advertisement

Quick Links

OPERATION MANUAL
MODEL QP2TK
TRASH PUMP
(KUBOTA OC60-E4 DIESEL ENGINE)
Revision #4 (05/20/20)
To find the latest revision of this publication or
associated parts manual, visit our website at:
www.multiquip.com
THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the QP2TK and is the answer not in the manual?

Questions and answers

Summary of Contents for MULTIQUIP QP2TK

  • Page 1 OPERATION MANUAL MODEL QP2TK TRASH PUMP (KUBOTA OC60-E4 DIESEL ENGINE) Revision #4 (05/20/20) To find the latest revision of this publication or associated parts manual, visit our website at: www.multiquip.com THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES.
  • Page 2: Proposition 65 Warning

    PROPOSITION 65 WARNING PAGE 2 — QP2TK TRASH PUMP • OPERATION MANUAL — REV. #4 (05/20/20)
  • Page 3: Table Of Contents

    Maintenance (Pump) ........19-20 Maintenance (Engine) ........21-22 Storage ..............23 Troubleshooting (Engine) ........24 Troubleshooting (Engine/Pump) ......25 NOTICE Specifications and part numbers are subject to change without notice. QP2TK TRASH PUMP • OPERATION MANUAL — REV. #4 (05/20/20) — PAGE 3...
  • Page 4: Safety Information

    COULD result in DEATH or SERIOUS INJURY. CAUTION Indicates a hazardous situation which, if not avoided, COULD result in MINOR or MODERATE INJURY. NOTICE Addresses practices not related to personal injury. PAGE 4 — QP2TK TRASH PUMP • OPERATION MANUAL — REV. #4 (05/20/20)
  • Page 5 Also, know the phone numbers of the nearest ambulance, doctor and fi re department. This information will be invaluable in the case of an emergency. QP2TK TRASH PUMP • OPERATION MANUAL — REV. #4 (05/20/20) — PAGE 5...
  • Page 6 „ DO NOT overfi ll tank, since spilled fuel could ignite if it muffl er or cylinder. Allow these parts to cool comes into contact with hot engine parts or sparks from before servicing equipment. the ignition system. PAGE 6 — QP2TK TRASH PUMP • OPERATION MANUAL — REV. #4 (05/20/20)
  • Page 7 „ DO NOT lift machine to unnecessary heights. seek medical attention. „ ALWAYS tie down equipment during transport by securing the equipment with rope. QP2TK TRASH PUMP • OPERATION MANUAL — REV. #4 (05/20/20) — PAGE 7...
  • Page 8 Recyclers and manufacturers alike promote the process of recycling metal. Using a metal recycling center promotes energy cost savings. PAGE 8 — QP2TK TRASH PUMP • OPERATION MANUAL — REV. #4 (05/20/20)
  • Page 9: Specifications (Pump)

    37.7 psi (260 kPa) Dry Net Weight 157 lbs. (71 Kg.) Table 2. Dimensions Reference Dimension in. (mm) Letter 23.8 (605) 23.4 (595) 26.9 (685) Figure 1. Dimensions QP2TK TRASH PUMP • OPERATION MANUAL — REV. #4 (05/20/20) — PAGE 9...
  • Page 10: Specifications (Engine)

    3.3 FT 10 FT 16.7 FT 23.3 FT 23.3 FT 16.7 FT 10 FT 3.3 FT U.S GALLONS PER MINUTE LITTERS PER MINUTE Figure 2. QP2TK Performance Curve PAGE 10 — QP2TK TRASH PUMP • OPERATION MANUAL — REV. #4 (05/20/20)
  • Page 11: General Information

    NEVER place the pump on soft soil. The suction hose or pipe connection should always be checked for tightness and leaks. A small suction leak in the hose or fittings could prevent the pump from priming. QP2TK TRASH PUMP • OPERATION MANUAL — REV. #4 (05/20/20) — PAGE 11...
  • Page 12: Pump Components

    PUMP COMPONENTS Figure 3 shows key component areas of the QP2TK. Figure 3. QP2TK Key Component Callouts PAGE 12 — QP2TK TRASH PUMP • OPERATION MANUAL — REV. #4 (05/20/20)
  • Page 13 (Cam and Groove lock) hose. For quick disconnect connections, an optional coupler (A200A) is necessary. Contact MQ Parts Department for ordering assistance. QP2TK TRASH PUMP • OPERATION MANUAL — REV. #4 (05/20/20) — PAGE 13...
  • Page 14: Basic Engine

    5. Ignition Switch — With ignition key inserted, turn key smoothly (recoil start - serial number 0181 and above). clockwise to start engine. PAGE 14 — QP2TK TRASH PUMP • OPERATION MANUAL — REV. #4 (05/20/20)
  • Page 15: Inspection (Engine)

    You must frequently check the oil level of the engine.There is no low oil shutoff feature for protection and operating the pump with low oil levels will cause severe damage to the engine. QP2TK TRASH PUMP • OPERATION MANUAL — REV. #4 (05/20/20) — PAGE 15...
  • Page 16: Setup

    Figure 8. Pump Placement PAGE 16 — QP2TK TRASH PUMP • OPERATION MANUAL — REV. #4 (05/20/20)
  • Page 17: Operation

    10 x 7 x 12 inches). HANDLE b. Manual recoil start (on units with serial number Figure 9. Starting the Engine 0181and above). CAUTION ALWAYS run engine at full speed while pumping. QP2TK TRASH PUMP • OPERATION MANUAL — REV. #4 (05/20/20) — PAGE 17...
  • Page 18 5. Once the engine starts, allow it to run for about 10 seconds before advancing the engine speed control lever to the HIGH position. CAUTION ALWAYS run engine at full speed while pumping. PAGE 18 — QP2TK TRASH PUMP • OPERATION MANUAL — REV. #4 (05/20/20)
  • Page 19: Maintenance (Pump)

    This prevents backflow and allows for faster priming when the engine is restarted. QP2TK TRASH PUMP • OPERATION MANUAL — REV. #4 (05/20/20) — PAGE 19...
  • Page 20 INTO 25 FEET OF LIFT SHOULD BE BETWEEN -100 AT SEA LEVEL. -25 AND -20 IN. HG. in. Hg PUMP VACUUM WIKA TESTER Figure 10. Pump Vacuum Tester PAGE 20 — QP2TK TRASH PUMP • OPERATION MANUAL — REV. #4 (05/20/20)
  • Page 21: Maintenance (Engine)

    Refer to the KUBOTA shop Manual for service procedures. 3. For commercial use, log hours of operation to determine proper maintenance intervals. NOTICE Refer to manufacturer engine manual for specific servicing instructions. QP2TK TRASH PUMP • OPERATION MANUAL — REV. #4 (05/20/20) — PAGE 21...
  • Page 22 You must frequently check the oil level of the engine.There is no low oil shutoff feature for protection and operating the pump with low oil levels will cause severe damage to the engine. PAGE 22 — QP2TK TRASH PUMP • OPERATION MANUAL — REV. #4 (05/20/20)
  • Page 23: Storage

    This will prevent excessive corrosion and also keep the mechanical seal lubricated. „ Disconnect the battery cables from the battery. QP2TK TRASH PUMP • OPERATION MANUAL — REV. #4 (05/20/20) — PAGE 23...
  • Page 24: Troubleshooting (Engine)

    Correct engine oil level. Use No. 2-D diesel fuel only. Check the fuel Injection pump wear? injection pump element and delivery valve assembly and replace as necessary. PAGE 24 — QP2TK TRASH PUMP • OPERATION MANUAL — REV. #4 (05/20/20)
  • Page 25: Troubleshooting (Engine/Pump)

    Impeller does not turn, pump is hard to start. Adjust clearance by removing shim from behind Impeller and volute binding? impeller. Defective engine? See Engine Owner's Manual. QP2TK TRASH PUMP • OPERATION MANUAL — REV. #4 (05/20/20) — PAGE 25...
  • Page 26 © COPYRIGHT 2020, MULTIQUIP INC. Multiquip Inc , the MQ logo are registered trademarks of Multiquip Inc. and may not be used, reproduced, or altered without written permission. All other trademarks are the property of their respective owners and used with permission.