THE OSCILLATORS
(Continued)
MOD VCO FREQUENCY
This sets the frequency of Labyrinth's triangle wave MOD VCO—from low
frequencies to audio rate (~1.3 kHz).
MOD VCO EG1 AMT
This sets the amount that EG1 modulates the MOD VCO FREQUENCY. It
has bipolar control, with positive modulation above 12 o'clock and negative
modulation below.
MOD VCO SEQ2 AMT
This sets the amount that the sequence from SEQ2 modulates the MOD VCO
SEQ2 AMT
FREQUENCY. Set all the way up (at QTZ) it will follow the quantized sequence
from SEQ2.
QTZ
MOD VCO FM AMT
This sets the frequency modulation depth from MOD VCO to VCO. This control
utilizes thru-zero frequency modulation which will preserve the tonal center of
the VCO regardless of the MOD VCO FM AMT setting.