om 2
PRE-OPERATION
(1) CHARGING
CONNECTION
Charge any new battery pack or battery packs not used for
2 months or more.
USE ONLY one charger.
BC-73E/D
(To AC outlet)
To EXT. DC jack
(BP-81 ~ 84, 90)
BC-74A/E/D/V
(To AC outlet)
(To cigarette
Cy} lighter socket)
© black
OPC-254
(To External
13.8 V DC)
® Charging periods
BC-72
(BP-90 cannot be charged
with BC-72.)
1~ 1.5 hrs. with BC-72.
15 hrs. with another charger.
@An
optional
AD-14
CHARGE
ADAPTER
is available to
charge a battery pack without the transceiver.
(2) BATTERY
PACK
CAUTIONS
1. NEVER throw the battery pack into fire.
2. NEVER
disassemble the battery pack.
3. AVOID
operating or charging the battery pack in places
below 0°C (+32°F) or over +45°C (+113°F).
4. NEVER
obstruct the holes on the bottom of the battery
pack when charging with the BC-72.
5. NEVER charge dry batteries with the BP-90.
6. AVOID shorting the terminals.
(3) USING
THE
BATTERY
PACK
WISELY
The
battery
pack
is designed
to
withstand
recharging
periods
longer
than
1 week
or
more
and can
be fully
discharged.
However, overcharging or complete discharging
shorten
the life of a battery.
The battery pack can be
recharged
about
300
times
but
its battery
life can
be
lengthened to about 500 times as follows:
1. Avoid overcharging.
Charging times should be less than
48 hours.
2. Use battery capacity almost completely.
We recommend
battery charging after transmitting becomes impossible.