PAIR OF PUMPS

Table of Contents

Instructions
2
2
2
Items included in system
3
3
3
4
5
5
5
5
5
5
Product Operation
Float switches
6
/
6
3
16
6
6
6
6
7,8
8,9
9
9
10
10,11
11
Testing the System
11
Technical support
11
13
Warranty
14
15,16
Instruction Manual & Safety Warnings
Combination Primary and Backup Sump Pump System
Scan the QR code
for more information
about the PS-C11
Combination Sump
Pump System
Model PS-C11
IMPORTANT: Even if you have the Pro Series™ PS-C11
Combination Sump Pump System installed by someone
else, you must read and follow the safety information
contained in this manual. Failure to do so could result
in property damage, serious injury, or death.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PRO PS-C11 and is the answer not in the manual?

Questions and answers

Summary of Contents for Glentronics PRO PS-C11

  • Page 1: Table Of Contents

    Instruction Manual & Safety Warnings Combination Primary and Backup Sump Pump System Model PS-C11 PAIR OF PUMPS Table of Contents Important Safety Warnings and Understanding the Warning Instructions Lights and Alarms Silencing the alarm during Electrical precautions an emergency Battery preparation AC power alarm Battery precautions Pump was activated...
  • Page 2: Important Safety Warnings And

    Always shield eyes and face from battery. disconnect the cables from the battery before Glentronics' technical support at 800-991- Keep vent caps tight and level. attempting any maintenance or cleaning. 0466. Return the product to the manufacturer DANGER •...
  • Page 3: Introduction

    • No-hub coupling to operate, the second float automatically maintenance free (AGM) batteries may not existing plumbing be compatible with this system. Glentronics, activates the pump. • A PVC pipe connector or a rubber union Backup Pump Float Switch • PVC pipe cleaner and cement...
  • Page 4: Installing The Pipe And Pump

    Installing the Pipe and Pump sump pit is not clean, remove as much of the discharge pipe. Connect debris as possible. The pumps are attached to the system with the no- The Pro Series combination system is a sump foot to raise them above any debris. hub coupling, and tighten compact and will fit in a sump pit as small as upper...
  • Page 5: Battery Instructions

    Slide the washer onto the bolt, then put Bolt Bolt 5-45 seconds. The manufacturer default is Glentronics, Inc. cannot guarantee the the ring lug on the red wire onto the about 10 seconds. compatibility of other brands of batteries. bolt. Remove the protective cap from the The use of a Pro Series battery is highly POSITIVE (RED) terminal on the battery.
  • Page 6: 16 -Inch Weep Holes Controllers

    Pro During a power outage or if more water is problem is when problem Series part #1015003. Contact Glentronics at entering the sump than the primary pump can Warning corrected is corrected ①...
  • Page 7: Replacing The Backup Pump

    • Make sure the discharge pipe is not clogged piece of cardboard (or another nonmetallic 9. Remove the elbow from the new pump. DANGER or frozen. material) to remove any hydrogen or You will not need it. Squeeze the clamps Risk of electrical shock or battery explosion, oxygen gas that may have been emitted on the pump elbow and insert the elbow...
  • Page 8: Replacing The Primary Pump

    Glentronics. (a) You will need to loosen the 14. Connect the backup pump to the back of piggyback controller from the wall outlet. drain any remaining water. screws on the no hub couplings on both the black control unit. Unplug the charger for the backup pump 7.
  • Page 9: System Operating

    Use a #4 or a -inch drill it means that the unit is not receiving AC Glentronics. (a) Unscrew the check valve using a surge protector.) bit. Screw the sump foot on to the pump power. Either the AC power is out, the circuit on the primary pump and screw in a new with #14 x ¾-inch self-tapping stainless...
  • Page 10: Cleaning Battery Terminals

    use your car battery, or recharge this battery control unit, too. piggyback controller from the wall outlet. by connecting it to your car battery. Once the Unplug the charger for the backup pump 2. Remove the cover of the battery box by AC power is restored, the battery will recharge control unit, too.
  • Page 11: Test-Reset Button

    You can receive technical support, parts, or 9. Plug the primary pump into the blue electric shock. Failure to do so could cause service information by calling Glentronics, Inc. piggyback controller and then plug the serious injury or death. Review the safety at 800-991-0466, or by visiting the Pro Series controller into the wall outlet.
  • Page 12: Replacement Parts Diagram & List

    Replacement Parts List BOTTOM VIEW PS -C11 Description Part No. Controller for backup pump PHCC-1000-CONT Dual float switch with controller for AC pump DFC1.5 1/3 HP AC sump pump S1033-NS PHCC 1000 backup pump 1011009 Battery box 1113003 PVC “wye” fitting 1120007 Sump foot 1143000...
  • Page 13: Troubleshooting Guide

    Primary Pump Troubleshooting Guide Backup Pump Troubleshooting Guide DANGER DANGER Read safety warnings & instructions before attempting any repairs or maintenance. Read safety warnings & instructions before attempting any repairs or maintenance. Potential Cause THE PUMP WILL NOT START OR RUN Solutions Potential Cause BATTERY PROBLEM...
  • Page 14 GLENTRONICS, INC., this warranty shall no longer be valid. Prior to defective operation, the unit must not have been previously altered, repaired or serviced by anyone other than GLENTRONICS, INC., or its agent; the serial number on the unit must not have been altered or removed; the unit must not have been subject to accident, misuse, abuse or operated contrary to the instructions contained in the accompanying manual.
  • Page 15: Other Products

    Additional Products to Help Protect Your Basement Maintenance Free Battery Clenit Pump and Pro Series CONNECT Sewage Pump Pit Cleaner WiFi2 Module B12-100 E7040 PS-WIFI2 FEATURES AND BENEFITS: ƒ Sends emails, texts or in-app notifications Compatible with: and status alerts to your phone, tablet or computer ƒ...
  • Page 16 20-Ft. Extension FEATURES AND BENEFITS: ƒ For use with 360˚ Sensor (PS-WS360) and EXT-PWA20 Water Sensor (PS-WS) ƒ 20' cord ƒ Rubber gasket and sleeve for waterproofing the connection between the extension and sensor © 2024, Glentronics, Inc. 1806189 06/24...