E V
C
IG
ISION
AMERAS
Alvium G5/G5X
User Guide
V2.1.2
FW 00.13.02.46198eb2
Note: Lenses are not part of this product.
Allied Vision Technologies GmbH // Taschenweg 2a, 07646 Stadtroda, Germany
2024-Jun-12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Alvium G5 and is the answer not in the manual?

Questions and answers

Summary of Contents for Allied Vision Alvium G5

  • Page 1 ISION AMERAS Alvium G5/G5X User Guide V2.1.2 FW 00.13.02.46198eb2 Note: Lenses are not part of this product. Allied Vision Technologies GmbH // Taschenweg 2a, 07646 Stadtroda, Germany 2024-Jun-12...
  • Page 2: Read Before Use

    The threads of the lens mount can have sharp edges. Intended use Intended use of Allied Vision product is the integration into vision systems by professionals. All Allied Vision product is sold in a B2B setting. Alvium G5/G5X User Guide V2.1.2...
  • Page 3: Dansk

    Fare for snitsår på linsemodulets skarpe kanter Linsemodulets gevind kan have skarpe kanter. Tilsigtet brug Allied Vision produktets tilsigtede brug er en indbygning i et visionssystem, udført af fagfolk. Alle Allied Vision produkter sælges i B2B. Alvium G5/G5X User Guide V2.1.2...
  • Page 4: Deutsch

    Eine fallende Kamera oder ein fallendes Objektiv kann Verletzungen verursachen. VORSICHT Schnitte durch scharfkantige Objektivgewinde Objektivgewinde können scharfe Kanten haben. Bestimmungsgemäßer Gebrauch Allied Vision Produkte sind bestimmt für die Integration in Bildverarbeitungs- systeme durch Fachpersonal. Alle Allied Vision Produkte werden in einer B2B-Umgebung verkauft. Alvium G5/G5X User Guide V2.1.2...
  • Page 5: Español

    Las roscas de los objetivos pueden tener bordes afilados. Uso previsto El uso previsto del producto Allied Vision es la integración en el sistema de visión por parte de profesionales. Todos los productos Allied Vision se venden dentro de una relación B2B.
  • Page 6: Suomi

    Putoava kamera tai linssi voi aiheuttaa vammoja. HUOMIO Linssien kiinnikkeiden terävien reunojen aiheuttamien viiltovammojen vaara Linssin kiinnikkeiden kierteiden reunat voivat olla teräviä. Käyttötarkoitus Allied Vision -tuotteen käyttötarkoitus on integrointi kuvajärjestelmiin ammattilaisten toimesta. Kaikki Allied Vision -tuotteet myydään B2B-ympäristössä. Alvium G5/G5X User Guide V2.1.2...
  • Page 7: Français

    Les filetages des montures d’objectif peuvent présenter des bords tranchants. Utilisation prévue L’utilisation prévue du produit Allied Vision est son intégration dans des systèmes de vision par le soin de professionnels. Tout produit Allied Vision est vendu dans un cadre B2B. Alvium G5/G5X User Guide V2.1.2...
  • Page 8: He - ‫ת‬ ‫י ר‬ ‫ב ע

    ‫ו י מ‬ AlliedVision ‫י‬ ‫ר צ‬ ‫ו מ‬ ‫ת‬ ‫ב‬ ‫י ב‬ ‫ס‬ ‫ב‬ ‫ש‬ ‫ו מ‬ ‫י ש‬ ‫ל‬ ‫ם י‬ ‫ר כ‬ ‫מ נ‬ AlliedVision ‫י‬ ‫ר צ‬ ‫ו מ‬ ‫ל כ‬ Alvium G5/G5X User Guide V2.1.2...
  • Page 9: Italiano

    Pericolo di tagliarsi sui bordi affilati degli attacchi della lente I bordi della filettatura dell’attacco della lente possono essere affilati. Uso previsto Il prodotto Allied Vision è concepito per essere integrato in sistemi di monitoraggio in campo professionale. Tutti i prodotti Allied Vision sono venduti in uno scenario B2B.
  • Page 10: Ja - 日本語

    Read before use JA - 日本語 安全性 本カメラを使用する前に、この安全の手引きをお読みください。常に、 警告事項を守ってください。必ず、Intended use 40 ページの通りに、本カ メラを使用してください。 注意 やけどの危険性 作動中のカメラは、やけどを引き起こす温度まで熱くなる恐れがありま す。 注意 カメラまたはレンズの落下によるけが カメラまたはレンズが落下すると、けがをする恐れがあります。 注意 レンズマウントの鋭利な端部で切り傷の危険性 レンズマウントのギザギザの部分が鋭利である可能性があります。 用途 Allied Vision製品は、専門家が視覚装置に統合することを意図したもの です。すべてのAllied Vision製品は、企業間取り引き用に販売されてい ます。 Alvium G5/G5X User Guide V2.1.2...
  • Page 11: Nederlands

    Risico van snijwonden door scherpe randen van lensbevestigingen Het schroefdraad van de lensbevestiging kan scherpe randen hebben. Beoogd gebruik Het beoogde gebruik van het Allied Vision-product is de integratie in optische systemen door professionals. Alle Allied Vision-producten worden verkocht in de B2B-markt.
  • Page 12: Norsk

    Risiko for kutt fra skarpe kanter på linsefester Sporene på linsefestet kan ha skarpe kanter. Tiltenkt bruk Den tiltenkte bruken av Allied Vision-produktet er integrering i visjonssystemer av profesjonelle. Alle Allied Vision-produkter selges i en forretning til forretning-situasjon. Alvium G5/G5X User Guide V2.1.2...
  • Page 13: Svenska

    Risk för skärsår från vassa kanter på objektivfattningar Objektivets gängor kan ha vassa kanter. Avsedd användning Den avsedda användningen av Allied Vision-produkter är integrering i visionssystem av fackmän. Samtliga Allied Vision-produkter säljs i en B2B-miljö. Alvium G5/G5X User Guide V2.1.2...
  • Page 14: Zh - 简体中文版

    Read before use ZH - 简体中文版 安全需知 使用本相机前,请阅读本安全说明书。请务必遵守相关警告 和 Intended use 于第 40 页 . 注意事项 烫伤风险 相机操作过程中温度可能上升并导致烫伤风险。 注意事项 相机或者镜头跌落造成伤害 相机或者镜头可能会跌落并造成伤害。 注意事项 镜头接口的锐利边缘划伤风险 镜头接口螺纹边缘可能较为锐利。 预期用途 Allied Vision 产品的预期用途是由专业人士整合到视觉系统中。所有 Allied Vision 的产品均通过 B2B 渠道销售。 Alvium G5/G5X User Guide V2.1.2...
  • Page 15: Alvium G5/G5X Cameras At A Glance

    Alvium G5/G5X cameras at a glance Get an overview of Alvium G5/G5Xdocumentation: Consider for Alvium G5/G5X cameras ........16 Shipping contents..............16 What else do you need? ............16 Alvium Pol - using polarization ..........17 Alvium G5/G5X User Guide V2.1.2...
  • Page 16: Consider For Alvium G5/G5X Cameras

    Topic Details Camera startup Current Alvium G5/G5X cameras have a boot sequence that may take up to 30 seconds. We time aim to reduce the startup-time by future updates. Alvium G5/G5X cameras require different hardware and settings than 1000BASE-T cameras like Mako or Prosilica GT cameras.
  • Page 17: Alvium Pol - Using Polarization

    I/O cables, power www.alliedvision.com/en/products/accessories supplies, lenses, and tripod adapters Table 1: Downloads for Alvium G5/G5X cameras (sheet 2 of 2) Alvium Pol - using polarization Alvium polarizer cameras are equipped with Sony IMX Polarsens sensors that support four-directional polarization using filters directly in front of the sensor.
  • Page 18 Alvium G5/G5X cameras at a glance Current models: • Alvium G5-507m/c Pol on page 78 • Alvium G5-508m/c Pol on page 84 Please observe For first series models, pixel processing has not been adjusted to enable the complete functionality available with non-polarizer models: •...
  • Page 19: Contact Us

    T// +86 21 64861133 102 Pickering Way - Suite 502 Exton, PA 19341, USA Singapore Toll-free// +1-877-USA-1394 Allied Vision Technologies Asia Pte. Ltd T// +1 978 225 2030 82 Playfair Rd, #07-01 D'Lithium Singapore 368001 T// +65 6634 9027 Alvium G5/G5X User Guide V2.1.2...
  • Page 20: Table Of Contents

    Consider for Alvium G5/G5X cameras ........
  • Page 21 Alvium G5-320 VSWIR )coming soon( ........
  • Page 22 Alvium G5-507m/c Pol, -508m/c, -508m/c Pol ........
  • Page 23 Software for your Alvium G5 ........
  • Page 24 Avoiding dropped packets ............. 205 Index Alvium G5/G5X User Guide V2.1.2...
  • Page 25: Document History And Conventions

    Document history and conventions This chapter includes: Document history ..............26 Conventions used in this user guide........34 Acronyms and terms ............. 35 Alvium G5/G5X User Guide V2.1.2...
  • Page 26: Document History

    • Fixed issues in Camera feature availability on page 136. Firmware version: 00.13.02.46198eb2 V2.1.1 2024-Jun-06 • Added notes for Alvium G5-831 and G5-832 that ROI frame rates have been calculated in Specifications on page 48. • Corrected typos. Release: Firmware version: 00.13.02.46198eb2 V2.1.0 2024-Jun-04 •...
  • Page 27 Lenses: Focal length vs. field of view on page 138: Added models coming soon: Alvium G5-320 VSWIR, -507 Pol, and -530 VSWIR. Updated data for G5-508 Pol )G5-508c Pol is coming soon(. Aligned sensor size values to 1 decimal place.
  • Page 28 Pol. • Updated Camera feature availability on page 136. Firmware version: 00.12.00.00611a22 V1.7.0 2023-Nov-07 • Added Alvium G5-508 Pol in Alvium G5/G5X model specifications on page 60 and in Focal length versus field of view on page 140. Firmware version: 00.12.00.00611a22 V1.6.1...
  • Page 29 140. Firmware version: 00.12.00.00611a22 V1.5.0 2023-Jul-12 • Renamed the title and contents from Alvium G5 to Alvium G5/G5X to include new G5X models. • Updates to Alvium G5/G5X model specifications on page 60: - Changed horizontal resolution for G5-510 and G5-511.
  • Page 30 60. • Corrected the width value in the specifications for Alvium G5-1620m/c on page 112. • Added Alvium G5-1242 and G5-2040 models in Alvium G5/G5X model specifications on page 60 Focal length versus field of view on page 140.
  • Page 31 • Replaced previous calculated values for ROI frame rates by measured values in Alvium G5/G5X model specifications on page 60. • Added Alvium G5-510 models in Alvium G5/G5X model specifications on page 60 and Focal length versus field of view on page 140.
  • Page 32 60: Adjusted values for bandwidth in Factors for exposure time and frame rates on page 53. Removed data for Alvium G5-030 VSWIR from, also in Focal length versus field of view page 140. Corrected max. gain for Alvium G5-130 VSWIR to 42 dB.
  • Page 33 Document history and conventions Version Date Remarks Release: Firmware version: 00.10.00.6c9062b1 V1.1.0 2022-Jul-20 • Replaced notes to inquire with Allied Vision Sales representatives by download links to the Allied Vision website. • Added Camera identification on page 38, including Model ID for DoC assignment.
  • Page 34: Conventions Used In This User Guide

    Risk of cuts by sharp edges of lens mounts Precautions are described NOTICE Material damage or violation of data security Precautions are described. Practical Tip Additional information helps to understand or ease handling the camera. Alvium G5/G5X User Guide V2.1.2...
  • Page 35: Acronyms And Terms

    Horizontal × Vertical )sensor resolution( KByte Kilobyte MByte Megabyte MByte/s Megabyte per second Megapixels )see P( N.a. Not applicable )in tables( Network interface card Pixels )see MP( Power sourcing equipment Table 4: Acronyms and terms (sheet 1 of 2) Alvium G5/G5X User Guide V2.1.2...
  • Page 36 )RS( and global release shutter )GRS( shutter type Sensor specific readout, such as rolling shutter )RS( or global shutter )GS( S-Mount M12-Mount Transmission Control Protocol User Datagram Protocol Table 4: Acronyms and terms (sheet 2 of 2) Alvium G5/G5X User Guide V2.1.2...
  • Page 37: Compliance, Safety, And Intended Use

    Compliance, safety, and intended use This chapter includes: Camera identification............38 Compliance notifications ............38 Intended use ................. 40 Copyright and trademarks ............ 41 Your safety................41 Product safety ............... 43 Alvium G5/G5X User Guide V2.1.2...
  • Page 38: Camera Identification

    MAC address Product code Serial number Closed housing Alvium G5/G5X cameras have the Model ID: A1F. Compliance notifications The following variants of closed housing Alvium G5 cameras )model ID: A 1 F( are KC certified: 030 VSWIR 203m/c 500m/c 511m/c...
  • Page 39: For Customers In The Us

    • Consult the dealer or an experienced radio/TV technician for help. Supplier Declaration of Conformity Alvium G5/G5X cameras comply with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2.
  • Page 40: For Customers In Canada

    We are offering standard products as well as customized solutions. Intended use of Allied Vision product is the integration into Vision systems by professionals. All Allied Vision product is sold in a B2B setting.
  • Page 41: Copyright And Trademarks

    However, especially when operated in higher ambient temperatures, additional measures for heat dissipation, such as using a heat sink, should be considered. If you have doubts or questions, please feel free to contact your Allied Vision Sales representative for support! If the mainboard temperature exceeds the specified maximum for more than two seconds, the camera is powered off automatically.
  • Page 42: Camera Mounting

    For a suitable heat sink, see www.alliedvision.com/en/support/ accessory-documentation. For more information on heat dissipation, see the Optimum Heat Dissipation for Alvium G5/G5X Cameras application note: www.alliedvision.com/en/support/ technical-documentation/alvium-gige-documentation. Camera mounting Cameras must be mounted using the mounting threads. If vibration is higher than specified, cameras can disconnect from the mounting.
  • Page 43: Product Safety

    • Only use power supplies that meet the insulation requirement according to PELV or SELV. For details, please refer to IEC 61140. • If using external power supplies by third-party manufacturers, observe polarity to avoid damage to the camera electronics. Alvium G5/G5X User Guide V2.1.2...
  • Page 44 5GBASE-T NICs To avoid damage to 5GBASE-T NICs and injectors, make sure that PoE power sourcing equipment is at least compliant to IEEE 802.3af. 5GBASE-T accessories For Accessories, such as interface cables and cards, see www.alliedvision.com/en/support/accessory-documentation. Alvium G5/G5X User Guide V2.1.2...
  • Page 45: Optical Components

    Sensors are sensitive to excessive radiation: focused sunlight, UV light, lasers, and X-rays can damage the sensor. Dirt and scratches can damage the sensor as well. Alvium G5/G5X cameras do not need additional cleaning. Cameras are cleaned before shipping. Incorrect cleaning can damage the sensor or the filter. Therefore, never clean the sensor or the filter.
  • Page 46 Advanced sensor cleanliness If standard definitions for Alvium do not fulfill the requirements of your application, please contact your Allied Vision Sales representative or visit www.alliedvision.com/en/about-us/contact-us/technical-support-repair-/-rma. Lenses Maximum protrusion The sensor, filter, or lens can be damaged if a lens exceeding maximum protrusion is mounted to the camera.
  • Page 47: Mechanical Components

    • Adhere to the instructions and safety notes provided by the manufacturer of the conductive media. • Ensure that the conductive media is correctly positioned: covering only the components to be cooled. Alvium G5/G5X User Guide V2.1.2...
  • Page 48: Specifications

    Specifications This chapter includes: Applied standards ..............49 Notes on specifications............51 Alvium G5/G5X model specifications ........60 White balance default............127 Dimensions and mass ............128 Technical drawings .............. 128 Lens mounts and maximum protrusion ......131 IR cut filter................132 Sensor position accuracy ............
  • Page 49: Applied Standards

    Alvium G5X cameras add TCP based operation, using GigE Vision standard extended by a custom TCP protocol. IP class Equipped with a lens as intended, Alvium G5/G5X cameras comply with IP40 class according to IEC 60529. Shock and vibration Alvium G5/G5X cameras were tested successfully according to the following standards: •...
  • Page 50 Sweep duration per axis [hh:mm:ss] 03:45:40 Number of sweeps For technical reasons, all three axes are tested with the shaker in the upright position without a sliding table. Table 10: Other parameters for IEC 60068-2-6 tests Alvium G5/G5X User Guide V2.1.2...
  • Page 51: Notes On Specifications

    Measurements for QE and spectral response Curves for quantum efficiency and for relative response show manufacturer data that has been adapted by Allied Vision’s measurements according to EMVA 1288. In some cases, no such measurements may be available. This is signaled by table captions saying According to manufacturer data.
  • Page 52: Exposure Time And Frame Rates

    Values for exposure time ranges were measured with FW V00.12.00.00611a22. Minimum exposure times with FW V00.13.00.71d891fe have been reduced for all Alvium G5/G5X models, except for Alvium G5-500, G5 -1240, and G5/G5X-2050. Measurements will be published in a future version of this document.
  • Page 53 • The camera is operated in triggered mode • Low bandwidth is used • Small ROIs are used. Factors for exposure time and frame rates • The default bandwidth for Alvium G5/G5X cameras is 625 MByte/s, the available maximum. DeviceLinkThroughputLimit has a default value of 115 MByte/s, but it is disabled.
  • Page 54: Triggering And Sensor Shutter Types

    Specifications By default, Alvium G5/G5X models use the maximum bit depth for . For selected models, mode switches automatically SensorBitDepth Adaptive between 12-bit and 10-bit sensor ADC readout, depending on the selected pixel format’s bit depth. This allows to reduce bandwidth and increase frame rates when only 10-bit is required.
  • Page 55 • Your individual setup may cause delays in data transmission. Bandwidth adjustments Consider the bandwidth available for camera payload depends on your individual hardware, the operating system, software and drivers, and your application. We recommend you to adjust DeviceLinkThroughputLimit to your requirements. Alvium G5/G5X User Guide V2.1.2...
  • Page 56: Brightness With G5-812 Uv Cameras

    The brightness level increases from the bottom to the top of the image. Digital binning Alvium G5/G5X cameras combine digital horizontal binning and digital vertical binning, for integer values 1 to 8. Alvium G5/G5X models ≥12 MP resolution If digital horizontal and digital vertical binning are set to 1×...
  • Page 57: Multiple Regions

    Specifications Multiple regions All Alvium G5/G5X models support single ROI )region of interest(. Because multiple ROI ) features( are sensor based, it is not supported by all MultipleRegions camera models. With all the corresponding models, Free mode is available for with 1 to 4 subregions.
  • Page 58 Available subregion resolutions Table 16 shows the available total pixel resolutions when multiple regions are enabled. How are these values applied? Alvium G5-2460 supports 1 to 4 subregions in Horizontal mode. Example Subregions could be 608 × 8, 608 × 8, 2048 × 8, and 1920 × 8, with a minimum width of 608 pixels per subregion and a minimum height of 8 pixels.
  • Page 59: Operation For Typical Power Consumption

    • Sensor ADC readout using maximum bit depth • Without bandwidth limitations. Dimensions and mass For your model’s dimensions, see Dimensions and mass on page 128. For technical drawings, see Technical drawings on page 128. Alvium G5/G5X User Guide V2.1.2...
  • Page 60: Alvium G5/G5X Model Specifications

    -20 °C to +60 °C )Housing(, -20 °C to +85 °C )Mainboard Humidity 0% to 80% humidity )non-condensing( Digital interface 5GBASE-T, 2.5GBASE-T, 1000BASE-T Camera controls GenICam )GenICam Access( Output by DeviceTemperature Table 17: Alvium G5-052m/c specifications Alvium G5/G5X User Guide V2.1.2...
  • Page 61 The three dots... represent the colors of a Bayer pixel format, such as in BayerRG8. The SensorBitDepth value must be set separately from PixelFormat. Sensor ADC readout modes for maximum frame rates on page 53 for details. Table 18: Alvium G5-052m/c ROI frame rates Alvium G5/G5X User Guide V2.1.2...
  • Page 62: Alvium G5-130 Vswir

    -20 °C to +60 °C )Housing(, -20 °C to +85 °C )Mainboard Humidity 0% to 80% humidity )non-condensing( Digital interface 5GBASE-T, 2.5GBASE-T, 1000BASE-T Camera controls GenICam )GenICam Access( Output by DeviceTemperature Table 19: Alvium G5-130 VSWIR specifications Alvium G5/G5X User Guide V2.1.2...
  • Page 63 Specifications Absolute QE Sony IMX990, IMX991 absolute QE 1000 1100 1200 1300 1400 1500 1600 1700 1800 Wavelength [nm] Figure 4: Alvium G5-130m SWIR (Sony IMX990) absolute QE Alvium G5/G5X User Guide V2.1.2...
  • Page 64 Mono12 or at SensorBitDepth = 12-Bit The SensorBitDepth value must be set separately from PixelFormat. Sensor ADC readout modes for maximum frame rates on page 53 for details. Table 20: Alvium G5-130m SWIR ROI frame rates Alvium G5/G5X User Guide V2.1.2...
  • Page 65: Alvium G5-203M/C

    -20 °C to +60 °C )Housing(, -20 °C to +85 °C )Mainboard Humidity 0% to 80% humidity )non-condensing( Digital interface 5GBASE-T, 2.5GBASE-T, 1000BASE-T Camera controls GenICam )GenICam Access( Output by DeviceTemperature Table 21: Alvium G5-203m/c specifications Alvium G5/G5X User Guide V2.1.2...
  • Page 66 The three dots... represent the colors of a Bayer pixel format, such as in BayerRG8. The SensorBitDepth value must be set separately from PixelFormat. Sensor ADC readout modes for maximum frame rates on page 53 for details. Table 22: Alvium G5-203m/c ROI frame rates Alvium G5/G5X User Guide V2.1.2...
  • Page 67: Alvium G5-240M/C

    -20 °C to +60 °C )Housing(, -20 °C to +85 °C )Mainboard Humidity 0% to 80% humidity )non-condensing( Digital interface 5GBASE-T, 2.5GBASE-T, 1000BASE-T Camera controls GenICam )GenICam Access( Output by DeviceTemperature Table 23: Alvium G5-240m/c specifications Alvium G5/G5X User Guide V2.1.2...
  • Page 68 Absolute QE Blue QE Green QE Red QE Monochrome QE Sony IMX392 absolute QE 1000 Wavelength [nm] Figure 5: Alvium G5-240m/c (Sony IMX392) absolute QE Spectral response Blue Response Green Response Red Response Monochrome Response 0.4000 Sony IMX392 spectral response 0.3000...
  • Page 69 The three dots... represent the colors of a Bayer pixel format, such as in BayerRG8. The SensorBitDepth value must be set separately from PixelFormat. Sensor ADC readout modes for maximum frame rates on page 53 for details. Table 24: Alvium G5-240m/c ROI frame rates Alvium G5/G5X User Guide V2.1.2...
  • Page 70: Alvium G5-291M/C

    -20 °C to +60 °C )Housing(, -20 °C to +85 °C )Mainboard Humidity 0% to 80% humidity )non-condensing( Digital interface 5GBASE-T, 2.5GBASE-T, 1000BASE-T Camera controls GenICam )GenICam Access( Output by DeviceTemperature Table 25: Alvium G5-291m/c specifications Alvium G5/G5X User Guide V2.1.2...
  • Page 71 The three dots... represent the colors of a Bayer pixel format, such as in BayerRG8. The SensorBitDepth value must be set separately from PixelFormat. Sensor ADC readout modes for maximum frame rates on page 53 for details. Table 26: Alvium G5-291m/c ROI frame rates Alvium G5/G5X User Guide V2.1.2...
  • Page 72: Alvium G5-320 Vswir )Coming Soon

    -20 °C to +60 °C )Housing(, -20 °C to +85 °C )Mainboard Humidity 0% to 80% humidity )non-condensing( Digital interface 5GBASE-T, 2.5GBASE-T, 1000BASE-T Camera controls GenICam )GenICam Access( Output by DeviceTemperature Table 27: Alvium G5-320 VSWIR specifications Alvium G5/G5X User Guide V2.1.2...
  • Page 73 1400 1500 1600 1700 1800 Wavelength [nm] Figure 7: Alvium G5-320 VSWIR (Sony IMX993) absolute QE According to manufacturer data Spectral response We intend to add a diagram in a future version of this document. Alvium G5/G5X User Guide V2.1.2...
  • Page 74 The three dots... represent the colors of a Bayer pixel format, such as in BayerRG8. The SensorBitDepth value must be set separately from PixelFormat. Sensor ADC readout modes for maximum frame rates on page 53 for details. Table 28: Alvium G5-320 VSWIR ROI frame rates (calculated values) Alvium G5/G5X User Guide V2.1.2...
  • Page 75: Alvium G5-500M/C

    -20 °C to +60 °C )Housing(, -20 °C to +85 °C )Mainboard Humidity 0% to 80% humidity )non-condensing( Digital interface 5GBASE-T, 2.5GBASE-T, 1000BASE-T Camera controls GenICam )GenICam Access( In triggered mode: ~34 fps Output by DeviceTemperature Table 29: Alvium G5-500m/c specifications Alvium G5/G5X User Guide V2.1.2...
  • Page 76 Red QE Monochrome QE 100% ON Semi AR0521 absolute QE 1000 1050 1100 Wavelength [nm] Figure 8: Alvium G5-500m/c (ON Semi AR0521) absolute QE Spectral response Blue Response Green Response Red Response Monochrome Response 0.400 ON Semi AR0521 spectral response 0.350...
  • Page 77 SensorBitDepth = 10-Bit / Mono10 or Bayer...10 at SensorBitDepth = 10 -Bit The three dots... represent the colors of a Bayer pixel format, such as in BayerRG8. Table 31: Alvium G5-500m/c ROI frame rates Alvium G5/G5X User Guide V2.1.2...
  • Page 78: Alvium G5-507M/C Pol

    12 to 24 VDC Power requirements )PoE( IEEE 802.3af Power consumption )typical( External power: 5.5 W at 12 VDC | Power over Ethernet: 5.9 W Table 32: Alvium G5-507m/c Pol specifications (sheet 1 of 2) Alvium G5/G5X User Guide V2.1.2...
  • Page 79 5GBASE-T, 2.5GBASE-T, 1000BASE-T Camera controls GenICam )GenICam Access( Output by DeviceTemperature Table 32: Alvium G5-507m/c Pol specifications (sheet 2 of 2) Absolute QE, spectral response We intend to add diagrams in a future version of this document. Alvium G5/G5X User Guide V2.1.2...
  • Page 80 The three dots... represent the colors of a Bayer pixel format, such as in BayerRG8. The SensorBitDepth value must be set separately from PixelFormat. Sensor ADC readout modes for maximum frame rates on page 53 for details. Table 33: Alvium G5-507m/c Pol ROI frame rates Alvium G5/G5X User Guide V2.1.2...
  • Page 81: Alvium G5-508M/C

    -20 °C to +60 °C )Housing(, -20 °C to +85 °C )Mainboard Humidity 0% to 80% humidity )non-condensing( Digital interface 5GBASE-T, 2.5GBASE-T, 1000BASE-T Camera controls GenICam )GenICam Access( Output by DeviceTemperature Table 34: Alvium G5-508m/c specifications Alvium G5/G5X User Guide V2.1.2...
  • Page 82 Absolute QE Blue QE Green QE Red QE Monochrome QE Sony IMX250 absolute QE 1000 Wavelength [nm] Figure 10: Alvium G5-508m/c (Sony IMX250) absolute QE Spectral response Blue Response Green Response Red Response Monochrome Response 0.4000 Sony IMX250 spectral response 0.3000...
  • Page 83 The three dots... represent the colors of a Bayer pixel format, such as in BayerRG8. The SensorBitDepth value must be set separately from PixelFormat. Sensor ADC readout modes for maximum frame rates on page 53 for details. Table 35: Alvium G5-508m/c ROI frame rates Alvium G5/G5X User Guide V2.1.2...
  • Page 84: Alvium G5-508M/C Pol

    1024 KByte Inputs and outputs 1 opto-isolated input, 1 opto-isolated output, 2 non-isolated GPIOs Power requirements 12 to 24 VDC Power requirements )PoE( IEEE 802.3af Table 36: Alvium G5-508m/c Pol specifications (sheet 1 of 2) Alvium G5/G5X User Guide V2.1.2...
  • Page 85 5GBASE-T, 2.5GBASE-T, 1000BASE-T Camera controls GenICam )GenICam Access( Output by DeviceTemperature Table 36: Alvium G5-508m/c Pol specifications (sheet 2 of 2) Absolute QE, spectral response We intend to add diagrams in a future version of this document. Alvium G5/G5X User Guide V2.1.2...
  • Page 86 The three dots... represent the colors of a Bayer pixel format, such as in BayerRG8. The SensorBitDepth value must be set separately from PixelFormat. Sensor ADC readout modes for maximum frame rates on page 53 for details. Table 37: Alvium G5-508m/c Pol ROI frame rates Alvium G5/G5X User Guide V2.1.2...
  • Page 87: Alvium G5-510M/C

    -20 °C to +60 °C )Housing(, -20 °C to +85 °C )Mainboard Humidity 0% to 80% humidity )non-condensing( Digital interface 5GBASE-T, 2.5GBASE-T, 1000BASE-T Camera controls GenICam )GenICam Access( Output by DeviceTemperature Table 38: Alvium G5-510m/c specifications Alvium G5/G5X User Guide V2.1.2...
  • Page 88 Absolute QE Blue QE Green QE Red QE Monochrome QE Sony IMX54x absolute QE 1000 Wavelength [nm] Figure 12: Alvium G5-510m/c (Sony IMX548) absolute QE Spectral response Blue Response Green Response Red Response Monochrome Response 0.4000 Sony IMX54x spectral response 0.3000...
  • Page 89 SensorBitDepth =12-Bit / Mono8 or Bayer...8 Mono12 or Bayer...12 at SensorBitDepth = 12-Bit The three dots... represent the colors of a Bayer pixel format, such as in BayerRG8. Table 39: Alvium G5-510m/c ROI frame rates Alvium G5/G5X User Guide V2.1.2...
  • Page 90: Alvium G5-511M/C

    -20 °C to +60 °C )Housing(, -20 °C to +85 °C )Mainboard Humidity 0% to 80% humidity )non-condensing( Digital interface 5GBASE-T, 2.5GBASE-T, 1000BASE-T Camera controls GenICam )GenICam Access( Output by DeviceTemperature Table 40: Alvium G5-511m/c specifications Alvium G5/G5X User Guide V2.1.2...
  • Page 91 Absolute QE Blue QE Green QE Red QE Monochrome QE Sony IMX54x absolute QE 1000 Wavelength [nm] Figure 14: Alvium G5-511m/c (Sony IMX547) absolute QE Spectral response Blue Response Green Response Red Response Monochrome Response 0.4000 Sony IMX54x spectral response 0.3000...
  • Page 92 SensorBitDepth =12-Bit / Mono8 or Bayer...8 Mono12 or Bayer...12 at SensorBitDepth = 12-Bit The three dots... represent the colors of a Bayer pixel format, such as in BayerRG8. Table 41: Alvium G5-511m/c ROI frame rates Alvium G5/G5X User Guide V2.1.2...
  • Page 93: Alvium G5-530 Vswir

    -20 °C to +60 °C )Housing(, -20 °C to +85 °C )Mainboard Humidity 0% to 80% humidity )non-condensing( Digital interface 5GBASE-T, 2.5GBASE-T, 1000BASE-T Camera controls GenICam )GenICam Access( Output by DeviceTemperature Table 42: Alvium G5-530 VSWIRspecifications Alvium G5/G5X User Guide V2.1.2...
  • Page 94 1400 1500 1600 1700 1800 Wavelength [nm] Figure 16: Alvium G5-530 VSWIR (Sony IMX992) absolute QE According to manufacturer data Spectral response We intend to add a diagram in a future version of this document. Alvium G5/G5X User Guide V2.1.2...
  • Page 95 The three dots... represent the colors of a Bayer pixel format, such as in BayerRG8. The SensorBitDepth value must be set separately from PixelFormat. Sensor ADC readout modes for maximum frame rates on page 53 for details. Table 43: Alvium G5-530 VSWIR ROI frame rates Alvium G5/G5X User Guide V2.1.2...
  • Page 96: Alvium G5-811M/C

    -20 °C to +60 °C )Housing(, -20 °C to +85 °C )Mainboard Humidity 0% to 80% humidity )non-condensing( Digital interface 5GBASE-T, 2.5GBASE-T, 1000BASE-T Camera controls GenICam )GenICam Access( Output by DeviceTemperature Table 44: Alvium G5-811m/c specifications Alvium G5/G5X User Guide V2.1.2...
  • Page 97 Absolute QE Blue QE Green QE Red QE Monochrome QE Sony IMX54x absolute QE 1000 Wavelength [nm] Figure 17: Alvium G5-811m/c (Sony IMX546) absolute QE Spectral response Blue Response Green Response Red Response Monochrome Response 0.4000 Sony IMX54x spectral response 0.3000...
  • Page 98 SensorBitDepth = 12-Bit / Mono8 or Bayer...8 Mono12 or Bayer...12 at SensorBitDepth = 12-Bit The three dots... represent the colors of a Bayer pixel format, such as in BayerRG8. Table 45: Alvium G5-811m/c ROI frame rates Alvium G5/G5X User Guide V2.1.2...
  • Page 99: Alvium G5-812 Uv

    -20 °C to +60 °C )Housing(, -20 °C to +85 °C )Mainboard Humidity 0% to 80% humidity )non-condensing( Digital interface 5GBASE-T, 2.5GBASE-T, 1000BASE-T Camera controls GenICam )GenICam Access( Output by DeviceTemperature Table 46: Alvium G5-812 UV specifications Alvium G5/G5X User Guide V2.1.2...
  • Page 100 Absolute QE Monochrome QE Sony IMX487 absolute QE 1000 Wavelength [nm] Figure 19: Alvium G5-812 UV (Sony IMX487) absolute QE Spectral response We intend to add a diagram in a future version of this document. Alvium G5/G5X User Guide V2.1.2...
  • Page 101 SensorBitDepth = 12-Bit / Mono8 or Bayer...8 Mono12 or Bayer...12 at SensorBitDepth = 12-Bit The three dots... represent the colors of a Bayer pixel format, such as in BayerRG8. Table 47: Alvium G5-812 UV ROI frame rates Alvium G5/G5X User Guide V2.1.2...
  • Page 102: Alvium G5-831M/C )Coming Soon

    -20 °C to +60 °C )Housing(, -20 °C to +85 °C )Mainboard Humidity 0% to 80% humidity )non-condensing( Digital interface 5GBASE-T, 2.5GBASE-T, 1000BASE-T Camera controls GenICam )GenICam Access( In triggered mode: ~59 fps Output by DeviceTemperature Table 48: Alvium G5-831m/c specifications Alvium G5/G5X User Guide V2.1.2...
  • Page 103 Mono8 or Bayer...8 Mono10 or Bayer...10 at SensorBitDepth = 10 -Bit The three dots... represent the colors of a Bayer pixel format, such as in BayerRG8. Table 50: Alvium G5-831m/c ROI frame rates (calculated values) Alvium G5/G5X User Guide V2.1.2...
  • Page 104: Alvium G5-832M/C )Coming Soon

    -20 °C to +60 °C )Housing(, -20 °C to +85 °C )Mainboard Humidity 0% to 80% humidity )non-condensing( Digital interface 5GBASE-T, 2.5GBASE-T, 1000BASE-T Camera controls GenICam )GenICam Access( In triggered mode: ~49 fps Output by DeviceTemperature Table 51: Alvium G5-832m/c specifications Alvium G5/G5X User Guide V2.1.2...
  • Page 105 Mono8 or Bayer...8 Mono10 or Bayer...10 at SensorBitDepth = 12 -Bit The three dots... represent the colors of a Bayer pixel format, such as in BayerRG8. Table 53: Alvium G5-832m/c ROI frame rates (calculated values) Alvium G5/G5X User Guide V2.1.2...
  • Page 106: Alvium G5-1240M/C

    5GBASE-T, 2.5GBASE-T, 1000BASE-T Camera controls GenICam )GenICam Access( In triggered mode: ~41 fps Digital vertical binning can be used only when digital horizontal binning is used as well. Output by DeviceTemperature Table 54: Alvium G5-1240m/c specifications Alvium G5/G5X User Guide V2.1.2...
  • Page 107 Absolute QE Blue QE Green QE Red QE Monochrome QE Sony IMX226 absolute QE 1000 Wavelength [nm] Figure 20: Alvium G5-1240m/c (Sony IMX226) absolute QE Spectral response Blue Response Green Response Red Response Monochrome Response 0.4000 Sony IMX226 spectral response 0.3000...
  • Page 108 SensorBitDepth = 10-Bit / Mono8 or Bayer...8 Mono10 or Bayer...10 at SensorBitDepth = 10 -Bit The three dots... represent the colors of a Bayer pixel format, such as in BayerRG8. Table 56: Alvium G5-1240m/c ROI frame rates Alvium G5/G5X User Guide V2.1.2...
  • Page 109: Alvium G5-1242M/C

    0% to 80% humidity )non-condensing( Digital interface 5GBASE-T, 2.5GBASE-T, 1000BASE-T Camera controls GenICam )GenICam Access( Digital vertical binning can be used only when digital horizontal binning is used as well. Output by DeviceTemperature Table 57: Alvium G5-1242m/c specifications Alvium G5/G5X User Guide V2.1.2...
  • Page 110 Absolute QE Blue QE Green QE Red QE Monochrome QE Sony IMX54x absolute QE 1000 Wavelength [nm] Figure 22: Alvium G5-1242m/c (Sony IMX545) absolute QE Spectral response Blue Response Green Response Red Response Monochrome Response 0.4000 Sony IMX54x spectral response 0.3000...
  • Page 111 SensorBitDepth = 12-Bit / Mono8 or Bayer...8 Mono12 or Bayer...12 at SensorBitDepth = 12-Bit The three dots... represent the colors of a Bayer pixel format, such as in BayerRG8. Table 58: Alvium G5-1242m/c ROI frame rates Alvium G5/G5X User Guide V2.1.2...
  • Page 112: Alvium G5-1620M/C

    0% to 80% humidity )non-condensing( Digital interface 5GBASE-T, 2.5GBASE-T, 1000BASE-T Camera controls GenICam )GenICam Access( Digital vertical binning can be used only when digital horizontal binning is used as well. Output by DeviceTemperature Table 59: Alvium G5-1620m/c specifications Alvium G5/G5X User Guide V2.1.2...
  • Page 113 Absolute QE Blue QE Green QE Red QE Monochrome QE Sony IMX54x absolute QE 1000 Wavelength [nm] Figure 24: Alvium G5-1620m/c (Sony IMX542) absolute QE Spectral response Blue Response Green Response Red Response Monochrome Response 0.4000 Sony IMX54x spectral response 0.3000...
  • Page 114 SensorBitDepth = 12-Bit / Mono8 or Bayer...8 Mono12 or Bayer...12 at SensorBitDepth = 12-Bit The three dots... represent the colors of a Bayer pixel format, such as in BayerRG8. Table 60: Alvium G5-1620m/c ROI frame rates Alvium G5/G5X User Guide V2.1.2...
  • Page 115: Alvium G5-2040M/C

    0% to 80% humidity )non-condensing( Digital interface 5GBASE-T, 2.5GBASE-T, 1000BASE-T Camera controls GenICam )GenICam Access( Digital vertical binning can be used only when digital horizontal binning is used as well. Output by DeviceTemperature Table 61: Alvium G5-2040m/c specifications Alvium G5/G5X User Guide V2.1.2...
  • Page 116 Absolute QE Blue QE Green QE Red QE Monochrome QE Sony IMX54x absolute QE 1000 Wavelength [nm] Figure 26: Alvium G5-2040m/c (Sony IMX541) absolute QE Spectral response Blue Response Green Response Red Response Monochrome Response 0.4000 Sony IMX54x spectral response 0.3000...
  • Page 117 SensorBitDepth = 12-Bit / Mono8 or Bayer...8 Mono12 or Bayer...12 at SensorBitDepth = 12-Bit The three dots... represent the colors of a Bayer pixel format, such as in BayerRG8. Table 62: Alvium G5-2040m/c ROI frame rates Alvium G5/G5X User Guide V2.1.2...
  • Page 118: Alvium G5/G5X-2050M/C

    Specifications Alvium G5/G5X-2050m/c Firmware version for Alvium G5X models While Alvium G5 models are supported by the latest firmware version, Alvium G5X models require FW 00.12.00.00611a22. A future common firmware version will support G5 and G5X. Specification Feature G5/G5X-2050m (monochrome)
  • Page 119 G5X: -20 °C to +55 °C )Housing(, -20 °C to +88 °C )Mainboard Humidity 0% to 80% humidity )non-condensing( Digital interface 5GBASE-T, 2.5GBASE-T, 1000BASE-T Camera controls GenICam )GenICam Access( Output by DeviceTemperature Table 63: Alvium G5/G5X-2050m/c specifications (sheet 2 of 2) Alvium G5/G5X User Guide V2.1.2...
  • Page 120 Absolute QE Blue QE Green QE Red QE Monochrome QE Sony IMX183 absolute QE 1000 Wavelength [nm] Figure 28: Alvium G5/G5X-2050m/c (Sony IMX183) absolute QE Spectral response Blue Response Green Response Red Response Monochrome Response 0.4000 Sony IMX183 spectral response 0.3000...
  • Page 121 SensorBitDepth = 10-Bit / Mono8 or Bayer...8 Mono10 or Bayer...10 at SensorBitDepth = 10 -Bit The three dots... represent the colors of a Bayer pixel format, such as in BayerRG8. Table 65: Alvium G5/G5X-2050m/c ROI frame rates Alvium G5/G5X User Guide V2.1.2...
  • Page 122: Alvium G5/G5X-2460M/C

    Specifications Alvium G5/G5X-2460m/c Firmware version for Alvium G5X models While Alvium G5 models are supported by the latest firmware version, Alvium G5X models require FW 00.12.00.00611a22. A future common firmware version will support G5 and G5X. Specification Feature G5/G5X-2460m G5/G5X-2460c...
  • Page 123 G5X: -20 °C to +55 °C )Housing(, -20 °C to +85 °C )Mainboard Humidity 0% to 80% humidity )non-condensing( Digital interface 5GBASE-T, 2.5GBASE-T, 1000BASE-T Camera controls GenICam )GenICam Access( Output by DeviceTemperature Table 66: Alvium G5/G5X-2460m/c specifications (sheet 2 of 2) Alvium G5/G5X User Guide V2.1.2...
  • Page 124 Absolute QE Blue QE Green QE Red QE Monochrome QE Sony IMX54x absolute QE 1000 Wavelength [nm] Figure 30: Alvium G5/G5X-2460m/c (Sony IMX540) absolute QE Spectral response Blue Response Green Response Red Response Monochrome Response 0.4000 Sony IMX54x spectral response 0.3000...
  • Page 125 Mono8 or Bayer...8 Mono12 or Bayer...12 at SensorBitDepth = 12-Bit The three dots... represent the colors of a Bayer pixel format, such as in BayerRG8. Table 67: Alvium G5/G5X-2460m/c ROI frame rates (sheet 1 of 2) Alvium G5/G5X User Guide V2.1.2...
  • Page 126 Mono8 or Bayer...8 Mono12 or Bayer...12 at SensorBitDepth = 12-Bit The three dots... represent the colors of a Bayer pixel format, such as in BayerRG8. Table 67: Alvium G5/G5X-2460m/c ROI frame rates (sheet 2 of 2) Alvium G5/G5X User Guide V2.1.2...
  • Page 127: White Balance Default

    Specifications White balance default Alvium G5/G5X color cameras are balanced for neutral color reproduction with an illumination of 5000 °K )warm daylight(. Table 68 shows default values for the red and blue channel by model. For different illuminations, use auto white balance or adapt the color channel values manually.
  • Page 128: Dimensions And Mass

    ±0.3 ±0.1 M3 - 3 M3 - 2.5 (2x) 0.20 29.35 M2 - 2 (4x) 0.05 ±0.1 M2 - 4.5 (4x) C-Mount (1x32 TPI-UNS-2B) ±0.1 M3 - 2.5 (2x) Figure 32: Dimensions for C-Mount models Alvium G5/G5X User Guide V2.1.2...
  • Page 129: Cs-Mount

    ±0.1 M3 - 2.5 (2x) M3 - 3 0.20 M2 - 2 (4x) 29.35 0.05 ±0.1 ±0.1 M2 - 4.5 (4x) CS-Mount (1x32 TPI-UNS-2B) ±0.1 M3 - 2.5 (2x) Figure 33: Dimensions for CS-Mount models Alvium G5/G5X User Guide V2.1.2...
  • Page 130: S-Mount

    S-Mount ±0.3 ±0.1 M3 - 3 M3 - 2.5 (2x) 0.20 29.35 M2 - 2 (4x) 0.05 ±0.1 M2 - 4.5 (4x) S-Mount (M12x0.5) ±0.1 M3 - 2.5 (2x) Figure 34: Dimensions for S-Mount models Alvium G5/G5X User Guide V2.1.2...
  • Page 131: Lens Mounts And Maximum Protrusion

    Specifications Lens mounts and maximum protrusion No need to readjust lens mounts Alvium G5/G5X camera mounts are adjusted with high precision during manufacturing. Construction ensures permanent accuracy without need to readjust. Maximum protrusion Maximum protrusion C/CS-Mount S-Mount Filter Electronics Sensor...
  • Page 132: Ir Cut Filter

    Specifications IR cut filter The following table shows which Alvium G5/G5X models are equipped with an IR cut filter. The filter is permanently installed and cannot be removed. Color or monochrome model S-Mount CS-Mount C-Mount Color No filter Type Hoya C5000 IR cut filter...
  • Page 133: Sensor Position Accuracy

    We cannot measure or guarantee these values for S-Mount hardware options that are manufactured on customer request for: Alvium G5-052, -203, -291, -320 VSWIR, -507 Pol, -508, -508 Pol, -511, -530 VSWIR, -811, -812 UV, -832, -1242, -1620, -2040, G5/G5X-2050, G5/G5X-2460.
  • Page 134: Sensor Tilt

    2.74 µm × 2.74 µm 18 µm Alvium G5-2040m/c 2.74 µm × 2.74 µm 18 µm Alvium G5/G5X-2050m/c 2.4 µm × 2.4 µm 12 µm Alvium G5/G5X-2460m/c 2.74 µm × 2.74 µm 18 µm Table 73: Sensor tilt Alvium G5/G5X User Guide V2.1.2...
  • Page 135: User Sets

    Or they can be used to switch between different settings, for example, to adjust from daylight to artificial light. User sets on Alvium G5/G5X cameras support all features except for: • Selectors • Command features •...
  • Page 136: Camera Feature Availability

    G5-507 Pol, -508 Pol All, except for: ✔ ✔ G5-500, -831, Multiple ROI )regions of interest( -832, -1240, G5/G5X-2050 ✔ ✔ Reverse X/Y Table 75: Image control features by Alvium G5/G5X model (sheet 1 of 2) Alvium G5/G5X User Guide V2.1.2...
  • Page 137 All, except for: ✔ ✔ Sharpness/Blur G5-507 Pol, -508 Pol ✔ ✔ Single ROI )region of interest( Table 75: Image control features by Alvium G5/G5X model (sheet 2 of 2) Monochrome Color Camera control Supported models models models ✔ ✔...
  • Page 138: Lenses: Focal Length Vs. Field Of View

    Lenses: Focal length vs. field of view This chapter includes: About this chapter .............. 139 Optical vignetting with certain lenses ........ 139 About S-Mount lenses ............140 Focal length versus field of view......... 140 Alvium G5/G5X User Guide V2.1.2...
  • Page 139: About This Chapter

    Production spread causes tolerances for all values, including actual focal lengths. Calculations apply for image reproduction without distortion. Therefore, values do not apply for fisheye lenses. Please ask your Allied Vision Sales representative in case you need more information. Optical vignetting with certain lenses Lenses with short focal lengths may show optical vignetting at the edges of the image.
  • Page 140: About S-Mount Lenses

    Lenses: Focal length vs. field of view About S-Mount lenses Alvium G5/G5X S-Mount models have no filter. We recommend using S-Mount lenses with an integrated IR-cut filter for a better image quality. Read Mounting and focusing S-Mount lenses on page 155 to avoid damage when using S-Mount lenses.
  • Page 141: Alvium G5-130M Vswir

    187 × 156 61 × 51 129 × 107 Table 78: Focal length versus field of view for Alvium G5-130m VSWIR Alvium G5-203m/c Values for G5-203m/c cameras with Type 1/1.7 )9.2 mm diagonal( sensors: Field of view (H × V [mm])
  • Page 142: Alvium G5-240M/C

    185 × 116 60 × 38 127 × 80 Table 80: Focal length versus field of view for Alvium G5-240m/c Alvium G5-291m/c Values for G5-291m/c cameras with Type 2/3 )10.8 mm diagonal( sensors: Field of view (H × V in [mm])
  • Page 143: Alvium G5-320 Vswir

    136 × 101 41 × 30 89 × 66 Table 82: Focal length versus field of view for Alvium G5-320 VSWIR Alvium G5-500m/c Values for G5-500m/c cameras with Type 1/2.5 )7.1 mm diagonal( sensors: Field of view (H × V in [mm])
  • Page 144: Alvium G5-507M/C Pol, -508M/C, -508M/C Pol

    113 × 94 234 × 196 77 × 64 162 × 135 Table 84: Focal length versus field of view for Alvium G5-507m/c Pol, -508m/c, -508m/c Pol Alvium G5-510m/c, -511m/c Values for G5-510m/c and -511m/c cameras with Type 1/1.8 )8.8 mm diagonal( sensors: Field of view (H ×...
  • Page 145: Alvium G5-530 Vswir

    236 × 236 480 × 480 148 × 148 304 × 304 104 × 104 215 × 215 70 × 70 148 × 148 Table 87: Focal length versus field of view for Alvium G5-811m/c, -812 UV Alvium G5/G5X User Guide V2.1.2...
  • Page 146: Alvium G5-831M/C

    213 × 120 69 × 39 147 × 83 Table 88: Focal length versus field of view for Alvium G5-831m/c Alvium G5-832m/c Values for G5-832m/c cameras with Type 1/1.2 )12.9 mm diagonal( sensors: Field of view (H × V in [mm])
  • Page 147: Alvium G5-1240M/C

    215 × 157 441 × 321 150 × 109 312 × 227 102 × 74 215 × 157 64 × 47 139 × 102 Table 91: Focal length versus field of view for Alvium G5-1242m/c Alvium G5/G5X User Guide V2.1.2...
  • Page 148: Alvium G5-1620M/C

    277 × 158 83 × 47 180 × 103 Table 92: Focal length versus field of view for Alvium G5-1620m/c Alvium G5-2040m/c Values for G5-2040m/c cameras with Type 1.1 )17.5 mm diagonal( sensors: Field of view (H × V in [mm])
  • Page 149: Alvium G5/G5X-2050M/C

    277 × 240 569 × 492 194 × 168 403 × 348 131 × 114 277 × 240 83 × 72 180 × 156 Table 95: Focal length versus field of view for Alvium G5/G5X-2460m/c Alvium G5/G5X User Guide V2.1.2...
  • Page 150: Installing The Camera

    Mounting the heat sink............151 Mounting the camera ............152 Mounting the lens............... 154 Configuring the host computer .......... 158 Connecting to the host computer ........161 Powering up the camera............. 162 Software for your Alvium G5 ..........163 Alvium G5/G5X User Guide V2.1.2...
  • Page 151: Touching Hot Cameras

    Heat dissipation For a suitable heat sink, see www.alliedvision.com/en/support/ accessory-documentation. For more information on heat dissipation, see the Optimum Heat Dissipation for Alvium G5/G5X Cameras application note: www.alliedvision.com/en/support/ technical-documentation/alvium-gige-documentation. NOTICE Damage to the camera by heat sinks mounted improperly Adhere to the instructions and safety notes provided by the manufacturer of the heat sink.
  • Page 152: Mounting The Camera

    )C( of 2.7 mm between screws and mounting threads. b. Mounting thread b: At 0.51 Nm maximum torque for a thread engagement )C( of 2.2 mm between screws and mounting threads. 2. Continue with Mounting the lens on page 154. Alvium G5/G5X User Guide V2.1.2...
  • Page 153: Front Mounting

    Thread Length of thread Thread position Total protrusion Maximum torque group type engagement Front mounting 2 mm 1.7 mm 0.17 Nm 1.4 mm 0.14 Nm Front mounting 2 mm Table 96: Adjusting maximum torque values Alvium G5/G5X User Guide V2.1.2...
  • Page 154: Mounting The Lens

    For the Alvium G1 tripod adapter, see www.alliedvision.com/en/support/ accessory-documentation. Mounting the lens Observe the following notes before you mount lenses to Alvium G5/G5X cameras. CAUTION Injury by falling cameras or lenses A falling camera or lens can cause injury. • Ensure proper mounting of cameras and lenses, especially for dynamic applications.
  • Page 155: Mounting And Focusing S-Mount Lenses

    Installing the camera Mounting and focusing S-Mount lenses Allied Vision S-Mount lenses For technical data of Allied Vision S-Mount lenses with dedicated operating instructions, see the S-Mount Lenses User Guide at www.alliedvision.com/fileadmin/content/documents/products/accessories/lenses /Allied_Vision/User_Guide/S-Mount-Lenses_User-Guide.pdf. This section instructs how to use S-Mount lenses with your camera safely. S-Mount lenses are screwed into the mount to adjust focus.
  • Page 156 5. Checking (a) with a gauge, slowly screw the lens clockwise into the lens mount until the image is roughly in focus. 6. Slowly screw the lens in and out until you have found most accurate focus. Figure 45: Adjusting focus Alvium G5/G5X User Guide V2.1.2...
  • Page 157 If focus is constant over the image plane, you are done. If focus varies over the image plane, the lens is tilted. Continue with 10. Loosen the fixing nut. 11. Continue with The lens is locked in focus and ready for operation. Alvium G5/G5X User Guide V2.1.2...
  • Page 158: Configuring The Host Computer

    - Fixed Link Speed: If you set a link speed not supported by the camera, the link is not negotiated. Alvium G5/G5X cameras support 5 Gbit/s for full performance or 1 Gbit/s for host systems that do not support 5 Gbit/s.
  • Page 159: Ip Settings

    255.255.255.0 Blank Camera 3 connected to NIC 2 192.168.101.3 255.255.255.0 Blank Table 97: Static IP addresses for NICs and connected cameras Applying advanced IP settings for cameras Configuring IP settings on page 161 for instructions. Alvium G5/G5X User Guide V2.1.2...
  • Page 160: Adjusting The Nic Driver Settings

    Table 98: NIC settings Default packet size At startup, Alvium G5/G5X cameras have a default packet size of 576 bytes on the device stream channel. This enables optimum backward compatibility when ancient network hardware is used or when the network packets are tunneled through other protocols.
  • Page 161: Connecting To The Host Computer

    Installing the camera Connecting to the host computer Use a Category 6 or higher rated Ethernet cable to connect the Alvium G5/G5X camera to the NIC. Crossover cabling is not required but does work. The camera has circuitry to determine if a crossover cable is being used.
  • Page 162: Powering Up The Camera

    External power supply For a suitable external power supply, see www.alliedvision.com/en/support/ accessory-documentation. Powering the camera via PoE Please note the following when using PoE NICs and PoE injectors with Allied Vision PoE-capable Alvium G5/G5X cameras: Feature Specification Supported standard IEEE 802.3af, Power Class 0 Cable category We recommend you to use Category 6 cables for better performance.
  • Page 163: Software For Your Alvium G5

    Installing the camera Software for your Alvium G5 Allied Vision software Software packages provided by Allied Vision are free of charge and contain such as: • Drivers • SDK for camera control and image acquisition • Examples based on the provided APIs of the SDK •...
  • Page 164: Camera Interfaces

    Camera interfaces This chapter includes: I/Os: Precautions..............165 Back panel ................166 I/O connector pin assignment ..........167 I/Os and GPIOs ..............168 Status LEDs ................173 Alvium G5/G5X User Guide V2.1.2...
  • Page 165: I/Os: Precautions

    Camera interfaces I/Os: Precautions NOTICE Damage by reverse polarity If Alvium G5/G5X cameras are externally powered with reverse polarity, the cameras can be damaged. Power Alvium G5/G5X cameras according to the specifications described in this chapter. NOTICE Damage by serial communication voltage levels...
  • Page 166: Back Panel

    I/O connector The I/O connector is 10-pin TFM connector type TFM-105-02-L-DH. We recommend using cables by Allied Vision. If you are going to manufacture your own cables, see SFSD, ISDF, or SFM series at www.samtec.com. Even though the TFM connectors’ product naming differs between Alvium G1 and Alvium G5, both cameras use the same mating connectors.
  • Page 167: I/O Connector Pin Assignment

    )low( = 0 to 0.4 VDC )high( = 2.4 to 3.3 VDC at max. 20 mA GPIO1 See Pin 7, GPIO0 Reserved C-GND 0 VDC Chassis ground and shielding Table 101: TFM I/O connector pin assignment Alvium G5/G5X User Guide V2.1.2...
  • Page 168: I/Os And Gpios

    Isolated input description External Internal 180R GPI3 OPT IN GND Figure 51: Input block diagram The input can be connected directly to the system for voltages up to 24 VDC. An external resistor is not necessary. Alvium G5/G5X User Guide V2.1.2...
  • Page 169: Isolated Output Description

    Figure 52: Minimum pulse width Test conditions The input signal was driven with 3.3 V and no external additional series resistor. Isolated output description Internal External OPT OUT PWR GPO2 Figure 53: Output block diagram Alvium G5/G5X User Guide V2.1.2...
  • Page 170 Figure 54: Output switching times Parameter and value  1 µs  26 µs  1 µs  21 µs  2 µs  47 µs )t can deviate by  5 µs( Table 105: Output parameters Alvium G5/G5X User Guide V2.1.2...
  • Page 171: Non-Isolated Gpios Description

    The camera has two non-isolated GPIOs that can be configured by software to act as inputs or outputs. Alvium G5/G5X GPIOs use the push-pull technology to switch the signal level between low and high. For low levels, the signal is "pulled" down towards ground level.
  • Page 172 12 mA Table 107: GPIOs as output, current and voltage levels Output voltage for U (high) = On state The voltage level in the On state depends on the load current. Higher currents yield lower voltage. Alvium G5/G5X User Guide V2.1.2...
  • Page 173: Status Leds

    Camera interfaces Status LEDs Alvium G5/G5X cameras have LEDs to signal in yellow, green, or red color. LED settings You can define LED settings with the feature: DeviceIndicatorLuminance • A value of 10 enables LED signaling at the highest luminance level.
  • Page 174: Triggering And Timings

    Triggering and timings This chapter includes: Trigger signal flow ............... 175 Trigger latency..............175 Triggering with rolling shutter cameras......176 Alvium G5/G5X User Guide V2.1.2...
  • Page 175: Trigger Signal Flow

    We recommend you to trigger on the rising edge for the fastest reaction time. Electronic rolling shutter )ERS( cameras in this document also have exposure delay, depending on camera settings, see Triggering with rolling shutter cameras on page 176. Electronic rolling shutter is commonly called rolling shutter. Alvium G5/G5X User Guide V2.1.2...
  • Page 176: Triggering With Rolling Shutter Cameras

    Triggering and timings Triggering with rolling shutter cameras Alvium G5-500, G5-831, G5-832, G5-1240, and G5/G5X-2050 Figure 57 shows how an external signal triggers exposure and readout for cameras with rolling shutter sensors. Like for global shutter sensors, readout has a constant duration, acquisition must be active to enable exposure, the end of exposure starts readout.
  • Page 177: Ignored Triggers

    Triggering and timings Ignored triggers Alvium G5-500, G5-831, G5-832, G5-1240, and G5/G5X-2050 Changing parameters while acquisition is active leads to ignored triggers until the parameters get active. Trigger features and UserSetDefault Trigger features and UserSetDefault on page 135. Alvium G5/G5X User Guide V2.1.2...
  • Page 178: Image Data Flow

    Image data flow This chapter includes: Image data flow diagram ............ 179 FPNC support ..............180 Alvium G5/G5X User Guide V2.1.2...
  • Page 179: Image Data Flow Diagram

    Image data flow Image data flow diagram Figure 58 shows image data processing for Alvium G5/G5X cameras in general. Sensor Sensor binning Sensor binning Region of interest Region of interest Region of interest Sensor frontend Sensor frontend Reverse Y Reverse Y...
  • Page 180: Fpnc Support

    Image data flow Feature descriptions and firmware downloads Alvium Features Reference: www.alliedvision.com/en/support/ technical-documentation/alvium-gige-documentation Firmware downloads: www.alliedvision.com/en/support/firmware-downloads. FPNC support Table 111 shows which Alvium G5 models support FPNC )Fixed pattern noise correction(: FPNC FPNC Alvium model Sensor Alvium model Sensor support...
  • Page 181: Firmware Update

    Firmware update This chapter describes how firmware is updated on Alvium G5/G5X cameras. Alvium G5/G5X User Guide V2.1.2...
  • Page 182: Please Note

    3. Connect your Alvium camera to the host. 4. Execute the installer of the firmware updater. The Vimba X Firmware Updater window opens, displaying your camera and the installed firmware version. 5. Continue with Updating the firmware on page 183. Alvium G5/G5X User Guide V2.1.2...
  • Page 183: Updating The Firmware

    Figure 60: The camera and installed firmware are displayed 2. Select the firmware for the update from the drop-down menu. Figure 61: The firmware version is selected 3. Click Update cameras. Figure 62: The update is being prepared Alvium G5/G5X User Guide V2.1.2...
  • Page 184 Figure 63: The command to update the firmware is confirmed The update progress is displayed. Figure 64: The update progress is displayed 5. Click Close to confirm the completion of the update. Figure 65: The update has been successfully completed Alvium G5/G5X User Guide V2.1.2...
  • Page 185: Error Handling

    Figure 66: The updated firmware version is displayed Error handling If firmware update fails, • The camera is not recognized by Vimba X Viewer. • You can repeat the firmware update. Should the firmware update not succeed, please contact support at www.alliedvision.com/en/about-us/contact-us/technical-support-repair-/-rma. Alvium G5/G5X User Guide V2.1.2...
  • Page 186: Performance And Troubleshooting

    Performance and troubleshooting This chapter includes: Tips and tricks to connect 5GBASE-T ........187 Optimizing performance............. 194 Reference system ..............201 Troubleshooting common issues ........203 Alvium G5/G5X User Guide V2.1.2...
  • Page 187: Tips And Tricks To Connect 5Gbase-T

    Mako or Prosilica GT cameras. This section is going to help you set up applications more easily. Dropped frames The data rates output by current Alvium G5/G5X cameras may create very high load on your system. Make sure that you are using the latest firmware and software for optimum performance and reliability.
  • Page 188: Nic Hardware Installation

    This can result in lost packets inside the NIC or the network stack. Although Intel NICs may work in the correct host setup, we do not recommend using them with Alvium G5/G5X cameras. This limitation may not apply to all Intel NIC families or may be resolved in future generations.
  • Page 189: Nic Driver Settings

    • Enable sufficient bandwidth for NICs on the PCIe link: minimum 1 × 8 GT/s or 2 × 5 GT/s or 4 × 2.5 GT/s is required for one Alvium G5/G5X camera. Under Windows, you can use the PowerShell command...
  • Page 190: Operation System Settings

    Vimba X TL settings Configuring the transport layer settings in Vimba X, can help to reduce dropped frames significantly. Look out for GenICam feature names starting with GVSP Because every system is specific, individual experiments must be done. Alvium G5/G5X User Guide V2.1.2...
  • Page 191 Switching and transferring data between the kernel space and the user space is a time consuming process. This limits the number of GVSP packets a system can handle per second. A 5GBASE-T link can easily exceed this limit. Alvium G5/G5X User Guide V2.1.2...
  • Page 192 We recommend allowing the maximum packet size possible. To determine the maximum packet size supported by your system, the Vimba X APIs include an automatic detection: Executing the command first GVSPAdjustPacketSize negotiates with the camera for the best possible packet size, then automatically sets GVSPPacketSize Alvium G5/G5X User Guide V2.1.2...
  • Page 193 GVSPMissingSize is used to cancel the reception of a single frame if the resend GVSPMissingSize limit GVSPMaxRequests is reached for too many packets. The frame is marked as incomplete and returned to the GenTL consumer. Alvium G5/G5X User Guide V2.1.2...
  • Page 194: Sharing Network Bandwidth

    We recommend using point-to-point links for best performance. If you must aggregate several cameras over a common link, add an offset to the calculated throughput. In fact, a shared 10G link can limit the performance of two Alvium G5/ G5X cameras connected.
  • Page 195: Parameter Changes

    Performance and troubleshooting Parameter changes Alvium G5-500, G5-831, G5-832, G5-1240, and G5/G5X-2050 If parameters are changed while these cameras are streaming, the following effects can occur. Stopped streaming When set to : If cameras are triggered by AcquisitionMode MultiFrame , the streaming stops when parameters are changed.
  • Page 196: Value Changes By Feature Interdependencies

    • The more features you adjust, the more current values deviate from previously set values. • The same effects that apply to ExposureTime , also apply to AutoExposure • To avoid readjustments, apply settings in the order shown in Figure Alvium G5/G5X User Guide V2.1.2...
  • Page 197 Alvium G5-831, G5-832, G5-1240, and G5/G5X-2050 Generally, long exposure times result in low frame rates because one is roughly the inverse of the other. For Alvium G5/G5X cameras with Sony IMX RS sensors: • The range of available frame rates depends on the exposure time.
  • Page 198: Dark Current Compensation

    Dark current compensation All sensors accumulate dark current in the pixels. Dark current increases the signal level and black level. Most sensors in Alvium G5/G5X cameras compensate for this. If cameras are operated at high temperatures or long exposure times, compensation reaches its limits.
  • Page 199: Shutter Types Affecting Image Readout

    Performance and troubleshooting Shutter types affecting image readout Most Alvium G5/G5X camera models are operated using global shutter )GS(: Property Line readout Moving image Global shutter )GS( Time Alvium G5-500, G5-831, G5-832 models use rolling shutter )RS(. Alvium G5-1240 and G5/G5X -2050 models offer global reset shutter )GRS( in addition:...
  • Page 200: Devicepowersavingmode

    Hardware and bandwidth For a smooth data transfer of Alvium G5/G5X cameras, the host computer must be equipped with a high-bandwidth 5GBASE-T compliant NIC. We recommend using direct point-to-point links from camera to NIC for best performance. See Recommended NICs on page 188.
  • Page 201: Reference System

    Performance and troubleshooting Vimba X settings During freerun, Alvium G5/G5X cameras do not automatically adapt the frame rate to the limits of your system, including the NIC. If the data rate is too high, it receives corrupted frames. The image transfer status in Vimba X Viewer is signaled as Running.
  • Page 202: Feature Values

    These values enable the host to request resent packets and sent command packets. This feature is disabled when GVSPDriverSelector is set to Filter Table 117: Feature values Description for camera and transport layer features See the Alvium Features Reference: www.alliedvision.com/en/support/technical- documentation/alvium-gige-documentation. Alvium G5/G5X User Guide V2.1.2...
  • Page 203: Troubleshooting Common Issues

    Ethernet cabling. NICs and NIC ports NICs or Ethernet adapters using Intel I219-LM chipset may not activate the link when an Alvium G5/G5X camera is connected directly. As a workaround, connect the camera to a different network adapter. Ethernet adapter settings...
  • Page 204: Camera Cannot Acquire Images

    • Increase the exposure time value, using ExposureTimeAbs • Ensure the lens is properly installed and the lens cap has been removed. Application support If you are still having problems, please contact support at www.alliedvision.com/en/about-us/contact-us/technical-support-repair-/-rma. Alvium G5/G5X User Guide V2.1.2...
  • Page 205: Avoiding Dropped Packets

    - In code, when application starts use capset)( to release all but these privileges: CAP_SYS_NICE, CAP_NET_ADMIN, CAP_NET_BROADCAST, CAP_NET_RAW. The application will start with all root privileges, but it will drop them immediately after startup. Alvium G5/G5X User Guide V2.1.2...
  • Page 206: Index

    .........41 GenICam ............49 readout modes..........53 GigE Vision ............49 reference system ........... 201 global reset shutter )GRS( ......199 ROI frame rates ..........52 global shutter )GS(......... 199 rolling shutter )RS( ......... 199 Alvium G5/G5X User Guide V2.1.2...
  • Page 207 ............135 shock and vibration ..........49 specifications ............48 standards applied ..........49 vignetting ............139 status LEDs............. 173 streaming is stopped ........195 white balance default ........127 technical drawings......... 128 Alvium G5/G5X User Guide V2.1.2...