UfiSpace S9600-102XC Hardware Installation Manual

Open aggregation router

Advertisement

Quick Links

S9600-102XC
Open Aggregation Router
Hardware Installation Guide
R1.2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S9600-102XC and is the answer not in the manual?

Questions and answers

Summary of Contents for UfiSpace S9600-102XC

  • Page 1 S9600-102XC Open Aggregation Router Hardware Installation Guide R1.2...
  • Page 2: Table Of Contents

    Connecting the 1PPS Interface ....................26 Connecting the 10MHz Interface ................... 27 Connecting the Transceiver ....................27 Installing an Antenna ......................28 13 Cautions and Regulatory Compliance Statements .............. 30 Cautions and Regulatory Compliances .................. 30 S9600-102XC Hardware Installation Guide | i...
  • Page 3: Overview

    5G mobile Ethernet network. Due to its versatility, the S9600-102XC can be positioned in different parts of the network to perform aggregation, such as in the backhaul to aggregate BBU pooling or even as a Broadband Network Gateway (BNG) within the central office.
  • Page 4: Preparation

    PC with terminal emulation software. Refer to the "Initial System Setup" section for details. • Baud rate: 115200 bps • Data bits: 8 • Parity: None • Stop bits: 1 • Flow control: None S9600-102XC Hardware Installation Guide | 2...
  • Page 5: Installation Environment Requirements

    1.19 inches (3cm). Therefore, to accommodate the fan and power supply handles, cable routing, a minimum space clearance of 6 inches (15.2cm) is needed at the back and front of the S9600-102XC. A total minimum reserve depth of 36 inches (91.44cm) is required.
  • Page 6: Preparation Check List

    S9600-102XC requires 2RU (3.45”/8.8cm) in height, 19” (48.3cm) in width, and need a minimum reserve depth of 36 inches (91.44cm) Thermal requirements S9600-102XC working temperature is 0 to 45°C (32°F to 113°F), airflow direction is front-to-back Installation tools required #2 Philips Screwdriver, 6-AWG yellow-and-green wire stripper, and...
  • Page 7: Package Contents

    72.05” (1830mm) 2 pcs 0.71lb (325g)/1 pcs (AC version only) SMB TO BNC 0.08lb (36g)/2 pcs 11.81” (300mm) 2 pcs Converter Cable 0.04lb (18g)/1 pcs USB 3.0 Cable 7.87” (200mm) 1 set 0.03lb (17.2g)/1 pcs S9600-102XC Hardware Installation Guide | 5...
  • Page 8: Component Physical Information

    AC power cord (AC version only) 0.71lb (325g) SMB TO BNC Converter Cable 0.04lb (18g) S9600-102XC (W x D x H) 17.16” x 24” x 3.45” (436 x 609.6 x 87.7mm) Dimension PSU (W x D x H) 1.99” x 12.64” x 1.57” (50.5 x 321 x 39.9mm) Fan (W x D x H) 3.2”...
  • Page 9: Identifying Your System

    4 Identifying Your System S9600-102XC Overview Figure 4. PSU Overview Power supply unit (PSU) with 1+1 Redundancy. Hot swappable, field replaceable unit (FRU). AC Version: Figure 5. S9600-102XC Hardware Installation Guide | 7...
  • Page 10: Fan Overview

    DC Version: Figure 6. Fan Overview 3+1 Redundant, hot swappable, field replaceable unit (FRU). Figure 7. S9600-102XC Hardware Installation Guide | 8...
  • Page 11: Port Overview

    Port Overview Port ID Form Factor Maximum Support Distance Support Speed 0 ~ 95 SFP28 Up to 24.85mi(40km) 1/10/25G 96 ~ 101 QSFP28 Up to 49.7mi(80km) 40/100G Figure 8. S9600-102XC Hardware Installation Guide | 9...
  • Page 12: Rack Mounting

    Make sure the locking screw of the inner rail is positioned at the front of the chassis. 2.2 After the attachment pins are secured to the inner rail, lock the inner rail to the chassis using two M4 screws (one on each chassis side). S9600-102XC Hardware Installation Guide | 10...
  • Page 13 4.4 Push the blue release tab on each rail to unlock the rails and slide the chassis all the way into the rack. 4.5 Lock the chassis into place by using the screw on the front of the inner rail. S9600-102XC Hardware Installation Guide | 11...
  • Page 14 Figure 12. S9600-102XC Hardware Installation Guide | 12...
  • Page 15: Installing Fan Modules

    5. An audible click will be heard when the fan module is installed correctly. The fan module will not go in all the way if it is installed in the wrong direction. Figure 15. S9600-102XC Hardware Installation Guide | 13...
  • Page 16: Installing Power Supply Units

    1. Locate the red release tab on the PSU. Then press and hold down the release tab to unlock the PSU. 2. While holding down the red release tab, grip the PSU's handle and firmly pull it out of the power bay. DC Version: AC Version: Figure 17. S9600-102XC Hardware Installation Guide | 14...
  • Page 17 5. An audible click will be heard when the PSU is installed correctly. The PSU will not go in all the way if it is in the wrong direction. DC Version: AC Version: Figure 17. S9600-102XC Hardware Installation Guide | 15...
  • Page 18: Grounding The Router

    3. Insert the exposed grounding wire all the way into the hole of the grounding lug (provided with package contents). 4. Using a crimping tool, firmly secure the grounding wire to the grounding lug. Figure 19. S9600-102XC Hardware Installation Guide | 16...
  • Page 19 Figure 20. 6. Using 2 M4 screws and 2 washers (provided with the package contents), firmly lock the grounding lug to the designated grounding location on the router. Figure 21. S9600-102XC Hardware Installation Guide | 17...
  • Page 20: Connecting Power

    Also, please ensure that both PSUs have been properly installed before powering up the equipment, as the S9600-102XC is designed to support 1 + 1 power redundancy. 2. Attach the DC power cables to the lugs.
  • Page 21 Locate the DC power screw-type terminal block located on the PSU. Remove the plastic cover that is protecting the terminal block by pushing from the top or bottom of the cover and flipping open the cover outwards. Secure the one-holed lugs (with the DC power cable S9600-102XC Hardware Installation Guide | 19...
  • Page 22: Ac Version

    If connected correctly, when turned on, the LED on the PSU will light up with a Green color designating normal operation. AC Version 1. Ensure there is enough power to supply the system. The maximum system power consumption is 751 watts. It is recommended to ensure that S9600-102XC Hardware Installation Guide | 20...
  • Page 23 Also, please ensure that both PSUs have been properly installed before powering up the equipment, as the S9600-102XC is designed to support 1 + 1 power redundancy. 2. Attach the power cable.
  • Page 24: Verifying System Operation

    Fan fail: one or more Fans need service No Power Solid Green PSU0 is working normal Blinking Amber PSU0 fail (PSU0 need service) No Power Solid Green PSU1 is working normal Blinking Amber PSU 1 fail (PSU1 need service) S9600-102XC Hardware Installation Guide | 22...
  • Page 25: Psu Fru Led

    Additional information about fan status can be obtained by the LEDs located on the fan itself. LED Condition Equipment Status No input power Green Fan FRU function normal Amber Fan FRU abnormal, service is required S9600-102XC Hardware Installation Guide | 23...
  • Page 26: Initial System Setup

    After the connection is established, a prompt for the username and password displays. Enter the username and password to access the CLI. The username and password should be provided by the Network Operating System (NOS) vendor. S9600-102XC Hardware Installation Guide | 24...
  • Page 27: Cable Connections

    1. Connect one end of a straight-through Ethernet cable to the GNSS unit 2. Connect the other end of the straight-through Ethernet cable to the port marked “TOD” located on the front panel of the router. Figure 31. S9600-102XC Hardware Installation Guide | 25...
  • Page 28: Connecting The Gnss Interface

    The maximum length of the 1PPS coaxial SMB/1PPS Ethernet cable should not be more than 3 meters. Connect an external 1PPS cable with an impedance of 50 ohms to the port labelled “1PPS”. Figure 33. S9600-102XC Hardware Installation Guide | 26...
  • Page 29: Connecting The 10Mhz Interface

    It is also recommended the cabling be done by a professional who is grounded, such as by wearing an ESD wrist strap. The following the steps below for connecting a transceiver. S9600-102XC Hardware Installation Guide | 27...
  • Page 30: Installing An Antenna

    Read the following guidelines before installing an active antenna: • When an active antenna is installed, the S9600-102XC can supply up to 5V DC/150mA on the GNSS port. • If any GNSS amplifier, DC-blocked or cascaded splitter is inserted, the GNSS detection function might be affected, resulting in GNSS satellite clock errors.
  • Page 31 Figure 36. S9600-102XC Hardware Installation Guide | 29...
  • Page 32: Cautions And Regulatory Compliance Statements

    Warning: This equipment must be grounded. Do not defeat the ground conductor or operate the equipment without correctly grounding the equipment. If there is any uncertainty about the integrity of the equipment's grounding, please contact the electrical inspection authority or a certified electrician. S9600-102XC Hardware Installation Guide | 30...
  • Page 33 This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions. S9600-102XC Hardware Installation Guide | 31...
  • Page 34 (Type 2, 4, or 4a ports as described in GR-1089) and require isolation from the exposed OSP cabling. The addition of Primary Protectors is not sufficient protection in order to connect these interfaces metallically to an OSP wiring system.” S9600-102XC Hardware Installation Guide | 32...
  • Page 35 www.ufispace.com...

Table of Contents