UfiSpace S9600-30DX Hardware Installation Manual

UfiSpace S9600-30DX Hardware Installation Manual

Open aggregation router

Advertisement

Quick Links

S9600-30DX
Open Aggregation Router
Hardware Installation Guide
R1.0

Advertisement

Table of Contents
loading

Summary of Contents for UfiSpace S9600-30DX

  • Page 1 S9600-30DX Open Aggregation Router Hardware Installation Guide R1.0...
  • Page 2: Table Of Contents

    Connecting the GNSS Interface ..................... 27 Connecting the 1PPS Interface ....................27 Connecting the 10MHz Interface ................... 28 Connecting the Transceiver ....................28 13 Cautions and Regulatory Compliance Statements .............. 29 Cautions and Regulatory Compliances .................. 29 S9600-30DX Hardware Installation Guide | i...
  • Page 3: Overview

    5G mobile Ethernet network. Due to its versatility, the S9600-30DX can be positioned in different parts of the network to perform aggregation, such as in the backhaul to aggregate BBU pooling or even as a Broadband Network Gateway (BNG) within the central office.
  • Page 4: Preparation

    PC with terminal emulation software. Refer to the "Initial System Setup" section for details. • Baud rate: 115200 bps • Data bits: 8 • Parity: None • Stop bits: 1 • Flow control: None S9600-30DX Hardware Installation Guide | 2...
  • Page 5: Installation Environment Requirements

    1.19 inches (3cm). Therefore, to accommodate the fan and power supply handles, a minimum space clearance of 6 inches (15.2cm) is needed at the back of the S9600-30DX. A total minimum reserve depth of 36 inches (91.4cm) is required.
  • Page 6: Preparation Check List

    AC version: 100 – 120V, 13Ax2 ampere maximum 200 – 240V, 10Ax2 ampere maximum Installation spacing requirement S9600-30DX is 2RU (3.45”/8.8cm) in height, 19” (48.3cm) in width, and need a minimum reserve depth of 36 inches (91.4cm) Thermal requirement S9600-30DX working temperature is 0 to 45°C (32°F to 113°F),...
  • Page 7: Package Contents

    (626.3 x 43.8 x 20.8mm) 2 pcs Rail (for 4 post) 3.39lbs(1.54kg)/1pcs (21”~35” rack depth) Screw Kit (for Rack 2 Sets 2 x Screw M4.0*L5.5 0.004lbs (1.9g)/1 set Mount Bracket) Power Cord 2 pcs 72.05”(1830mm) 1.54lbs(700g)/ 2pcs S9600-30DX Hardware Installation Guide | 5...
  • Page 8: Component Physical Information

    0.27lbs (123.9g) AC power cord (AC version only) 0.7lbs (318g) 17.16” x 30” x 3.45” S9600-30DX (W x D x H) (436 x 762 x 87.6mm) Dimension PSU (W x D x H) 1.99” x 12.64” x 1.58” (50.5 x 321 x 40.2mm) Fan (W x D x H) 3.15”...
  • Page 9: Identifying Your System

    4 Identifying Your System S9600-30DX Overview Figure 4. PSU Overview Power supply unit (PSU) with 1+1 Redundancy. Hot swappable, field replaceable unit (FRU). AC Version: Figure 5. S9600-30DX Hardware Installation Guide | 7...
  • Page 10: Fan Overview

    DC Version: Figure 6. Fan Overview 3+1 Redundant, hot swappable, field replaceable unit (FRU). Figure 7. S9600-30DX Hardware Installation Guide | 8...
  • Page 11: Port Overview

    Port ID Form Factor Maximum Support Distance Support Speed 0 ~ 15 QSFP28 Up to 6.2mi (10km) 40GE/100GE 16~23 QSFP-DD Up to 279.61mi (450km) 40GE/100GE 24~29 QSFP-DD Up to 279.61mi (450km) 100GE/400GE Figure 8. S9600-30DX Hardware Installation Guide | 9...
  • Page 12: Rack Mounting

    Make sure the locking screw of the inner rail is positioned at the front of the chassis. 2.2 After the attachment pins are secured to the inner rail, lock the inner rail to the chassis using two M4 screws (one on each chassis side). S9600-30DX Hardware Installation Guide | 10...
  • Page 13 4.4 Push the blue release tab on each rail to unlock the rails and slide the chassis all the way into the rack. 4.5 Lock the chassis into place by using the screw on the front of the inner rail. S9600-30DX Hardware Installation Guide | 11...
  • Page 14 Figure 12. S9600-30DX Hardware Installation Guide | 12...
  • Page 15: Installing Fan Modules

    5. An audible click will be heard when the fan module is installed correctly. The fan module will not go in all the way if it is installed in the wrong direction. Figure 15. S9600-30DX Hardware Installation Guide | 13...
  • Page 16: Installing Power Supply Units

    3. Align the new PSU with the power bay, ensuring the PSU’s power connector is in the correct position. 4. Carefully slide the new PSU into the power bay and gently push until it is flush with the case. S9600-30DX Hardware Installation Guide | 14...
  • Page 17 5. An audible click will be heard when the PSU is installed correctly. The PSU will not go in all the way if it is in the wrong direction. Figure 18. S9600-30DX Hardware Installation Guide | 15...
  • Page 18: Grounding The Router

    4. Using a crimping tool, firmly secure the grounding wire to the grounding lug. Figure 19. 5. Locate the designated location for securing the grounding lug, which is located on the rear of S9600-30DX Hardware Installation Guide | 16...
  • Page 19 Figure 20. 6. Using 2 M4 screws and 4 washers (provided with the package contents), firmly lock the grounding lug to the designated grounding location on the router. Figure 21. S9600-30DX Hardware Installation Guide | 17...
  • Page 20: Connecting Power

    Also, please ensure that both PSUs have been properly installed before powering up the equipment, as the S9600-30DX is designed to support 1 + 1 power redundancy. 2. Attach the DC power cables to the lugs.
  • Page 21 (Top picture). Secure the one-hole lugs (with the DC power cable attached) to the terminal block (Middle picture). Put plastic cover back on terminal block S9600-30DX Hardware Installation Guide | 19...
  • Page 22: Ac Version

    Also, please ensure that both PSUs have been properly installed before powering up the equipment, as the S9600-30DX is designed to support 1 + 1 power redundancy. S9600-30DX Hardware Installation Guide | 20...
  • Page 23 If connected correctly, when turned on, the LED on the PSU will light up with a solid Green color designating normal operation. If only a single 110VAC power source is available, the S9600-30DX can still be powered using both PSUs (1000 watts each for a total output of 2000 watts).
  • Page 24: Verifying System Operation

    Solid Amber One or more FAN module(s) need service Blinking Amber Reserved No Power Solid Green PSU 0 is working well Blinking Green Reserved Solid Amber PSU 0 fail (PSU0 need service) Blinking Amber Reserved S9600-30DX Hardware Installation Guide | 22...
  • Page 25: Psu Fru Led

    Additional information about fan status can be obtained by the LEDs located on the fan itself. LED Condition Equipment Status No input power to all power supplies Green Fan FRU function normal Amber Fan FRU abnormal, service is required S9600-30DX Hardware Installation Guide | 23...
  • Page 26: Initial System Setup

    USB cable provided in the packaging contents. Download the suitable driver for your operating system (OS) using the URL below: • https://www.silabs.com/products/development-tools/software/usb-to-uart-bridge- vcp-drivers • https://www.silabs.com/ and search for CP210X Figure 28. S9600-30DX Hardware Installation Guide | 24...
  • Page 27: Cable Connections

    Connecting the USB Extender Cable Connect the USB 3.0 A Type plug (male connector) into the USB port (female connector) located on the front panel of the router. This USB port is a maintenance port. Figure 29. S9600-30DX Hardware Installation Guide | 25...
  • Page 28: Connecting A Cable To The Tod Interface

    1. Connect one end of a straight-through Ethernet cable to the GNSS unit 2. Connect the other end of the straight-through Ethernet cable to the port marked “BITS” located on the front panel of the router. Figure 31. S9600-30DX Hardware Installation Guide | 26...
  • Page 29: Connecting The Gnss Interface

    Connect an external GNSS antenna with an impedance of 50 ohms to the port marked “GNSS ANT” located on the front panel of the router. Figure 32. Connecting the 1PPS Interface Connect an external 1PPS cable with an impedance of 50 ohms to the port labelled “ 1PPS”. Figure 33. S9600-30DX Hardware Installation Guide | 27...
  • Page 30: Connecting The 10Mhz Interface

    3. Place the bail (wire handle) in the unlocked position and align the transceiver with the port. 4. Slide the transceiver into the port and gently push until it is secured in place. An audible click can be heard when the transceiver is secured in the port. S9600-30DX Hardware Installation Guide | 28...
  • Page 31: Cautions And Regulatory Compliance Statements

    Avertissement: Ne pas utiliser d’instruments optiques pour voir la sortie du laser. L’utilisation de instruments optiques pour afficher la sortie laser augmente les risques oculaires. Utilisez uniquement UL/CSA, IEC/EN60825-1 /-2 reconnu modules enfichables. S9600-30DX Hardware Installation Guide | 29...
  • Page 32 This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions. S9600-30DX Hardware Installation Guide | 30...
  • Page 33 www.ufispace.com...

Table of Contents