EPH Controls RFRB V2 Installation And Operation Manual page 21

Rf room thermostat with on/off button
Table of Contents

Advertisement

Delay start can be reactivated by:
1.
Lower the target below the current temperature.
2.
Press
to set the temperature.
3.
Increase the target above the zone temperature within 6° .
4.
Press
to con rm.
The heating will be delayed as per the graph on page 18.
If the di erence between the actual temperature and the target is
1°C the thermostat will delay starting for circa 40 minutes.
If the di erence between the actual temperature and the target is
3°C the thermostat will delay starting for circa 24 minutes.
If the di erence is 6°C or more then the thermostat will be switched
on immediately.
The time delay will change if the temperature drops from the
original calculation.
EPH Controls Ltd.
19