FOR YOUR SAFETY – This product must be installed and serviced by a contractor who is licensed and
qualified on pool equipment in accordance with the latest applicable version of AS3633, along with any
other applicable local or council codes/standards. Before installing this product, read and follow all warning
notices and instructions that accompany this product. Failure to follow warning notices and instructions may
result in property damage, personal injury, or death. Improper installation and/or operation may void
the warranty.
Improper installation and/or operation can create unwanted electrical hazards which may cause serious
injury, property damage, or death.
ATTENTION INSTALLER – This manual contains important information about the installation,
operation and safe use of this product. This information should be given to the owner/operator
of this equipment.
Installation and Operation Manual
WARNING

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CTX Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Astralpool CTX Series

  • Page 1 Installation and Operation Manual Pumps Series: CTX, XP, XF, E WARNING FOR YOUR SAFETY – This product must be installed and serviced by a contractor who is licensed and qualified on pool equipment in accordance with the latest applicable version of AS3633, along with any other applicable local or council codes/standards.
  • Page 2 Serial No. : AUSTRALIA WARRANTY: For full warranty terms and conditions and to register your warranty, visit www.astralpool.com.au/warranty and complete your details. Or scan the QR code to go directly to the registration page. NEW ZEALAND WARRANTY: For full warranty terms and conditions and to register your warranty, visit www.astralpool.co.nz/warranty and complete your details.
  • Page 3: Table Of Contents

    AstralPool CTX, XP, XF and E Series Pumps | Installation and Operation Manual ® Table of Contents Section 1. Important Safety Instructions ..4 Section 5. Operation ........12 Section 2. General Information ......6 5.1 Starting Up the Pump ......... 12 5.2 Pump Lid Removal ........
  • Page 4: Section 1. Important Safety Instructions

    AstralPool CTX, XP, XF and E Series Pumps | Installation and Operation Manual ® Section 1. Important Safety Instructions READ AND FOLLOW ALL INSTRUCTIONS All electrical work must be performed by a licensed electrician and conform to all national, state, and local codes. When...
  • Page 5 CTX, XP, XF and E Series Pumps | Installation and Operation Manual ® WARNING AstralPool Pumps are powered by a high-voltage electric motor and must be installed by a licensed or certified electrician or a qualified swimming pool service technician. WARNING The pump is for fixed installations only and to be used in conjunction with swimming pool equipment.
  • Page 6: Section 2. General Information

    Section 2. General Information Performance Curves CTX-Series Pump This manual provides installation and operation instructions for the AstralPool CTX, XP, XF and E Series pumps. Read these installation and operation instructions completely before proceeding with the installation. CTX 500 CTX 400...
  • Page 7: Dimensions

    AstralPool CTX, XP, XF and E Series Pumps | Installation and Operation Manual ® Dimensions 341mm 247mm 609mm 5x Pipe Diameter 273mm 295mm 216mm Figure 1. CTX-Series Pump Figure 3. XF-Series Pump 359mm 323mm 249mm 245mm 704mm 273mm 5x Pipe Diameter...
  • Page 8: Section 3. Getting Started

    NOTE: When a pump is located below the pool surface, a leak can result in large scale water loss or flooding. AstralPool is not responsible for flood loss or damage. 1. Pumps must be installed in accordance with the regulations of the Australian wiring rules AS/NZS 3000- 2018.
  • Page 9 AstralPool CTX, XP, XF and E Series Pumps | Installation and Operation Manual ® 4.1.1 Plumbing Guidelines 3. Unions on both the suction and discharge ports simplify installation and service while minimizing leaks at Using the correct pipe size (pipe diameter) is important threaded adapters.
  • Page 10: Pump Installation

    ANSI /ASME A112.19.8, its AstralPool pumps are powered by a high voltage electric motor and ® ® successor standard, ANSI/APSP-16 or the AU/NZS must be installed by a licensed or certified electrician or a qualified swimming pool service technician.
  • Page 11: Water Connections

    AstralPool A check valve is not required between the filter and the pumps are rated to a maximum head of 25 meters heater.
  • Page 12: Electrical Connections

    Section 5. Operation Electrical Connections WARNING Starting Up the Pump AstralPool pumps are powered by a high voltage electric motor and WARNING must be installed by a licensed or certified electrician or a qualified swimming pool service technician. Never run the pump without water. Running the pump “dry” for...
  • Page 13: Pump Lid Removal

    (3) attempts at priming, turn off the pump and WARNING verify the valves and jets are open. For assistance, call AstralPool Technical Support at Trapped air in the system can cause the filter lid to be blown off, 1300 186 875.
  • Page 14: Section 6. Maintenance

    1. Turn off the power to the pump. If the pump is located NOTE AstralPool recommends having a qualified service technician below the water level, close the check valves on the or electrician properly disconnect the electrical wiring at the suction and discharge sides of the pump to prevent switch or junction box.
  • Page 15: Section 7. Troubleshooting

    When there is an error condition, a message is displayed on the screen. When the error situation is corrected, the error message ends automatically. If the pump continues to perform incorrectly, please contact AstralPool at 1 300 186 875. Issue...