  • Page 1 Disclaimer COLUMBIA english Our commitment: excellence S I G N A T U R E...
  • Page 2 S I G N A T U R E INDEX 1. 1. Product sheet and technical specifications 1.1. Technical specifications table 1.2. Packaging 1.3. General dimensions 2. Quality controls passed checklist 3. Certificates available on the product, the production process and the systems implemented within the company.
  • Page 3 S I G N A T U R E 1. Product sheet and technical specifications COLUMBIA PUMP Astralpool’s most silent pump, now with an ATB motor. • • High performance pump for residential quality components; AISI-36 swimming pools, with high hydraulic...
  • Page 4: Characteristics Table

    7 4 0 6 0 3778 3779 ,75 ,7 50 43,5 4 40 35 3 4 7 0 Performance charts MOTOR 230 V 230/400 V 0,75 3770 377 377 3773 3774 3775 3776 3777 3778 3779 Columbia 3 HP (32779, 32778) H-Q ; dBA-Q...
  • Page 5 S I G N A T U R E Columbia 2 HP (32777, 32776) H-Q ; dBA-Q Columbia 1,5 HP (32775, 3277 4) H-Q ; dBA-Q Columbia 1 HP (32773, 32772) H-Q ; dBA-Q...
  • Page 6 S I G N A T U R E Columbia 3/4 HP (32770, 32771) H-Q ; dBA-Q • The continuous line displays the pump’s hydraulic curve. • The discontinuous line displays the pump’s noise level. CODE DESCRIPTION MAX. NOISE LEVEL (dB)
  • Page 7: General Dimensions

    S I G N A T U R E 1.3. General dimensions Ø F Ø F CODE Ø F 3770 0,75 HP II 84,50 383,50 46,50 377 0,75 HP III 84,50 383,50 46,50  HP II 84,50 383,50 46,50 377 3773  HP III 84,50...
  • Page 8 S I G N A T U R E 2. Quality controls passed checklist Quality certificates: Materials receipt: Receip control: Motor, fastening clamp, casing, impeller, diffuser, nut, pre-filter cover, pre-filter basket, stand, mechanical joins. Production process FLYWHEEL CONTROL Components Motor Electric text 100% Fastening clamp...
  • Page 9 S I G N A T U R E METALAST. SAU. CERTIFIES THAT: The Columbia pumps manufactured by METALAST, SAU, have been designed in accordance with the following European Regulations and Directives: • Machines safety Directive 89/39/CEE, amended by Directive 9/368/CEE.
  • Page 10 S I G N A T U R E 3. Certificates available on the product, the production process and the systems implemented within the company...
  • Page 11: Guarantee Certificate

    1.8. This Guarantee Certificate does not limit or prejudge the rights corresponding to the con- sumers by virtue of national compulsory standards. INDIVIDUAL TERMS .. This Guarantee covers the following AstralPool products and product ranges: “Filtration Pumps”. .. In order for this guarantee to be effective the purchaser must strictly follow the manufactur- er’s instructions included in the documentation accompanying the Product, if said documenta-...
  • Page 12 S I G N A T U R E .3. When a schedule is given to replace, maintain or clean certain parts or components of the Product, the guarantee will only be valid if this schedule has been followed correctly. LIMITATIONS 3..
  • Page 13 S I G N A T U R E 5. Standard design and general characteristics The pump’s standard operation has been designed based on the NSF International Standard, for  bars of maximum working pressure.The pump is only designed to be used for swimming pools at a maximum temperature of 35ºC with the pH and disinfectant levels within the limits set by the related Regulations.
  • Page 14 S I G N A T U R E 6. Parts description of the pump ) I I ) I I " 4 ) I I ) I I ) I I ) I I ) I I ) I I ) I I ) I I ) I I...
  • Page 15 Any breach of the storage information may cause damage to the product. 7.2. STORAGE: Store the Columbia pump under cover with a level of humidity that is not very high. Do not store the cardboard packaging under high humidity conditions for a prolonged period of time as this may cause deformities to the lower layers of the pallets.
  • Page 16: General Safety Regulations

    S I G N A T U R E 7.5. GENERAL SAFETY REGULATIONS 7.5.1. GENERAL SAFETY INSTRUCTIONS These symbols indicate the possibility of danger where the corresponding instructions are not followed. DANGER. Risk of electrocution. Failure to abide by these instructions may lead to the risk of electrocution. DANGER Failure to abide by these instructions may lead to the risk of injury or damage.
  • Page 17: Installation And Assembly

    S I G N A T U R E 7.6. INSTALLATION AND ASSEMBLY 7.6.1. GENERAL • Our pumps may only be assembled and installed in pools or ponds that are compliant with HD 384.7.70. Should you have any doubts, please consult your specialist. •...
  • Page 18 S I G N A T U R E • With any type of pump, 0.03 A differential protection must be fitted for electricity leakage protection (indicated on the diagrams). • Adjust the value of the thermal relay appropriately depending on the pump current. For pumps with a single-phase motor: •...
  • Page 19 S I G N A T U R E • Respect the electrical installation and connection conditions. Failure to do so may lead to the pump manufacturer declining all responsibility and rendering the guarantee null and void. • The motors are subject to the EEC standards with IP-55 protection. •...
  • Page 20: Start-Up Instructions

    S I G N A T U R E . Disconnect the machine from the mains. . Block all start-up devices. 3. Check that there is no voltage in the circuits, even in the auxiliary circuits and ad- ditional services. 4.
  • Page 21: Maintenance And Disassembly

    S I G N A T U R E • Check that the motor rotates in the correct direction by means of the fan located at the back of the motor that can be seen through the view hole on the fan cover (Fig. 6). •...
  • Page 22 S I G N A T U R E COMPONENT DESCRIPTION ESTIMATED WORKING LIFE O rings and general seals  year Mechanical seal  year Bearings  year The estimated working life of the parts above has been established according to normal product use and installation conditions.
  • Page 23: Troubleshooting

    S I G N A T U R E 9. Troubleshooting 1. The pump is not primed 4. The pump will not start 2. The pump releases only a small flow of water 5. The motor is making a noise but will not start 3.
  • Page 24 S I G N A T U R E ANCHOR DETAIL Anchor detail Fig 1 CORRECT INCORRECT Gasket Gasket Raccord Raccord Raccord Raccord Fig 2 Priming Fig 3...
  • Page 25 S I G N A T U R E Pump Fig 4 Pre-filter cover unit Pre-filter cover Tower joint Pre-filer Section join to be decned Basket Fig 5 Fan cover CORRECT INCORRECT Fig 6...
  • Page 26 S I G N A T U R E SINGLE PHASE MOTORS Condensor THREE PHASE MOTORS THREE PHASE SINGLE PHASE...
  • Page 27 S I G N A T U R E 10. DO AND DO NOT DO NOT Verify the state of the packaging and Leave the box outdoors or in very damp compliance with the stacking instruc- places. Transport and tions. Drag the pump.