OWN E R 'S MAN UAL - BX a n d C T X PU M P S
IMPORTANT SAFETY INSTRUCTIONS - READ AND FOLLOW ALL INSTRUCTIONS

Table of Contents

SECTION 1 - SAFETY INSTRUCTIONS........................................................ .......................................................... 2
SECTION 2 - INSTALLATION.................................................................................................................................... 3
SECTION 3 - MAINTENANCE .................................................................................................................................. 5
SECTION 4 - RESTART INSTRUCTIONS ............................................................................................................... 8
SECTION 5 - TROUBLESHOOTING........................................................................................................................ 9
SECTION 6 - TECHNICAL DATA ............................................................................................................................ 10
This manual contains important information about the installation, operation and safe use of this product. This information should be
given to the owner/operator of this equipment.
WARNING
Before installing this product, read and follow all warning notices and instructions accompanying this pump. Failure to follow
safety warnings and instructions can result in severe injury, death, or property damage. Call (904) 378-0999 for additional free
copies of these instructions.
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION
This pool pump must be installed by a licensed or certified electrician or a qualified pool installer in accordance with the latest
edition of the National Electrical Code, NFPA 70 ("NEC") and/or all applicable local and state codes and ordinances. Installations
in Canada must be in accordance with the latest edition of CSA C22.1 - the Canadian Electric Code, part 1 ("CEC").
Improper installation could cause an electrical hazard which may result in death or serious injury to pool users, installers, or
others due to electrical shock, and/or property damage. Always disconnect power to the pool pump at the circuit breaker
before servicing the pump. Failure to do so could result in death or serious injury to pool users, installers or others. To reduce
the risk of injury, do not permit children to use this product unless they are closely supervised at all times.
CAUTION
This pump is for use with permanently installed pools and may also be used with hot tubs and spas if so marked. Do not use
with storable pools, do not install within an outer enclosure or beneath the skirt of a hot tub or spa unless so marked.
SAVE THESE INSTRUCTIONS
FLUIDRA USA
8525 Mallory Road, Jacksonville, FL 32220 USA
Phone: (940) 378-0999 • Fax: (904) 378-0408
sales@fluidra.us • customerservice@fluidra.us
www.fluidra.us
1

Advertisement

loading

Summary of Contents for Astralpool BX series

  • Page 1: Table Of Contents

    OWN E R ’S MAN UAL - BX a n d C T X PU M P S IMPORTANT SAFETY INSTRUCTIONS - READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Table of Contents SECTION 1 - SAFETY INSTRUCTIONS........................2 SECTION 2 - INSTALLATION............................
  • Page 2: Section 1. Safety Instructions

    SECTION 1. SAFETY INSTRUCTIONS GENERAL When you receive the pump, check the carton for damage. Open the carton and check the pump for concealed damage, such as cracks, dents, or a bent base. If you find damage, contact the shipper or the distributor where the pump was purchased.
  • Page 3: Section 2. Installation

    SECTION 2. INSTALLATION Proper ventilation is required for the pump to operate normally. Provide access for future service by leaving a clear area around the pump. Allow plenty of space above the pump to remove the lid and basket for cleaning. Replacement of an Existing Pump: BX and CTX pumps can easily replace several other pumps including, Pentair®...
  • Page 4 (Figure 3b) Pump with base positioned to match Sta-Rite® (tm) type pumps (Figure 3c) Pump with base positioned to match WhisperFlo® type pumps...
  • Page 5: Section 3. Maintenance

    SECTION 3. MAINTENANCE WARNING DO NOT open the strainer pot if pump fails to prime, or if pump has been operating without water in the strainer pot. Pumps operated in these circumstances may experience a buildup of vapor pressure and may contain scalding hot water.
  • Page 6 WINTERIZING 1. If the air temperature drops below 35° F., the water in the pump can freeze and cause damage. Freeze damage is not warrantable. 2. To prevent freeze damage follow the procedures listed below: a. Shut off electrical power for the pump at the house circuit breaker. b.
  • Page 7 PUMP DISASSEMBLY 1. All moving parts are located in the rear sub-assembly of this pump. Tools required: a. 3/16 inch Allen head wrench. b. 1/2 inch open end wrench. c. 1/2 inch open end wrench or socket. d. Flat blade screwdriver or ¼ inch nut driver to remove motor cap. e.
  • Page 8: Section 4. Restart Instructions

    THE SHAFT SEAL (MECHANICAL SEAL) 1. The Shaft Seal consists primarily of two parts, a rotating member and a ceramic seal. See Figure 4. 2. The pump requires little or no service other than reasonable care, however, a Shaft Seal may occasionally become damaged and must be replaced.
  • Page 9: Section 5. Troubleshooting

    SECTION 5. TROUBLESHOOTING FAILURE TO PUMP Pump will not prime - too much air. Remedy: 1. Check suction piping and valve glands on any suction gate valves 2. Secure lid on pump strainer pot and make sure lid gasket is in place 3.
  • Page 10: Section 6. Technical Data

    SECTION 6. TECHNICAL DATA BX PUMP HYDRAULIC PERFORMANCE CURVES...
  • Page 11 CTX PUMP HYDRAULIC PERFORMANCE CURVES...
  • Page 12 EXPLODED VIEW...
  • Page 13 REPLACEMENT PARTS Code Part Number Description Quantity 53977-78736 BX Volute 53976-78735 CTX Volute 53977-78106 BX Pump Lid O-ring 53976-70006 CTX Pump Lid O-ring 53977-40086 BX Pump Clear Lid 53976-40087 CTX Pump Clear Lid 53977-40068 BX Pump Lid Collar 53976-40088 CTX Pump Lid Collar 53977-950925 BX 2”...
  • Page 14 WARRANTY AstralPool manufactures its products with the highest standards of workmanship, using the best materials available through state of the art processes. AstralPool warrants its products as follows: LIMITED WARRANTY: ASTRALPOOL WARRANTS ITS PRODUCTS TO BE FREE FROM DEFECTS IN MATERIAL AND/OR WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR (PARTS ONLY) FROM THE ORIGINAL DATE OF PURCHASE OR INSTALLATION.
  • Page 15 PROCEDURE FOR OBTAINING RETURN GOODS AUTHORIZATION In order to obtain the benefits of this warranty, the consumer who made the original retail purchase must contact the AstralPool Technical Service Department as soon as possible after discovery of the defect, but in no event later than the expiration date of the warranty period provided in this warranty.