Indoor Unit Electrical Panel Overview Unit Dimensions and Clearances ��������������������������������������������������������������������������������������������������� 6 Indoor Unit - EVA10AS Indoor Unit - EVA13AS / EVA15AS / EVA17AS / EVA20AS / EVA23AS Two-Piece Fan Coil Indoor Unit - Upright Fan Coil with Vertical Discharge Minimum Service Areas and Airflow Clearances Installation Instructions ��������������������������������������������������������������������������������������������������������������...
Check your air conditioning unit and all items against the invoice upon receiving your shipment. Inspect the unit, components and accessories for any sign of damage. If there is any damage to the unit, contact ActronAir Customer Care Department immediately on: 1300 522 722 to obtain a Goods Return Number.
PRELIMINARY DATA ONLY THIS LABEL TO BE REMOVED ON SIGN-OFF Aires Indoor Units Installation and Commissioning Guide Safety Instructions • Only licensed HVAC technicians* should install and service air conditioning equipment. Improper service or alteration by an unqualified technician could result in significant and major damage to the product or property which may render your warranty null and void.
PRELIMINARY DATA ONLY THIS LABEL TO BE REMOVED ON SIGN-OFF Aires Indoor Units Installation and Commissioning Guide Components Overview Indoor Unit Components Overview EC MOTOR COIL Single Fan for EVA10AS ELECTRICAL BOX COVER CONTROL PANEL Indoor Unit Electrical Panel Overview EMC FILTER TRANSFORMER (for EVA20/23AS models)
1000 mm between the units or between the unit and the outside perimeter is available. 3. Minimum service access areas and spaces for airflow clearances are responsibilities of the installer, ActronAir will not be held liable for any extra charges incurred due to lack of access and space for airflow.
THIS LABEL TO BE REMOVED ON SIGN-OFF Aires Indoor Units Installation and Commissioning Guide EVA MODELS 25032024.TCW EVA Dim Indoor Unit - EVA13AS / EVA15AS / EVA17AS / EVA20AS / EVA23AS W-RD NOTES: GAS PIPE INDOOR COIL Drawing is subject to change without notice.
Page 8
1000 mm between the units or between the unit and the outside perimeter is available. 3. Minimum service access areas and spaces for airflow clearances are responsibilities of the installer, ActronAir will not be held liable for any extra charges incurred due to lack of access and space for airflow.
1000 mm between the units or between the unit and the outside perimeter is available. 3. Minimum service access areas and spaces for airflow clearances are responsibilities of the installer, ActronAir will not be held liable for any extra charges incurred due to lack of access and space for airflow.
Page 10
1000 mm between the units or between the unit and the outside perimeter is available. 3. Minimum service access areas and spaces for airflow clearances are responsibilities of the installer, ActronAir will not be held liable for any extra charges incurred due to lack of access and space for airflow.
PROJECTION mounting hole details. 2. Minimum service access areas and spaces for airflow clearances are responsibilities of the installer, ActronAir will not be held liable for any extra charges incurred due to lack of access and space for airflow. 3. For installation with release height less than or equal to 0.6m, minimum area will be computed based on release height of 0.6m 4.
PRELIMINARY DATA ONLY THIS LABEL TO BE REMOVED ON SIGN-OFF Aires Indoor Units Installation and Commissioning Guide Minimum Service Areas and Airflow Clearances Indoor Unit - EVA13AS / EVA15AS / EVA17AS / EVA20AS / EVA23AS DUCT WORK INDOOR COIL LEFT *RIGHT...
Page 13
1000 mm between the units or between the unit and the outside perimeter is available. 3. Minimum service access areas and spaces for airflow clearances are responsibilities of the installer, ActronAir will not be held liable for any extra charges incurred due to lack of access and space for airflow.
Compliance and consultation with the authorities having jurisdiction with the installation of this equipment is the responsibility of the installer. ActronAir will not be held liable for any damages or costs as a result of the installer’s failure to comply. Please refer to the matching outdoor unit Installation and Commissioning Guide for further information and details.
Page 15
NOTES This indoor unit is designed to match only with an ActronAir Series outdoor unit as specified in the Technical Selection Catalogue. The unit is supplied with factory charged dry air. Be aware of the pressurised air charge when purging. Remove the caps from the connection points and purge the system only when the field pipe connections are ready to be completed.
NOTE Supply and Return Air Plenums must be as per ActronAir Plenums or equal to, or lower static pressure. Installation and Commissioning Guide - Aires Split Ducted Indoor Units Doc. No. 0525-134 Ver. 4 24xxxx...
PRELIMINARY DATA ONLY THIS LABEL TO BE REMOVED ON SIGN-OFF Aires Indoor Units Installation and Commissioning Guide Unit Lifting Procedures WARNING WH&S regulations must be observed and will take precedence during lifting process. Do not use pipes or tube coming out from the unit to lift the unit. Crane Lifting Method DANGER Make sure rigging equipment, accessories and plant are sufficiently and safely capable to lift the unit in order to prevent...
PRELIMINARY DATA ONLY THIS LABEL TO BE REMOVED ON SIGN-OFF Aires Indoor Units Installation and Commissioning Guide Procedure: 1. Slip nylon slings through the pallet as shown in Figure 1. 2. Use Bow or Dee shackle to connect the slings. 3.
PRELIMINARY DATA ONLY THIS LABEL TO BE REMOVED ON SIGN-OFF Aires Indoor Units Installation and Commissioning Guide Safety Drain Tray NOTES • Do not use pipes or tube coming out from the unit to lift the unit. • Support drain line for long pipe run. •...
(positions that range from 9 o’clock to 3 o’clock), as shown below: It is also recommended that only ActronAir 24V zones be connected to this system using RJ45 cable connections.RJ12 connections are not compatible on these systems. Warranty may be void if third party zones cause damage to the system.
PRELIMINARY DATA ONLY THIS LABEL TO BE REMOVED ON SIGN-OFF Aires Indoor Units Installation and Commissioning Guide Electrical Installation All electrical work must be carried out by a qualified technician. Make sure all wiring is in accordance with local wiring rules.
PRELIMINARY DATA ONLY THIS LABEL TO BE REMOVED ON SIGN-OFF Aires Indoor Units Installation and Commissioning Guide Wiring Diagram EVA10AS Base Variation Code: Variation: STANDARD Model No.: Description: WIRING DIAGRAM INDOOR BOARD + 8 ZONES WITH 3 WALL CONTROLLERS Drawing No: Sheet: Revision: Drawn:...
Page 25
PRELIMINARY DATA ONLY THIS LABEL TO BE REMOVED ON SIGN-OFF Aires Indoor Units Installation and Commissioning Guide EVA/EFA13AS Base Variation Code: Variation: STANDARD Model No.: Description: WIRING DIAGRAM INDOOR BOARD + 8 ZONES WITH 3 WALL CONTROLLERS Drawing No: Sheet: Revision: Drawn: 13/05/2024...
Page 26
PRELIMINARY DATA ONLY THIS LABEL TO BE REMOVED ON SIGN-OFF Aires Indoor Units Installation and Commissioning Guide EVA/EFA15AS Base Variation Code: Variation: STANDARD Model No.: Description: WIRING DIAGRAM INDOOR BOARD + 8 ZONES WITH 3 WALL CONTROLLERS Drawing No: Sheet: Revision: Drawn: 13/05/2024...
Page 27
PRELIMINARY DATA ONLY THIS LABEL TO BE REMOVED ON SIGN-OFF Aires Indoor Units Installation and Commissioning Guide EVA/EFA17AS Base Variation Code: Variation: STANDARD Model No.: Description: WIRING DIAGRAM INDOOR BOARD + 8 ZONES WITH 3 WALL CONTROLLERS Drawing No: Sheet: Revision: Drawn: 13/05/2024...
Page 28
PRELIMINARY DATA ONLY THIS LABEL TO BE REMOVED ON SIGN-OFF Aires Indoor Units Installation and Commissioning Guide Base EVA/EFA20AS Variation Code: Variation: STANDARD Model No.: Description: WIRING DIAGRAM INDOOR BOARD + 8 ZONES WITH 3 WALL CONTROLLERS Drawing No: Sheet: Revision: Drawn: 01/05/2024...
Page 29
PRELIMINARY DATA ONLY THIS LABEL TO BE REMOVED ON SIGN-OFF Aires Indoor Units Installation and Commissioning Guide Base EVA/EFA23AS Variation Code: Variation: STANDARD Model No.: Description: WIRING DIAGRAM INDOOR BOARD + 8 ZONES WITH 3 WALL CONTROLLERS Drawing No: Sheet: Revision: Drawn: 13/05/2024...
PRELIMINARY DATA ONLY THIS LABEL TO BE REMOVED ON SIGN-OFF Aires Indoor Units Installation and Commissioning Guide Electrical Connection NOTES • To minimise noise interference, Data and Power cable clearance should be maintained as much as possible. • All drawings are for illustration purposes only. Actual unit may vary depending on the model. •...
Aires Indoor Units Installation and Commissioning Guide Data Cable Shielding Instructions 2 Core Twisted (ActronAir Part Number: AEDC2) NOTES • Maintain the twist of the core wires up to the Green Terminal Plug. • Maximum strip length of outer insulation to the Green Terminal Plug is 50mm.
PRELIMINARY DATA ONLY THIS LABEL TO BE REMOVED ON SIGN-OFF Aires Indoor Units Installation and Commissioning Guide Wall Controller Options Wall Controller Options A maximum of three (3) wall controllers in the below combinations is allowed per unit. See below table. Wall Controllers Options 1st Option...
PRELIMINARY DATA ONLY THIS LABEL TO BE REMOVED ON SIGN-OFF Aires Indoor Units Installation and Commissioning Guide Wiring Configuration : Recommended NOTES • Diagram shown below is a general representation only. Refer to individual unit wiring diagram for complete wiring connection details.
PRELIMINARY DATA ONLY THIS LABEL TO BE REMOVED ON SIGN-OFF Aires Indoor Units Installation and Commissioning Guide Wiring Configuration : Alternate LR7-1 WALL INDOOR UNIT LR7-1 WALL CONTROLLER LR7-1 WALL CONTROLLER CONTROLLLER (OPTIONAL) (OPTIONAL) (OPTIONAL) Installation of the Outdoor Unit securely.
* All Zone Device Power Cable : Cat5E Spec Cables with RJ45 Connectors and Cable Boots - Green Colour • ** Total Cumulative length of all the aggregate cable must not exceed 250 meters. Consult ActronAir for longer cable length requirement.
1 to 4 (Optional 4 Zones Piggy-Back Configuration), if 1 to 3 is 75m, then 3 to 4 must be 25m to make a total of 100m. *** Recommended maximum cable length, providing total of preceding cable connections are only 5m. ^ Total Cumulative length of all the aggregate cable must not exceed 500 meters. Consult ActronAir for longer cable length requirement.
PRELIMINARY DATA ONLY THIS LABEL TO BE REMOVED ON SIGN-OFF Aires Indoor Units Installation and Commissioning Guide Wiring Connections LR7-1 and LC7-2 Wall Control Wiring Connections INDOOR WALL CONTROL WIRING CONTROL BOARD POWER: - BROWN / ORANGE 485 A: - BLUE WALL CONTROLLER +12V A 485 B:...
PRELIMINARY DATA ONLY THIS LABEL TO BE REMOVED ON SIGN-OFF Aires Indoor Units Installation and Commissioning Guide LM-RS-2 Optional Sensor Wiring Connections INDOOR CONTROL REMOTE SENSOR WIRING BOARD PAIR 1: - BLUE / BLUE-WHITE PAIR 2: - ORANGE / ORANGE-WHITE TEMP PAIR 3: - GREEN / GREEN-WHITE SENSORS...
PRELIMINARY DATA ONLY THIS LABEL TO BE REMOVED ON SIGN-OFF Aires Indoor Units Installation and Commissioning Guide Zone Commissioning When the unit is powered on, zone detection will automatically start. This will take 2 minutes to complete. A zone detection can also be manually triggered on the LR7-1/LC7-2 controller by pressing the ON/OFF button and Zone 1 button for 3 seconds.
PRELIMINARY DATA ONLY THIS LABEL TO BE REMOVED ON SIGN-OFF Aires Indoor Units Installation and Commissioning Guide Maintenance Frequency Checklist Regular servicing of equipment by a qualified technician is recommended every 12 months for residential applications and every quarter for commercial applications. Regular servicing of your unit helps in maintaining its optimum performance and reliability.
PRELIMINARY DATA ONLY THIS LABEL TO BE REMOVED ON SIGN-OFF Aires Indoor Units Installation and Commissioning Guide Version History DOCUMENT VERSION BOM VERSION UPDATE HISTORY Ver 1 -010 Released Ver 2 -010 R-32 restriction clause update Ver 3 -010 Updated image and added dimension table Ver 4 -010 Added 23kW and 23kW...
Need help?
Do you have a question about the EVA20AS and is the answer not in the manual?
Questions and answers