Brinkmann Immersions pumps of the series SFL550…1150 Contents 9 Trouble shooter’s guide ........7 Indication to the manual ........2 Description of product ........2 10 Spare part ............8 Safety instructions ..........4 11 Repair ............... 9 Transport and storage ........4 12 Disposal ............
Page 3
Technical data Max. del. Max. del. Height Depth of Weight Power pressure bar / volume immersion 50 / 60 Hz Type spec. weight 1 l/min H mm h mm SFL550 / 150 0.92 / 1.06 / 230 / 300 / 380 / 470 / 580 SFL650...
3 Safety instructions Safety instructions relevant for operation When operating the pump, the safety instructions • If hot or cold machine components involve contained in this manual, the relevant national hazards, they must be guarded against acci- accident prevention regulations and any other dental contact.
5 Installation and Connection Electric wiring Mechanical installation During any assembly or disassembly process the pumps must be secured against tipping trough ropes for example at all times. All service work must be carried out by quali- Pumps must be mounted securely. Piping, tank and fied service personnel.
Wiring diagram e.g. Star connection 3 x 400 V, 50 Hz resp. 380-415 V, 50 Hz Delta connection 3 x 230 V, 50 Hz resp. 220-240 V, 50 Hz max. liquid level There may be no foreign objects such as dirt, particles or humidity inside the terminal board.
9 Trouble shooter’s guide Fault Cause Remedy Motor does not start, no motor At least two of the power supply Check fuses, terminals and supply noise leads have failed leads . Overload has tripped Inspect overload Motor does not start, humming noise One of the supply leads has failed See above Impeller faulty...
10 Spare part 10.1 Spare part list for the immersion pumps of the series SFL550…1150 Item Description Stator with terminal board Motor flange End shield Terminal box Fan cover Ball bearing 2.2…2.6 kW DIN 628 Ball bearing DIN 625 10 Ball bearing DIN 625 11 Gasket 13 Retaining ring 2.2…2.6 kW...
10.2 Indications to the spare part order 11.2 Assembling the insert shaft and motor shaft Spare parts are available from the supplier. Standard commercially available parts are to be ATTENTION purchased in accordance with the model type. The ordering of spare parts should contain the Clean the contact surfaces of the insert shaft (2) following details: (inside) and the motor shaft (3).
Manufacturer Brinkmann Pumpen, K. H. Brinkmann GmbH & Co. KG Friedrichstraße 2 D-58791 Werdohl Germany This declaration of conformity is issued under the sole responsibility of Brinkmann Pumps and belongs to the following product. Product name Immersion pumps Type SFL550…1150 The named product described above complies with the following statutory requirements of United Kingdom: UK SI 2008 No.
Page 11
13.2 EC declaration of conformity DEUTSCH / ENGLISH /FRANÇAIS / ESPAÑOL EG-Konformitätserklärung EC declaration of conformity / Déclaration de conformité CE / Declaración de conformidad CE Hersteller / Manufacturer / Constructeur / Fabricante Brinkmann Pumpen, K. H. Brinkmann GmbH & Co. KG Friedrichstraße 2, D-58791 Werdohl Produktbezeichnung / Product name / Désignation du produit / Designación del producto Tauchpumpen / Immersion pumps / Pompes plongeantes / Bombas de inmersión...
Need help?