Omron VARISPEED J7 System Configuration Manual page 3

Table of Contents

Advertisement

Commom specifications
Model
CIMR-J7AZ#
Control method
Output frequency range
Frequency tolerance
Resolution of frequency set value
Resolution of output frequency
Overload capability
Frequency set value
Accel/decel time
Braking torque
V/f characteristics
Digital inputs
Digital outputs
Standard functions
Display
Motor overload protection
Instantaneous overcurrent
Overload
Overvoltage
Undervoltage
Momentary power loss
Cooling fin overheat
Stall prevention level
Cooling fan fault
Ground fault
Power charge indication
Degree of protection
Cooling
Ambient temperature
Ambient humidity
Storage temperature
Installation
Installation height
Vibration
1.
Shows deceleration torque for uncoupled motor decelerating from 60 Hz with the shortest possible deceleration time.
Varispeed J7
Digital reference: 0.01 Hz (less than 100 Hz), 0.1 Hz (100 Hz or more)
0 to 10 VDC (20 k ), 4 to 20 mA (250 ), 0 to 20 mA (250 ), frequency setting volume (selectable)
0.1 to 999 sex. (accel/decel time are independently programmed)
Short-term average deceleration torque
Four of the following input signals are selectable: forward/reverse run (3-wire sequence), fault reset, external fault (NO/NC
contact input), multi-step speed operation, jog command, accel/decel time select, external baseblock (NO/NC contact input),
speed search command, UP/DOWN command, accel/decel hold command, LOCAL/REMOTE selection, communication/
control circuit terminal selection, emergency stop fault, emergency stop alarm, self test
Following output signals are selectable (NO/NC contact output): Fault, running, zero speed, speed agreed,
frequency detection (output frequency
operation mode, inverter run ready, during fault retry, during undervoltage detection, reverse running, during speed search,
data output through communication
Full-range automatic torque boost, slip compensation, 9-step speed operation (max.), restart after momentary power loss,
DC injection braking current at stop/start (50% of inverter rated current, 0.5 sec, or less), frequency reference bias/gain, fault
retry, speed search, frequency upper/lower limit setting, overtorque detection, frequency jump, accel/decel time switch, accel/
decel prohibited, S-curve accel/decel, frequency reference with built-in volume, constants copy (option) MEMOBUS commu-
nications (option)
Status indicator LED: RUN and ALARM provided as standard LED's
Digital operator: available to monitor frequency reference, output frequency, output current
Motor coasts to a stop at approx. 250% of inverter rated current
Motor coasts to a stop after 1 minute at 150% of inverter rated output current
Motor coasts to a stop if DC bus voltage exceed 410 V (double for 400 V class)
Stops when DC bus voltage is approx. 200 V or less (double for 400 V class)
Following items are selectable: Nnot provided (stop if power loss is 15ms or longer),
continuous operation if power loss is approx. 0.5 s or shorter, continuous operation
Individual level stall prevention can be set during acceleration or constant running,
provided/not provided setting available during deceleration.
Protected by electronic circuit (operation level is approx. 250% of rated output current)
ON until the DC bus voltage becomes 50 V or less, RUN lamp stays ON or digital operator LED stays ON.
Self cooling for 200 V 0,1..0,75 kW (single-phase) 0,1..0,4 kW (Three-phase) and for 400 V 0,2..0,75l kW
Cooling fan for 200 V (single-phase), 0.75 kW..4.0 kW (3-phase) and for 400 V 1,5..4.0 kW
-20 ºC..+60 ºC (short-term temperature during trasnportation)
Specifications
Sine wave PWM (V/f control)
0.1 to 400 Hz
Digital reference: ±0.01% (–10 to +50 °C),
Analog reference: ±0.5% (25±10 °C)
Analog reference: 1/1000 of max. output frequency
0.01 Hz
150% rated output current for one minute
1
: 0.1, 0.2 kW (0.13 HP, 0,25 HP): 150% or more;
0.4/0.75 kW (0,5 HP, 1HP): 100% or more;
1.5 kW (2 HP): 50% or more;
2.2 kW (3 HP) or more: 20% or more
Continuous regenerative torque: Approx 20%
Possible to program any V/f pattern
or
set value), during overtorque detection, minor error, during baseblock,
Electronic thermal overload relay
(approx. 160 V or less for single-phase series)
Protected by thermister
Detected by electronic circuit (fan lock detection)
(Charge LED is provided for 400 V)
IP20
-10 ºC to 50 ºC (non-freezing)
90% RH or less (non-condensing)
Indoor (no corrosive gas, dust, etc.)
Max. 1000 m
2
10 to 20 Hz, 9.8 m/s
max; 20 to 50 Hz, 2m/s
2
max
353