Analog Input Calculate Function - Omron MX2 User Manual

200 v class three-phase input 0.1 to 15 kw 200 v class single-phase input 0.1 to 2.2 kw 400 v class three-phase input 0.4 to 15 kw
Hide thumbs Also See for MX2:
Table of Contents

Advertisement

"A" Group: Standard Functions
Func.
Code
A104
A105
*1
Up to 1000Hz for High frequency mode (d060 set to "2")
*2
Up to 1000Hz for High frequency mode (d060 set to "2")
A input select
B input select
Func.
Code
A141
"A" Function
Name
[OI] input active range end cur-
rent
[OI] input start frequency
select
Refer to parameter A011 to A015 for analog voltage input.
Analog Input Calculate Function - The inverter can mathematically combine
two input sources into one value. The Calculate function can either add, sub-
tract, or multiply the two selected sources. This provides the flexibility needed
by various applications. You can use the result for the output frequency setting
(use A001=10) or for the PID Process Variable (PV) input (use A075=03).
Digital operator
Remote operator POT
[O] input
[OI] input
Network variable
Digital operator
Remote operator POT
[O] input
[OI] input
Network variable
"A" Function
Name
A input select for calculate
function
Description
The ending point (offset) for the
current input range, range is 0. to
100.%
Two options; select codes:
00... Use offset (A101 value)
01... Use 0 Hz
A141
A
B
A142
Description
Seven options:
00... Operator
01... VR
02... Terminal [O] input
03... Terminal [OI] input
04... RS485
05... Option
07... Pulse train input
Section 3-5
Run
Defaults
Mode
EU
Units
Edit
100.
%
00
A143
"CAL"
• A + B
(result)
• A - B
• A * B
Run
Defaults
Mode
EU
Units
Edit
02
97