Omron K3HB-C User Manual page 76

Digital indicators
Hide thumbs Also See for K3HB-C:
Table of Contents

Advertisement

func
0
(FUNC)
func
0
3 s min.
f1
Displays "L 0."
func
0
f1
func
0
f2
in-ta
0
00
Example:
This example shows the prescale values and the prescale set
values for measuring the passing time using a rotary encoder that
outputs 100 pulses per rotation.
Circumferential length per rotation ( d)= 0.125 mm
Length of processing stage = 5 m
Prescale value ( ) = 5/(0.125/100) = 4,000 = 4.0000
Prescale value of Input A, X (mantissa): ps. ax = 4. 0000
Prescale value of Input A, Y (exponent): ps. ay = 10 03
Use the following parameter to set the function.
Parameter
Function
func
Parameter Setting Procedure
A Press the L [LEVEL] Key for at least 3 s in RUN level to move to
the initial setting level.
0" is displayed on the level/bank display to indicate the initial
• "
L
setting level.
B Press the S [SHIFT] Key to make the SV display flash.
• The setting can be changed when the SV display starts to
flash.
C Use the U [UP] Key to change the set value.
D Press the M [MODE] Key to switch the display to the next PV.
• The set value is registered.
5.1 Setting the Function for the K3HB-R
Set
Meaning of set value
value
f1
Rpm/circumferential speed
f2
Absolute ratio
f3
Error ratio
f4
Rotational difference
f5
Flow rate ratio
f6
Passing time
3
10
5-15