Omron K3HB Datasheet page 31

Digital indicators k3hb series
Hide thumbs Also See for K3HB:
Table of Contents

Advertisement

20.Do not pull the DeviceNet communications cables with excessive
force or bend them past their natural bending radius.
21.Do not connect or remove connectors while the DeviceNet power
is being supplied. Doing so will cause product failure or
malfunction.
22.Use cables with heat resistance of 70 C min.
■ Noise Countermeasures
1. Do not install the product near devices generating strong high-
frequency waves or surges, such as high-frequency welding and
sewing machines.
2. Mount a surge suppressor or noise filter to peripheral devices
generating noise, in particular, motors, transformers, solenoids,
and magnet coils.
Line filter
Digital
Indicator
3. In order to prevent inductive noise, wire the lines connected to the
terminal block separately from power lines carrying high voltages
or currents. Do not wire in parallel with or in the same cable as
power lines. Other measures for reducing noise include running
lines along separate ducts and using shield lines.
Example of Countermeasures for Inductive Noise on
Input Lines
2 conductors
with shield
4. If a noise filter is used for the power supply, check the voltage and
current, and install the noise filter as close to the product as
possible.
5. Reception interference may occur if the product is used close to a
radio, television, or wireless.
Digital
Indicator
Surge
absorber
Signal
Digital
input
Indicator
K3HB-R/-P/-C
Digital Indicators
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

K3hb-rK3hb-pK3hb-c

Table of Contents