Outputs
out-p
Comparative Output Pattern
Standard, zone, and level comparative output patterns can be
selected for comparative outputs.
hys
Hysteresis
Prevents comparative outputs from chattering when the
measurement value fluctuates slightly near the set value.
o-stp
Output Refresh Stop
Holds the output status when a comparative result output other than
PASS turns ON.
pass
PASS Output Change
Comparative results other than PASS and error signals can be
output from the PASS output terminal.
off-d
Output OFF Delay
Delays turning OFF comparatives for a set period. This can be used
to provide sufficient time to read the comparative output ON status
when the comparative result changes at short intervals.
shot
Shot Output
Turns ON the comparative output for a specific time.
out-n
Output Logic
Reverses the output logic of comparative results.
s-tmr
Startup Compensation Timer
Measurements can be stopped for a set time using an external input.
test
Output Test
Output operation can be checked without using actual input signals
by using the keys to set a test measurement value.
lset.c, lset.v, lset.h, lset.l
Linear Outputs
R P C
A current or voltage proportional to the change in the measurement
value can be output.
stdby
Standby Sequence
The comparison outputs can be kept OFF until the measurement
value enters the PASS range.
R P C
R
R P
R P
R P C
R P C
R P C
R
R P C
R P
Display
disp
Display Value Selection
The display value can be set to the present value, the maximum
value, or the minimum value.
color
Display Color Selection
The present value display color can be set to green or red. The color
of the present value can also be switched according to the
comparative output.
d.ref
Display Refresh Period
When the input changes rapidly, the display refresh period can be
lengthened to control flickering and make the display easier to read.
pos-t, pos-h, pos-l
Position Meter
R P C
The present measurement value can be displayed as a position in
relation to the scaling width on a 20-gradation position meter.
ps.ax, ps.ay, ps.bx, ps.by
Prescale
R P C
The input signal can be converted and displayed as any value.
sv.dsp
Comparative Set Value Display
Select whether or not to display the comparative value during
operation.
ret
Display auto-return
Automatically returns the display to RUN level when there are no key
operations (e.g., max./min. switching, bank settings using keys).
Other
R P
Max./Min. Hold
Holds the maximum and minimum measurement values.
bnk-c
Bank Selection
Switch between 8 comparative value banks using the keys on the
front panel or external inputs. A set of set comparative values can be
selected as a group.
copy
Bank Copy
Any bank settings can be copied to all banks.
memo
Interruption Memory
The measured value can be recorded when the power supply is
interrupted.
R P C
User Calibration
The K3HB can be calibrated by the user.
K3HB-R/-P/-C
Digital Indicators
R P C
R P C
R P C
R P C
R P C
R P C
R P C
C