Hold Function; Operation In Dip Switch Monitor Mode - Omron H7CX-N Datasheet

Multifunction counter/tachometer h7cx series
Table of Contents

Advertisement

H7CX-R@-N
Precautions for the H7CX-R
In upper and lower limit output mode, if the comparison value setting is such that comparison value 1 comparison value 2, the output will always
be ON.

Hold Function

The measurement value (display value) and output are sustained while the hold input is ON.
Note: The output will maintain the current status when the hold key is pressed.
Example:
Output mode
setting
Lower limit
Comparison value (lower limit)
* The H7CX-R11W@-N does not have a hold input.

Operation in DIP Switch Monitor Mode

The H7CX-R is also equipped with a DIP switch monitor function, a convenient function that enables the settings of the DIP switch pins to be
confirmed using the front display.
Power ON
Run Mode
+
1
1 s min.
DIP Switch
Monitor
Mode
Key
50
Operation
Hold input* (Hold Key)
Display value
OUT
: Measurement stopped
: Measurement possible
*
DIP switch monitor
1
Key
Actual input
Sustained display value
Sustained output
Note: To change the mode to DIP switch monitor mode, press the
for 1 s min. with the
if the
Key is pressed first.
1
The status of the DIP switch pins (1 to 8) can be confirmed using the U Key.
Example
ON
OFF
1 2 3 4 5 6 7 8
* When the mode is changed to DIP switch monitor, the measurement value is reset, outputs turns OFF, and
measuring stops.
Key held down. The mode will not change
...Indicates that DIP switch pin 8 is ON.
...Indicates that DIP switch pin 7 is OFF.
...Indicates that DIP switch pin 6 is ON.
...Indicates that DIP switch pin 5 is OFF.
...Indicates that DIP switch pin 4 is ON.
...Indicates that DIP switch pin 3 is OFF.
...Indicates that DIP switch pin 2 is ON.
...Indicates that DIP switch pin 1 is OFF.
Key
1

Hide quick links: