Operation In Run Mode - Omron H7CX-N Datasheet

Multifunction counter/tachometer h7cx series
Table of Contents

Advertisement

Operation in Run Mode

Tachometer Operation
• Set each digit using the individual U Keys.
Measurement value
Measurement value 1
Comparison value 1
Measurement value 2
Comparison value 2
*3
*1 Measurement value 1 for the 2-input input mode.
*2 Measurement value 2 for the 2-input input mode.
*3 Peak/bottom hold enabled
Displayed when the input mode is not 2 inputs.
Peak hold value
Bottom hold value
• Measurement value
Displays the currently measured value.
• Comparison value 1/Comparison value 2
Set comparison value 1 and comparison value 2.
*1
The measurement value is compared to
comparison value 1 and comparison value 2 and
output is made according to the selected output
mode.
*2
Displayed for the 2-input input mode.
Peak hold value 1
Bottom hold value 1
Peak hold value 2
Bottom hold value 2
H7CX-A@-N
Tachometer
• Peak/bottom hold value
The peak (maximum) and bottom (minimum)
values are displayed after counting starts.
• Peak/bottom hold value 2
Peaks (maximums) 1 and 2 and bottoms
(minimums) 1 and 2 are displayed after counting
starts.
Note: The held values will be initialized when
the Reset Key (Hold Key) or reset 1 input
is turned OFF while peak/bottom hold
values 1 and 2 are being displayed. (The
reset 2 input operates in the same way if
the input mode is set to 2-input mode.)