■ Operation in Run Mode
Set the number for each digit with the

■ Output Mode Settings

Upper and
lower limit
(HI-LO)
Area
(AREA)
Output mode
setting
Upper limit
(HI-HI)
Lower limit
(LO-LO)
22
Multifunction Counter
Up
Keys.
Measurement Value
Measurement value
Displays the currently measured value.
OUT1/OUT2 Set Value
Set OUT1 set value and OUT2 set value. The
Measurement value
measurement value is compared to OUT1 set value
and OUT2 set value and output is made according to
OUT1 set value
the selected output mode.
Measurement value
OUT2 set value
(Upper-limit)
OUT2 set value
Measurement value
(Lower-limit)
OUT1 set value
OUT1
OUT2
OUT2 set value
Measurement value
OUT1 set value
OUT1
OUT2
(Upper-limit)
OUT2 set value
Measurement value
(Upper-limit)
OUT1 set value
OUT1
OUT2
(Lower-limit)
OUT2 set value
Measurement value
(Lower-limit)
OUT1 set value
OUT1
OUT2
H7BX
ON condition for OUT1: Measurement value
ON condition for OUT2: Measurement value
OUT1 set value
Condition
set value
OUT1 set value
ON condition
Measurement value OUT2
for OUT1
set value
Measurement value < OUT1
ON condition
set value or Measurement
for OUT2
value > OUT2 set value
ON condition for OUT1: Measurement value
ON condition for OUT2: Measurement value
ON condition for OUT1: Measurement value
ON condition for OUT2: Measurement value
OUT1 set value
OUT2 set value
OUT2
OUT1 set value > OUT2
set value
OUT2 set value
Measurement value OUT1
set value
Measurement value < OUT2
set value or Measurement
value > OUT1 set value
OUT1 set value
OUT2 set value
OUT1 set value
OUT2 set value

Hide quick links: