Advanced Function Setting Level - Omron E5CN-H Datasheet

Advanced digital temperature controller (48 x 48 mm)
Hide thumbs Also See for E5CN-H:
Table of Contents

Advertisement

Power ON
Manual Control
Level
Operation
Protect Level
Level
Initial Setting
Level
Advanced
Function Setting
Level
Press the O Key for at least 1 s.

Advanced Function Setting Level

o-dp
init
Parameter Initialization
of f
of f
M
M
SP Ramp Time Unit
spru
ret
m
off
M
M
a1lt
rest
Standby Sequence
Reset
a
off
M
M
Auxiliary Output 1
sb1n
a2lt
Open in Alarm
n- o
of f
M
M
sb2n
a3lt
Auxiliary Output 2
Open in Alarm
n-o
of f
M
M
Auxiliary Output 3
sb3n
prlt
Open in Alarm
3
n- o
M
M
sero
hbu
HB ON/OFF
off
on
M
M
Heater Burnout
cjc
hbl
Latch
on
off
M
M
hbh
rlrv
Heater Burnout
Hysteresis
of f
0. 1
M
M
colr
st-b
c
ST Stable Range
red
15 . 0
M
M
α
pv-b
c
alfa
5. 0
0.65
M
M
a1on
at-g
AT Calculated Gain
0
1. 0
M
M
a2on
at-h
AT Hysteresis
c
0
0. 8
M
M
a3on
Limit Cycle MV
lcma
Amplitude
0
20. 0
M
M
a1of
inf
Input Digital Filter
0
0
0. 0
M
M
a2of
pvad
Additional PV Display
0
of f
M
M
a3of
0
M
Adjustment
Bank Setting
Level
Level
Communica-
tions Setting
Level
Input Shift Type
istp
MV Display
i ns1
M
mvse
Automatic Display
MV at Stop and Error
Return Time
Addition
off
M
amad
Auto/Manual Select
Alarm 1 Latch
Addition
on
M
rt
RT
Alarm 2 Latch
of f
M
hsu
HS Alarm Use
Alarm 3 Latch
on
M
hsl
Move to Protect Level
HS Alarm Latch
Time
of f
M
hsh
Input Error Output
HS Alarm Hysteresis
0. 1
M
lba
LBA Detection Time
Cold Junction
Compensation
0
Method
M
MB Command
lbal
c
LBA Level
Logic Switching
8. 0
M
lbab
PV Change Color
c
LBA Band
3.0
M
PV Stable Band
out1
Control Output 1
Assignment
o
M
Alarm 1 ON Delay
out2
Control Output 2
Assignment
n one
M
Alarm 2 ON Delay
sub1
Auxiliary Output 1
Assignment
alm 1
M
Alarm 3 ON Delay
sub2
Auxiliary Output 2
Assignment
a lm2
M
Alarm 1 OFF Delay
csel
Character Select
on
M
Alarm 2 OFF Delay
t-u
Soak Time Unit
m
M
Alarm 3 OFF Delay
Advanced Digital Temperature Controller
PID Setting
Monitor/Setting
Item Level
Level
spdp
alsp
Alarm SP Selection
"PV/SP" Display
Screen Selection
4
sp -m
M
M
sptr
SP Tracking
odsl
MV Display Selection
off
o
M
M
PV Decimal Point
pidi
pvdp
PID Set Automatic
Selection Data
Display
on
pv
M
M
pidh
PID Set Automatic
pvst
PV Status Display
Selection Hysteresis
Function
0.50
off
M
M
p-db
PV Dead Band
c
svst
SV Status Display
Function
0.0
off
M
M
manl
Manual MV
Display Refresh
d.ref
Limit Enable
Period
off
0.25
M
M
pmvd
Control Output 1
ra1m
Direct Setting of
ON/OFF Count
Position Proportional MV
off
0
Monitor
M
M
PV Rate of Change
Control Output 2
pvrp
ra2m
ON/OFF Count
Calculation Period
17
0
Monitor
M
M
csca
Automatic Cooling
Control Output 1
ra1
ON/OFF Count
Coefficient Adjustment
off
0
Alarm Set Value
M
M
Control Output 2
ocu
Heater Overcurrent
ra2
ON/OFF Count
Use
on
0
Alarm Set Value
M
M
ocl
Heater Overcurrent
ON/OFF Counter
rac
Reset
Latch
off
0
M
M
och
Heater Overcurrent
cmov
Move to Calibration
Level
Hysteresis
0.1
0
M
M
E5CN-H