Download Print this page

Specifications - Omron DST1 Datasheet

Devicenet safety system
Hide thumbs Also See for DST1:

Advertisement

Specifications

NE1A-SCPU01
General Specifications
DeviceNet communications
11 to 25 VDC (supplied from communications
power supply voltage
connector)
Unit power supply voltage
20.4 to 26.4 VDC (24 VDC 15% +10%)
I/O power supply voltage
Communica-
tions power
24 VDC, 15 mA
supply
Consumption
current
Internal cir-
cuit power
24 VDC, 230 mA
supply
Overvoltage category
II
Noise immunity
Conforms to IEC 61131-2
Vibration resistance
10 to 57 Hz: 0.35 mm, 57 to 150 Hz: 50 m/s2
Shock resistance
150 m/s2: 11 ms
Mounting method
35-mm DIN Track
Ambient operating tempera-
10 to 55°C
ture
Ambient operating humidity 10% to 95% (with no condensation)
Ambient storage tempera-
40 to 70°C
ture
Degree of protection
IP20
Weight
460 g max.
Safety Input Specifications
Input type
Sinking inputs (PNP)
ON voltage
11 VDC min. between each input terminal and G1
OFF voltage
5 VDC min. between each input terminal and G1
OFF current
1 mA max.
Input current
4.5 mA
DST1-@SL-1
General Specifications
DeviceNet communications
11 to 25 VDC (supplied from communications
power supply voltage
connector)
Unit power supply voltage
20.4 to 26.4 VDC (24 VDC 15% +10%)
I/O power supply voltage
Communica-
Consumption
DST1-ID12SL-1/MD16SL-1: 100 mA
tions power
current
DST1-MRD08SL-1: 110 mA
supply
Overvoltage category
II
Noise immunity
Conforms to IEC 61131-2
Vibration resistance
10 to 57 Hz: 0.35 mm, 57 to 150 Hz: 50 m/s2
DST1-ID12SL-1/MD16SL-1: 150 m/s² 11 ms
Shock resistance
DST1-MRD08SL-1: 100 m/s² 11 ms
Mounting method
35-mm DIN Track
Ambient operating tempera-
10 to 55°C
ture
10% to 95% (with no condensation)
Ambient operating humidity
DST1-MRD08SL-1: 10% to 85% (with no con-
densation)
Ambient storage tempera-
40 to 70°C
ture
Degree of protection
IP20
DST1-ID12SL-1/MD16SL-1: 420 g
Weight
DST1-MRD08SL-1: 600 g
Safety Input Specifications
Input type
Sinking inputs (PNP)
ON voltage
11 VDC min. between each input terminal and G1
OFF voltage
5 VDC min. between each input terminal and G1
OFF current
1 mA max.
Input current
6 mA
Note: For details on operating precautions and other information required to
use the product, be sure to read the following operation manual:
DeviceNet Safety DST1-series Safety I/O Terminals Operation Manual
(Z904)
NE1A/DST1
Safety Output Specifications
Output type
Sourcing outputs (PNP)
Rated output current
0.5 A max. per output
Residual voltage
1.2 V max. between each output terminal and V2
Leakage current
0.1 mA max.
Test Output Specifications
Output type
Sourcing outputs (PNP)
0.7 A max. per output (See note.)
Rated output current
1.2 V max. between each output terminal
Residual voltage
and V1
Leakage current
0.1 mA max.
Note: Total simultaneous ON current: 1.4 A
Standards
Certifying body
Standards
EN954-1:1996, EN60204-1:1997, EN61000-6-2:2001,
EN61000-6-4:2001, EN418:1992, IEC61508 part1-7/
TÜV Rheinland
12.98-05.00, IEC61131-2/02.03, NFPA 79-2002, ANSI
RIA15.06-1999, ANSI B11.19-2003
UL1998 (pending), NFPA79 (pending), UL508, CSA22.2
UL
No14, UL1604
Note: For details on operating precautions and other information required to
use the product, be sure to read the following operation manual:
DeviceNet Safety Network Controller Operation Manual (Z906)
Safety Output Specifications
Output type
Sourcing outputs (PNP)
Rated output current
0.5 A max. per output
Residual voltage
1.2 V max. between each output terminal and V2
Leakage current
0.1 mA max.
Test Output Specifications
Output type
Sourcing outputs (PNP)
Rated output current
0.7 A max. per point
Residual voltage
1.2 V max. between each output terminal and V1
Leakage current
0.1 mA max.
Safety Output Specifications for Realy Outputs
Relays
G7SA-2A2B, EN 50205 Class A
Minimum applicable load
1 mA at 5 VDC
Rated load for a resistive
240 VAC: 2 A, 30 VDC: 2 A
load
Rated load for an inductive
2 A at 240 VAC (cos =0.3),
load
1 A at 24 VDC
5,000,000 operations min. (switching frequency
Mechanical life expectancy
of 7,200 operations/h)
100,000 operations min. (at rated load and
Electrical life expectancy
switching frequency of 1,800 operations/h)
Standards
Certifying body
Standards
EN954-1/12.96, EN60204-1/12.97, EN61000-6-2/10.01,
EN61000-6-4/10.01,EN418/1992, IEC61508 part1-7/
TÜV Rheinland
12.98-05.00,IEC61131-2/02.03, NFPA 79-2002,ANSI
RIA15.06-1999, ANSI B11.19-2003
UL1998, NFPA79, UL508, CSA22.2 No14, UL1604
UL
(DST1-ID12SL-1 and DST1-MD16SL-1 only)
D-7

Advertisement

loading

This manual is also suitable for:

Ne1a