Download Print this page

Specifications - Omron E8EB Manual

General-purpose pressure sensor

Advertisement

E8EB

Specifications

J RATINGS
Item/Model
Supply voltage
Current consumption
Pressure type
Permissible pressure range
Pressure setting range
Withstand pressure
Applicable fluid
Repeat accuracy (ON/OFF output)
Accuracy (linear output)
Hysteresis (linear output)
Differential travel (ON/OFF output)
Linearity (linear output)
Response time
Linear output
ON/OFF output
Load current
Output applied
voltage
Residual voltage
Indicator
Ambient
Operating
temperature
t
t
Storage
Ambient humidity
Operating
Degree of protection
Pressure port
J CHARACTERISTICS
Item/Model
Temperature influence
Voltage influence
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Enclosure rating
Pressure port material
Cable
Weight
2
E8EB-10C
E8EB-10B
24 VDC 10% with a ripple (p-p) of 5% max.
20 mA max.
Positive
0 to 142 psi (0 to 980 kPa)
0 to 142 psi (0 to 980 kPa)
290 psi (2.0 MPa)
Noncorrosive and nonflammable gases
1% FS max.
3% FS max.
1% FS max.
0.4 to 1.6% FS max.
1% FS max.
5 ms max.
1 to 5 V with an output impedance of 20 Ω and a permissible resistive load of 10 kΩ min.
NPN open
PNP open
collector
collector
80 mA max.
30 VDC max.
NPN: 1 V max. (at the load current of 80 mA) and 0.4 V max. (at the load current of 20 mA)
PNP: 2 V max. (at the load current of 80 mA) and 1.5 V max. (at the load current of 20 mA)
Operating indicator (red)
–10 C to 55 C (14 F to 131 F) with no icing
–25 C to 70 C (–13 F to 158 F) with no icing
35% to 85% (with no icing)
IEC60529 IP54
R
(PT) 1/8
C
E8EB-10C, E8EB-10B
0.12% FS/ C between 0 C and 50 C
(32 F and 122 F)
0.2% FS/ C max. between –10 C and 0 C
(14 F and 32 F) or 50 C and 55 C
(122 F and 131 F)
1% FS max.
100 MΩ min. (at 500 VDC) between current carry parts and case
500 VAC for 1 min between current carry parts and case
10 to 500 Hz, 1.5-mm double amplitude or 100 m/s
smaller, for 2 hours each in X, Y, and Z directions
2
2
1,000 m/s
(3280 ft/s
) approx. 3 times each in X, Y, and Z directions
IEC60529 IP54
Zinc die-cast
Vinyl-insulated round cable with four conductors, 3.8 dia.; standard length: 2 m (78.74 in)
Approx. 120 g (4.23 oz)
E8EB-01C
E8EB-01B
0 to 14.2 psi (0 to 98 kPa)
0 to 14.2 psi (0 to 98 kPa)
42 psi (290 kPa)
PNP open
PNP open
collector
collector
E8EB-01C, E8EB-01B, E8EB-N0C2B,
E8EB-N0B2B
0.2% FS/ C between 0 C and 50 C
(32 F and 122 F)
0.3% FS/ C max. between –10 C and 0 C
(14 F and 32 F) or 50 C and 55 C
(122 F and 131 F)
2
2
(328 ft/s
) approx. 10G whichever is
E8EB
E8EB-N0C2B E8EB-N0B2B
Negative
0 to –14.2 psi (0 to –98 kPa)
0 to –14.2 psi (0 to –98 kPa)
42 psi (290 kPa)
NPN open
PNP open
collector
collector

Advertisement

loading

This manual is also suitable for:

E8eb-10cE8eb-10bE8eb-01cE8eb-01bE8eb-n0c2bE8eb-n0b2b