Interrupt Control Instructions - Omron CX-PROGRAMMER 5.0-FUNCTION BLOCK OPERATION Operation Manual

Function blocks
Table of Contents

Advertisement

Instruction Support and Operand Restrictions
Instruction
Mnemonic
GLOBAL SUBROU-
GSBN
TINE ENTRY
GLOBAL SUBROU-
GRET
TINE RETURN

2-6-18 Interrupt Control Instructions

Instruction
Mnemonic
SET INTERRUPT
MSKS
MASK
@MSKS
READ INTERRUPT
MSKR
MASK
@MSKR
CLEAR INTER-
CLI
RUPT
@CLI
DISABLE INTER-
DI
RUPTS
@DI
ENABLE INTER-
EI
RUPTS
Function
Symbol
code
751
Not supported in func-
tion blocks
752
Not supported in func-
tion blocks
Function
Symbol
code
690
692
691
693
694
Operands
N: Subroutine num-
ber
Operands
N: Interrupt identi-
MSKS
fier
N
S: Interrupt data
S
N: Interrupt identi-
MSKR
fier
N
D: Destination word UINT
D
N: Interrupt identi-
CLI
fier
N
S: Interrupt data
S
---
DI
---
EI
Section 2-6
Supported
AT
variable
setting or
data types
array
variable
required
(Required
word data
size
shown in
parenthe-
ses.)
---
---
---
---
Supported
AT
variable
setting or
data types
array
variable
required
(Required
word data
size
shown in
parenthe-
ses.)
# + decimal
---
only
UINT
---
# + decimal
---
only
---
# + decimal
---
only
UINT
---
---
---
---
---
87

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cx-programmer 5.0Sysmac ws02-cxpc1-e-v50Cs1-hCj1-hCj1m

Table of Contents