LevelPro
— ProScan
®
Continuous Radar Level Sensor (80GHz)
Setting Range
Home
ICON12XXX
Level(inch)
35.7873
Distance(inch)
84.2124
Current(mA)
Percentage(%)
Running State
Update Time
2023/11/21 16:29:36
Home
Curve
Set
Click Set Button
Setting Level
Basic Parameters
ICON12XXX
Range(inch)
120.00
0.0
Migration Amount(inch)
0.0
4mA Location(inch)
119.9998
20mA Location(inch)
4.0157
Blind Area(inch)
50
Damping Time
Device Address
Baud Rate
9600
READ
SET
BACKUP
Set
4mA
Location
4mA (Low Level) = 0
Setting Parameters
Basic Parameters
ICON12XXX
Range(inch)
120.00
Migration Amount(inch)
0.0
0.0
4mA Location(inch)
110.00
20mA Location(inch)
4.00
Blind Area(inch)
50
Damping Time
Device Address
1
Baud Rate
9600
READ
SET
BACKUP
RESTORE
Set
Blind Area
E.g. Blind Area = 4.00(Inch)
24-0231 © Icon Process Controls Ltd.
®
Set
ICON12XXX
Basic Parameters
Advanced Parameters
System Settings
8.771
29.82
0
Home
Curve
Select Basic Parameters
1
RESTORE
4 mA
Basic Parameters
ICON12XXX
Range(inch)
Migration Amount(inch)
4mA Location(inch)
20mA Location(inch)
Blind Area(inch)
Damping Time
Device Address
Baud Rate
READ
SET
BACKUP
Set
Damping Time
E.g. Damping Time = 10(sec)
3 Series
ICON12XXX
Range(inch)
Migration Amount(inch)
4mA Location(inch)
20mA Location(inch)
Blind Area(inch)
Damping Time
Device Address
Baud Rate
READ
Set
Set
E.g. Range Value =
ICON12XXX
Range(inch)
Migration Amount(inch)
4mA Location(inch)
20mA Location(inch)
Blind Area(inch)
Damping Time
Device Address
Baud Rate
READ
Set
20mA (High Level) = 110(inch)
Basic Parameters
ICON12XXX
120.00
Range(inch)
0.0
Migration Amount(inch)
0.0
4mA Location(inch)
110.00
20mA Location(inch)
4.00
Blind Area(inch)
10
Damping Time
1
Device Address
9600
Baud Rate
RESTORE
READ
SET
et
Click S
Save the Parameters
Basic Parameters
120.00
0.0
0.0
119.9998
4.0157
50
1
9600
SET
BACKUP
RESTORE
Range
Value
120 (inch)
Basic Parameters
120.00
0.0
0.0
20 mA
110.00
4.0157
50
1
9600
SET
BACKUP
RESTORE
4 mA
20mA
Location
120.00
0.0
0.0
20 mA
110.00
4.00
10
1
9600
BACKUP
RESTORE
4 mA
Button to
Range 120 (inch)
Measurement
Location
100%
Max Config
Range
0%
4
Need help?
Do you have a question about the LevelPro ProScan 3 Series and is the answer not in the manual?