Advertisement

Quick Links

A
FPD-L
III STP C
LVIUM
INK
AMERAS
Deserializer Board FPD-Link III
STP to CSI-2
User Guide
V1.0.1
Allied Vision Technologies GmbH // Taschenweg 2a, 07646 Stadtroda / Germany
2024-Mar-26

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FPD-Link III STP and is the answer not in the manual?

Questions and answers

Summary of Contents for Allied Vision FPD-Link III STP

  • Page 1 FPD-L III STP C LVIUM AMERAS Deserializer Board FPD-Link III STP to CSI-2 User Guide V1.0.1 Allied Vision Technologies GmbH // Taschenweg 2a, 07646 Stadtroda / Germany 2024-Mar-26...
  • Page 2: Read Before Use

    The product can have sharp edges. Intended use Intended use of Allied Vision product is the integration into vision systems by professionals. All Allied Vision product is sold in a B2B setting. Deserializer Board FPD-Link III STP to CSI-2 User Guide V1.0.1...
  • Page 3 Fare for skarpe kanter Produktet kan have skarpe kanter. Tilsigtet brug Allied Vision produktets tilsigtede brug er en indbygning i et visionssystem, udført af fagfolk. Alle Allied Vision produkter sælges i B2B. Deserializer Board FPD-Link III STP to CSI-2 User Guide V1.0.1...
  • Page 4 Das Produkt kann scharfe Kanten haben. Bestimmungsgemäßer Gebrauch Allied Vision Produkte sind bestimmt für die Integration in Bildverarbeitungs- systeme durch Fachpersonal. Alle Allied Vision Produkte werden in einer B2B-Umgebung verkauft. Deserializer Board FPD-Link III STP to CSI-2 User Guide V1.0.1...
  • Page 5 Riesgo de cortes por bordes afilados El producto puede tener bordes afilados. Uso previsto El uso previsto del producto Allied Vision es la integración en el sistema de visión por parte de profesionales. Todos los productos Allied Vision se venden dentro de una relación B2B.
  • Page 6 Käytössä olevan tuotteen saavuttamat lämpötilatasot voivat aiheuttaa palovammoja. HUOMIO Terävien reunojen aiheuttama viiltovaara Tuotteessa voi olla teräviä reunoja. Käyttötarkoitus Allied Vision -tuotteen käyttötarkoitus on integrointi kuvajärjestelmiin ammattilaisten toimesta. Kaikki Allied Vision -tuotteet myydään B2B-ympäristössä. Deserializer Board FPD-Link III STP to CSI-2 User Guide V1.0.1...
  • Page 7 Utilisation prévue L’utilisation prévue du produit Allied Vision est son intégration dans des systèmes de vision par le soin de professionnels. Tout produit Allied Vision est vendu dans un cadre B2B. Deserializer Board FPD-Link III STP to CSI-2 User Guide V1.0.1...
  • Page 8 ‫ר צ‬ ‫ו מ‬ ‫ת‬ ‫ב‬ ‫י ב‬ ‫ס‬ ‫ב‬ ‫ש‬ ‫ו מ‬ ‫י ש‬ ‫ל‬ ‫ם י‬ ‫ר כ‬ ‫מ נ‬ AlliedVision ‫י‬ ‫ר צ‬ ‫ו מ‬ ‫ל כ‬ Deserializer Board FPD-Link III STP to CSI-2 User Guide V1.0.1...
  • Page 9 Pericolo di tagliarsi sui bordi affilati I bordi del prodotto lente possono essere affilati. Uso previsto Il prodotto Allied Vision è concepito per essere integrato in sistemi di monitoraggio in campo professionale. Tutti i prodotti Allied Vision sono venduti in uno scenario B2B.
  • Page 10 Read before use JA - 日本語 安全性 本製品を使用する前に、この安全ガイドをお読みください。警告を必ず 守ってください。必ず21ページのIntended use 24 ページに従って使用し てください。 注意 やけどの危険性 作動中のカメラは、やけどを引き起こす温度まで熱くなる恐れがありま す。 注意 な端部で切り傷の危険性 本製品には鋭利な部分がある場合があります。 用途 Allied Vision製品は、専門家が視覚装置に統合することを意図したもの です。すべてのAllied Vision製品は、企業間取り引き用に販売されてい ます。 Deserializer Board FPD-Link III STP to CSI-2 User Guide V1.0.1...
  • Page 11 Risico van snijwonden door scherpe randen Het product kan scherpe randen hebben. Beoogd gebruik Het beoogde gebruik van het Allied Vision-product is de integratie in optische systemen door professionals. Alle Allied Vision-producten worden verkocht in de B2B-markt. Deserializer Board FPD-Link III STP to CSI-2 User Guide V1.0.1...
  • Page 12 Risiko for kutt fra skarpe kanter Produktet kan ha skarpe kanter. Tiltenkt bruk Den tiltenkte bruken av Allied Vision-produktet er integrering i visjonssystemer av profesjonelle. Alle Allied Vision-produkter selges i en forretning til forretning-situasjon. Deserializer Board FPD-Link III STP to CSI-2 User Guide V1.0.1...
  • Page 13 Risk för skärsår från vassa kanter Produkten kan ha vassa kanter. Avsedd användning Den avsedda användningen av Allied Vision-produkter är integrering i visionssystem av fackmän. Samtliga Allied Vision-produkter säljs i en B2B-miljö. Deserializer Board FPD-Link III STP to CSI-2 User Guide V1.0.1...
  • Page 14 Read before use ZH - 简体中文版 安全需知 Intended 在使用产品之前,请阅读这些安全说明。请务必遵守相关警告 和 于第 24 页 . 注意事项 烫伤风险 在产品运行过程中,温度可能会上升,导致烧伤的危险。 注意事项 锋利边缘割伤的风险 产品可能有锋利的边缘。 预期用途 Allied Vision 产品的预期用途是由专业人士整合到视觉系统中。所有 Allied Vision 的产品均通过 B2B 渠道销售。 Deserializer Board FPD-Link III STP to CSI-2 User Guide V1.0.1...
  • Page 15: This Document At A Glance

    This document at a glance Get an overview of documentation for the Deserializer Board FPD-Link III STP to CSI-2: Note..................16 Shipping contents..............16 What else do you need? ............16 Deserializer Board FPD-Link III STP to CSI-2 User Guide V1.0.1...
  • Page 16: Note

    FPC cables, I/O cables, lenses, and www.alliedvision.com/en/products/accessories tripod adapters SerDes Configurator: Please contact www.alliedvision.com/en/about-us/contact-us/ the Allied Vision Support team at... technical-support-repair-/-rma Table 1: Downloads for Deserializer Board FPD-Link III STP to CSI-2 Deserializer Board FPD-Link III STP to CSI-2 User Guide V1.0.1...
  • Page 17: Contact Us

    102 Pickering Way - Suite 502 Allied Vision Technologies Asia Pte. Ltd Exton, PA 19341, USA 82 Playfair Rd, #07-01 D'Lithium Toll-free// +1-877-USA-1394 Singapore 368001 T// +1 978 225 2030 T// +65 6634 9027 Deserializer Board FPD-Link III STP to CSI-2 User Guide V1.0.1...
  • Page 18: Table Of Contents

    Instructions for connecting ............. . 38 Deserializer Board FPD-Link III STP to CSI-2 User Guide V1.0.1...
  • Page 19 Connecting power ............... . . 42 Deserializer Board FPD-Link III STP to CSI-2 User Guide V1.0.1...
  • Page 20: Document History And Conventions

    Document history and conventions This chapter includes: Document history ..............21 Conventions used in this user guide........21 Component naming .............. 22 Deserializer Board FPD-Link III STP to CSI-2 User Guide V1.0.1...
  • Page 21: Document History

    Links to webpages and internal cross references Table 3: Typographical styles Symbols and notes CAUTION Risk of burns Precautions are described CAUTION Risk of cuts Precautions are described NOTICE Material damage Precautions are described. Deserializer Board FPD-Link III STP to CSI-2 User Guide V1.0.1...
  • Page 22: Component Naming

    Deserializer Board FPD-Link III STP to CSI-2 Example: Embedded board NVIDIA Jetson Xavier NX DevKit Hirose FH55-22S-0.55SH FPC (flexible printed circuit) FPC connector connector FPC cable MIPI CSI-2 FPC cable Table 4: Component naming Deserializer Board FPD-Link III STP to CSI-2 User Guide V1.0.1...
  • Page 23: Compliance, Safety, And Intended Use

    Compliance, safety, and intended use This chapter includes: Compliance notifications ............24 Intended use ................. 24 Copyright and trademarks ............ 24 Your safety................25 Product safety ............... 25 Deserializer Board FPD-Link III STP to CSI-2 User Guide V1.0.1...
  • Page 24: Compliance Notifications

    We are offering standard products as well as customized solutions. Intended use of Allied Vision product is the integration into Vision systems by professionals. All Allied Vision product is sold in a B2B setting.
  • Page 25: Your Safety

    Components can easily be damaged. If you are unfamiliar with FPD-Link III connections or with embedded systems, be extremely careful. Follow the instructions in the Alvium FP3/GM2 User Guide. Deserializer Board FPD-Link III STP to CSI-2 User Guide V1.0.1...
  • Page 26 Compliance, safety, and intended use Allied Vision accessories help to avoid damage to the camera and connected components. Compatible accessories We recommend using accessories by Allied Vision, see www.alliedvision.com/en/ products/accessories. Strain relief for all cable connections If HSD STP connectors are exposed to excessive stress, they can break off from devices.
  • Page 27 If Alvium FP3 STP cameras are operated with incompatible cables, cameras and connected peripherals can be damaged. • We recommend you to use only STP cables by Allied Vision. • If you want to use third party STP cables, observe...
  • Page 28 But the 10-pin TFM connector on Alvium FP3 cameras must not be used as power input. • Use the 10-pin TFM connector only as power output and for I/O control. Deserializer Board FPD-Link III STP to CSI-2 User Guide V1.0.1...
  • Page 29 • You may mount the camera electrically isolated. • Read the Avoiding Ground Loops in Vision Systems application note. More information See the Avoiding Ground Loops in Vision Systems application note at www.alliedvision.com/en/support/technical-documentation/ alvium-csi-2-documentation. Deserializer Board FPD-Link III STP to CSI-2 User Guide V1.0.1...
  • Page 30: Specifications

    Specifications This chapter includes: Specifications overview............31 PCB and PCBA number............32 Technical drawing..............32 Electronic schematics ............33 STP connector pin assignment..........35 Deserializer Board FPD-Link III STP to CSI-2 User Guide V1.0.1...
  • Page 31: Specifications Overview

    If enclosed in a housing, ensure that the component temperatures of U4 and L3 do not exceed 105 °C. Figure 5 on page 32. Table 5: Deserializer Board FPD-Link III STP to CSI-2 specifications overview Specifications of the deserializer chip This deserializer board incorporates the FPD-Link III deserializer chip Texas Instruments DS90UB954-Q1.
  • Page 32: Pcb And Pcba Number

    Figure 4: PCB and PCBA number on deserializer boards Technical drawing 2.6 (4x) 15.90 STP Plug Z Max. 105 °C Figure 5: Deserializer Board FPD-Link III STP to CSI-2 dimensions and PCB layout Deserializer Board FPD-Link III STP to CSI-2 User Guide V1.0.1...
  • Page 33: Electronic Schematics

    STM8S001J3M3 100n XIN / REFCLK VDD_SEL BISTEN VCC3V3D MODE EN-I2C-HOST EXT-GPIO0-I2C-SCL EXT-GPIO0-I2C-SCL_DESER EXT-GPIO1-I2C-SDA EXT-GPIO1-I2C-SDA_DESER VCC3V3D 74LVC2G66GT,115 100n Figure 6: Deserializer Board FPD-Link III STP to CSI-2 electronic schematics, part 1 Deserializer Board FPD-Link III STP to CSI-2 User Guide V1.0.1...
  • Page 34 V_FB = 0.6V +/- 2% 100n TLV62568ADRL Vout: 0.6V - Vin 100k Vin : 2.5V-5.5V Iout : 1A Figure 7: Deserializer Board FPD-Link III STP to CSI-2 electronic schematics, part 2 Deserializer Board FPD-Link III STP to CSI-2 User Guide V1.0.1...
  • Page 35: Stp Connector Pin Assignment

    If Alvium FP3 STP cameras are operated with incompatible cables, cameras and connected peripherals can be damaged. • We recommend you to use only STP cables and deserializers by Allied Vision. • If you want to use third party accessories, observe...
  • Page 36: Setting Up Deserializer Boards

    This chapter includes basic instructions on cable connectors: Connecting HSD STP cables ..........37 Connecting FPC cables ............39 Followed by instructions for: Mounting deserializer boards..........41 Connecting components to each other........ 41 Connecting power..............42 Deserializer Board FPD-Link III STP to CSI-2 User Guide V1.0.1...
  • Page 37: Connecting Hsd Stp Cables

    If Alvium FP3 STP cameras are operated with incompatible cables, cameras and connected peripherals can be damaged. • We recommend you to use only STP cables by Allied Vision. • If you want to use third party STP cables, observe...
  • Page 38: Instructions For Connecting

    You may slightly rotate and tilt the cable-side connector against the device to reduce friction. The camera is disconnected. Figure 11: Pressing down the latch (c) of the HSD STP connector Deserializer Board FPD-Link III STP to CSI-2 User Guide V1.0.1...
  • Page 39: Connecting Fpc Cables

    Figure 14: FPC cable and data flow direction 2. Ensuring proper cable orientation between devices to be connected, take the FPC cable with conductors facing the FPC connector conductors (see Figure 15 on page 40). Deserializer Board FPD-Link III STP to CSI-2 User Guide V1.0.1...
  • Page 40 Actuator 12° 5. Holding the FPC cable in position, flap down the actuator to closed Figure 16: Engaging the FPC cable in the FPC connector position (see Figure 16). Deserializer Board FPD-Link III STP to CSI-2 User Guide V1.0.1...
  • Page 41: Mounting Deserializer Boards

    For connecting cameras to deserializer boards, follow the instructions in Connecting HSD STP cables on page 37. For connecting deserializer boards to the host, follow the instructions in Connecting FPC cables on page 39. Deserializer Board FPD-Link III STP to CSI-2 User Guide V1.0.1...
  • Page 42: Connecting Power

    Figure 17: Connections and jumper settings for power supply 4. Connect the power supplies to the mains power. 5. Power and boot the embedded system. Your vision application is ready for first operation. Deserializer Board FPD-Link III STP to CSI-2 User Guide V1.0.1...

This manual is also suitable for:

19502

Table of Contents