Summary of Contents for hadewe Veloria 2

  • Page 1 Manual Veloria 2 Art. 0985 FB 04-434 Rev. 1 Date: 04.12.2023...
  • Page 2: Table Of Contents

    Directory Foreword Safety Instructions Cleaning & Disinfection Getting to Know the Unit Before First Use Area of Application Startup Procedure Work Steps Working Positioning Suction Exchange Micro Filter Exchange Control Unit Filter Clamping the Bur/Tool Adjusting the Speed Foot Switch Maintenance &...
  • Page 3: Foreword

    Short description of functions The Veloria 2 is a device for the treatment of callus and nails. The handpiece is compat- ible with rotating tools such as diamond polishers, steel cutters and ceramic cutters.
  • Page 4: Safety Instructions

    Safety Instructions The installation of the working area has to corre- spond to the relevant regulations. Set up the unit in such a way, that the air slits are not blocked and the extracted air can escape well. To avoid the risk of electrocution only connect the device to the mains power supply.
  • Page 5 Safety Instructions When working with materials, which might create dust or moisture, use a drilling unit with suction or spray technique. Wear a nose and mouth pro- tection. Always follow the safety instructions, pro- vided by the manufacturer of the materials being formed and used.
  • Page 6 Safety Instructions To ensure that the bur/tool sits firmly in the chuck, do not work with tools which • have an oily shaft, • are worn, • are bent. Before using the equipment, assure that • the tool can be pushed far enough into the chuck (Test this with a dipstick and clean if necessary.), •...
  • Page 7 Safety Instructions Only use the suction function if you have installed the suction filter. Check this filter every 10 oper- ating hours. If it is full, please exchange it. A filter should be exchanged at least after 50 operating hours. Never use the suction to vacuum any liquids (or air/water fog which contains particles of liquids).
  • Page 8: Cleaning & Disinfection

    Cleaning & Disinfection The device is designed to be compatible with rotating instru- ments which do not penetrate the skin or mucosal or inad- vertently may still cause injuries. For this application please adhere to the cleaning and disinfection instructions provided below. After every treatment please carry out these steps: •...
  • Page 9: Getting To Know The Unit

    Getting to Know the Unit decrease the suction output increase the suction output reduce the speed increase the speed display of speed/suction level change direction of rotation LED is on during reverse rotation main switch memory button m1 memory button m2 START/STOP-button ON/OFF button (standby) connecting socket for foot switch...
  • Page 10: Before First Use

    Before First Use Please read through the instructions Startup Procedure carefully before using the unit and The working area must conform to carefully note the safety advice. Al- the conditions described. Set up the ways keep this manual accessible to unit in such a way, that the air slits any users of the drill.
  • Page 11 Before First Use If you have a foot switch, insert its Take up the handpiece. Should the plug into the port on the right of the handpiece be twisted by the hose device which displays this symbol you can adjust that at the control unit.
  • Page 12: Use

    suction power you can start working. Work Steps If you want to take a break press the In the following section the order in start/stop-button (11). The hand- which you should use the device is piece motor and suction will turn off. described.
  • Page 13: Working Positioning

    Work Positioning The following images are examples of how to work on various parts of the foot. Always make sure that the foot is firmly gripped and that you can work freely and without strain.
  • Page 15: Suction

    filter in the middle to prevent it from Suction bending and sliding off (see picture Switch on the suction with button (2). below). The suction output can be regulated in 5 levels. You will see the selected level in the display. Level 0 would mean that the suction is turned off.
  • Page 16: Clamping The Bur/Tool

    Foot Switch Operation of the foot switch Only use the original hadewe foot switch (art. 0970) to avoid damages. Insert the plug of the foot switch into Now insert the tool as far as possi- the socket with this symbol ble.
  • Page 17: Maintenance & Care

    Maintenance & Care Cleaning the Chuck In the process of time, some dirt might collect itself within the hand- piece and might affect its functions. Therefore, the chuck has to be cleaned monthly. How to remove the chuck Screw off the top of the handpiece To assemble the chuck, follow the with the spanner shown in the pic- steps in reverse order.
  • Page 18: Maintenance Overview

    Maintenance & Care sure you let it dry well afterwards. Cover your index finger with a very little amount (just a drop) of oil and rub in between your thumb and in- dex finger. Dab off the oil until your fingers is only covered with a very thin film of oil.
  • Page 19: Handling Instructions

    A second of rust. In cases in which a disadvantage is the stronger impact rust infestation was found within the...
  • Page 20: Troubleshooting

    Foot switch is used constantly or faulty. → Pull out the socket of the hadewe Bur Shaft Tester (art. 4990) to see if it is bent. the foot switch to see if this is the cause.
  • Page 21: Technical Data

    2014/30/EU directive EMC fuse Sec.: Thermal fuse 2014/35/EU low voltage directive protection class I accuracy of speed display: ±10% hadewe GmbH – Grambartstraße 10 – 30165 Hannover handpiece: type B applied part diameter: 19 - 25 mm Accessories & Spare Parts length: 144 mm speed: 6.000 - 40.000 rpm...
  • Page 22 Old devices bought in Germany that correspond to the electronic device air pressure: permissible law should be sent directly to the range manufacturer (hadewe). We will dis- air humidity: permissible pose of the device free of charge. range The devices should not be taken to public disposal plants (WEEE Reg.-...
  • Page 24 GmbH Grambartstraße 10 30165 Hannover Germany info@hadewe.de www.hadewe.de...