Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Because of this difference, and also because of the wide variety of uses for solid state equipment, all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable.
Safety Instructions Please read this manual and the related documentation thoroughly and familiarize yourself with the directions before installing, operating, performing inspection and preventive maintenance. Make sure to follow the directions correctly to ensure normal operation of the product and your safety. •...
Page 6
• Do not apply an impact to the terminal blocks or the WARNING product itself when the power is on. Otherwise, it may cause malfunction and failure of the product, or electrical shock. • Operate and keep the product under the allowed conditions directed in product specifications.
Overview Base Controllers Catalog Input I/O specifications Remarks number power 16-point dc input NX7-28ADR 12-point relay output • Built-in 9k steps memory 16-point dc input 100 to NX7-28ADT 12-point transistor output • Several µs per step 240V ac processing speed...
Catalog Input I/O specifications Remarks number power • 16-point 24V dc input 24V dc 16-point dc input NX7-28EDR power • 12-point relay output 12-point relay output supply 2A per point • 16-point 24V dc input 24V dc 16-point dc input •...
(Used for hand-held programmer and multi- drop connections, etc.) Disables termination for RS-485 communication Enables termination for RS-485 communication • Use of the COM1 DIP switch is applicable for NX7 IMPORTANT controllers only. NX7s controllers support RS232C only on COM1.
Installation Installation Environment Do not install your PLC system if any of the following ATTENTION conditions are present. • Ambient temperature outside the range of 0 to 55° C (32 to 131° F). • Direct sunlight. • Humidity outside the range of 30% to 85% (non- condensing) •...
Before powering on ATTENTION Make sure to follow these directions before powering on your PLC system. • When installing the system, ensure that there are no metal chips or conductive fragments that stick to wiring cables. • Ensure that power supply and I/O wirings and power supply voltage are all correct.
Mounting Dimensions 10-, 14-, 20- and 28-point 40- and 48-point controllers controllers unit: mm 146.0 mm 100 mm Φ 4.2 Φ 4.2 126.0 mm 81.0 mm 90 mm 90 mm (4.96 in) (3.19 in) 87.0 mm 87.0 mm (3.43 in) (3.43 in) Mounting Spacing Allow at least 50 mm (2 in.) space on all sides of the controller for adequate...
Wiring Wire Requirements • Use the terminals that comply with the specifications given below. • Set terminal wiring torque to from 5 to 7kgfcm. • Use wiring cables of #16 to #22 AWG. Terminal size = 6.35 mm (0.25 in) or less L = 6.35 mm (0.25 in) or less Solderless terminal Wiring torque...
Power Supply Wiring Make sure to connect to the controller system a stable power that has voltage fluctuations within 10% deviation from the rated input voltage. The frame ground terminal must be grounded with Class 3 (100 or less of ground Ω...
• Using a two-wire sensor may needs an additional circuit configuration so that total current consumption does not exceed the allowable current consumption. • For all NX7 and NX7s controllers, all the commons on the input terminal block are isolated internally each other.
IMPORTANT • “NC” terminals are not intended for use as connection points. • For all relay output controllers (NX7-xxxxR and NX7s- xxxxR controllers), all the commons on the output terminal block are isolated internally each other. • For all transistor output controllers (NX7-xxxxT and...
Page 17
16.0 16.1 16.2 16.4 16.6 60 to 400mA load 16.3 16.5 16.7 10 to 30V dc Internal 0V 10 to 30V dc NX7-28ADR, NX7s-28ADR Output Wiring Diagrams Internal circuit 16.0 16.1 16.2 16.4 16.6 17.0 17.2 16.3 16.5 16.7 17.1 17.3...
Specifications General Specifications Item Specifications Operating 0 to 55° C Temperature Storage -20 to 70° C Humidity Operating 10 to 90% RH (Non-condensing) 1500V ac for 1 minute between external terminal (ac) and frame ground (FG) Withstand voltage 500V ac for 1 minute between external terminal (dc) and frame ground (FG) Allowed momentary power 20 ms or less...
Power Supply Specifications Item AC input power DC input power Rated voltage 100 to 240V ac, free voltage 24V dc Allowable voltage range 85 to 264V ac 24V ± 10% dc Rated current 33 Watts 33 Watts consumption Input power frequency 47 to 63 Hz Inrush current 3A or less...
Performance Specifications Controller NX7 SERIES NX7s SERIES Control method Stored program, cyclic operation Base 28/48 points. 28 expansion points. External Input/output Expandable to up to Expansion unsupported two expansion modules Basic 28 types Instructions Advanced 139 types Basic Several µs per step...
Page 23
Controller NX7 SERIES NX7s SERIES 1 channel/32 bits built-in, single phase 8K, two- High-speed counter phase 4K Built-in 5 KHz 2 channels (TR output controllers) Special PTO 10 KHz (with firmware version 2.1 or later) functions Pulse output Acceleration/Deceleration (with firmware version 2.1 or later)
Input Specifications Item DC input Input type DC voltage Insulation method Photocoupler Rated input voltage 12 to 24V dc Voltage range 10.8 to 26.4V Max. input current 10 mA or less Min. On voltage/current 10.0V or more/3.0 mA or more Max.
Communication Specifications COM1 DIP Switch COM1 (9-pin female D-Sub) NX7 controllers (applicable for only) COM2 (8-pin female RJ45) Comm. Status LEDs (Flashes during communication) RS-232C/RS-485 Termination select switch resistance setting switch Item Specifications COM1: RS-232C or RS-485, 9-pin D-Sub •...
Page 28
The terminals #1 and #3, and #2 and #4 are 232C/RXD connected internally, 232C/TXD respectively Use NX_CBLCPU02 or NX_CBLCPU05 cable from your IMPORTANT personal computer's serial port to COM1 port. See NX7 Controllers User Manual for more information about wiring.
Page 56
OE M Controls Trademarks not belonging to OE M Controls are www.oemax.com property of their respective companies. Publication OEMax-NX7-IN001C-MU-P - August 2005 Supersedes Publication NX7-IN001B-MU-P - June 2005 Copyright ® 2005 OE M Controls. All rights reserved. Printed in Korea.