NX7/NX7s Controllers
Installation Instructions
Contents
English ................................. 3
中文 ..................................... 29
Maximum Value for OEMs
SM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NX7 and is the answer not in the manual?

Questions and answers

Summary of Contents for OE Max Controls NX7

  • Page 1 Maximum Value for OEMs NX7/NX7s Controllers Installation Instructions Contents English ......... 3 中文 ........29...
  • Page 3: Table Of Contents

    English Contents Important User Information ..............4 Safety Instructions .................. 5 Overview ....................7 Base Controllers ................7 Expansion Modules ................. 8 Programming Software ..............8 Cables ....................8 Hardware Features ................. 9 Installation ..................... 10 Installation Environment ............... 10 Controller Dimensions ..............
  • Page 4: Important User Information

    Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Because of this difference, and also because of the wide variety of uses for solid state equipment, all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable.
  • Page 5: Safety Instructions

    Safety Instructions Please read this manual and the related documentation thoroughly and familiarize yourself with the directions before installing, operating, performing inspection and preventive maintenance. Make sure to follow the directions correctly to ensure normal operation of the product and your safety. •...
  • Page 6 • Do not apply an impact to the terminal blocks or the WARNING product itself when the power is on. Otherwise, it may cause malfunction and failure of the product, or electrical shock. • Operate and keep the product under the allowed conditions directed in product specifications.
  • Page 7: Overview

    Overview Base Controllers Catalog Input I/O specifications Remarks number power 16-point dc input NX7-28ADR 12-point relay output • Built-in 9k steps memory 16-point dc input 100 to NX7-28ADT 12-point transistor output • Several µs per step 240V ac processing speed...
  • Page 8: Expansion Modules

    Catalog Input I/O specifications Remarks number power • 16-point 24V dc input 24V dc 16-point dc input NX7-28EDR power • 12-point relay output 12-point relay output supply 2A per point • 16-point 24V dc input 24V dc 16-point dc input •...
  • Page 9: Hardware Features

    (Used for hand-held programmer and multi- drop connections, etc.) Disables termination for RS-485 communication Enables termination for RS-485 communication • Use of the COM1 DIP switch is applicable for NX7 IMPORTANT controllers only. NX7s controllers support RS232C only on COM1.
  • Page 10: Installation

    Installation Installation Environment Do not install your PLC system if any of the following ATTENTION conditions are present. • Ambient temperature outside the range of 0 to 55° C (32 to 131° F). • Direct sunlight. • Humidity outside the range of 30% to 85% (non- condensing) •...
  • Page 11: Controller Dimensions

    Before powering on ATTENTION Make sure to follow these directions before powering on your PLC system. • When installing the system, ensure that there are no metal chips or conductive fragments that stick to wiring cables. • Ensure that power supply and I/O wirings and power supply voltage are all correct.
  • Page 12: Mounting Dimensions

    Mounting Dimensions 10-, 14-, 20- and 28-point 40- and 48-point controllers controllers unit: mm 146.0 mm 100 mm Φ 4.2 Φ 4.2 126.0 mm 81.0 mm 90 mm 90 mm (4.96 in) (3.19 in) 87.0 mm 87.0 mm (3.43 in) (3.43 in) Mounting Spacing Allow at least 50 mm (2 in.) space on all sides of the controller for adequate...
  • Page 13: Wiring

    Wiring Wire Requirements • Use the terminals that comply with the specifications given below. • Set terminal wiring torque to from 5 to 7kgfcm. • Use wiring cables of #16 to #22 AWG. Terminal size = 6.35 mm (0.25 in) or less L = 6.35 mm (0.25 in) or less Solderless terminal Wiring torque...
  • Page 14: Power Supply Wiring

    Power Supply Wiring Make sure to connect to the controller system a stable power that has voltage fluctuations within 10% deviation from the rated input voltage. The frame ground terminal must be grounded with Class 3 (100 or less of ground Ω...
  • Page 15: Input Wiring Diagrams

    • Using a two-wire sensor may needs an additional circuit configuration so that total current consumption does not exceed the allowable current consumption. • For all NX7 and NX7s controllers, all the commons on the input terminal block are isolated internally each other.
  • Page 16: Output Wiring Diagrams

    IMPORTANT • “NC” terminals are not intended for use as connection points. • For all relay output controllers (NX7-xxxxR and NX7s- xxxxR controllers), all the commons on the output terminal block are isolated internally each other. • For all transistor output controllers (NX7-xxxxT and...
  • Page 17 16.0 16.1 16.2 16.4 16.6 60 to 400mA load 16.3 16.5 16.7 10 to 30V dc Internal 0V 10 to 30V dc NX7-28ADR, NX7s-28ADR Output Wiring Diagrams Internal circuit 16.0 16.1 16.2 16.4 16.6 17.0 17.2 16.3 16.5 16.7 17.1 17.3...
  • Page 18 NX7-28ADT, NX7s-28ADT Output Wiring Diagrams Internal circuit 16.0 16.1 16.2 16.4 16.6 17.0 17.2 16.3 16.5 16.7 17.1 17.3 24V dc internal power 16.0 16.1 16.2 16.4 16.6 17.0 17.2 60 to 400mA load 16.3 16.5 16.7 17.1 17.3 10 to 30V dc...
  • Page 19 17.5 17.7 16.0 16.1 16.2 16.4 16.6 17.0 17.2 17.4 17.6 16.3 16.5 16.7 17.1 17.3 17.5 17.7 NX7-48ADR, NX7s-48ADR Output Wiring Diagram 16.0 16.1 16.2 16.4 16.6 17.0 17.2 17.4 17.6 18.0 18.2 16.3 16.5 16.7 17.1 17.3 17.5 17.7...
  • Page 20: Specifications

    Specifications General Specifications Item Specifications Operating 0 to 55° C Temperature Storage -20 to 70° C Humidity Operating 10 to 90% RH (Non-condensing) 1500V ac for 1 minute between external terminal (ac) and frame ground (FG) Withstand voltage 500V ac for 1 minute between external terminal (dc) and frame ground (FG) Allowed momentary power 20 ms or less...
  • Page 21: Power Supply Specifications

    Power Supply Specifications Item AC input power DC input power Rated voltage 100 to 240V ac, free voltage 24V dc Allowable voltage range 85 to 264V ac 24V ± 10% dc Rated current 33 Watts 33 Watts consumption Input power frequency 47 to 63 Hz Inrush current 3A or less...
  • Page 22: Performance Specifications

    Performance Specifications Controller NX7 SERIES NX7s SERIES Control method Stored program, cyclic operation Base 28/48 points. 28 expansion points. External Input/output Expandable to up to Expansion unsupported two expansion modules Basic 28 types Instructions Advanced 139 types Basic Several µs per step...
  • Page 23 Controller NX7 SERIES NX7s SERIES 1 channel/32 bits built-in, single phase 8K, two- High-speed counter phase 4K Built-in 5 KHz 2 channels (TR output controllers) Special PTO 10 KHz (with firmware version 2.1 or later) functions Pulse output Acceleration/Deceleration (with firmware version 2.1 or later)
  • Page 24: Input Specifications

    Input Specifications Item DC input Input type DC voltage Insulation method Photocoupler Rated input voltage 12 to 24V dc Voltage range 10.8 to 26.4V Max. input current 10 mA or less Min. On voltage/current 10.0V or more/3.0 mA or more Max.
  • Page 25: Output Specifications

    NX7-28xxR NX7s-10xxR NX7-48xxR Catalog number NX7s-14xxR NX7s-40xxR NX7s-20xxR NX7s-48xxR NX7s-28xxR 12 points for NX7-28xxR 4 points for NX7s-10xxR 20 points for NX7-28xxR Output points 6 points for NX7s-14xxR 16 points for NX7s-20xxR 8 points for NX7s-20xxR Insulation method Relay insulation...
  • Page 26 NX7-28xxT NX7s-10xxT NX7-48xxT Catalog number NX7s-14xxT NX7s-40xxT NX7s-20xxT NX7s-48xxT NX7s-28xxT 12 points for NX7-28xxT 4 points for NX7s-10xxT 20 points for NX7-28xxT Output points 6 points for NX7s-14xxT 16 points for NX7s-20xxT 8 points for NX7s-20xxT Insulation method Photocoupler Rated load voltage...
  • Page 27: Communication Specifications

    Communication Specifications COM1 DIP Switch COM1 (9-pin female D-Sub) NX7 controllers (applicable for only) COM2 (8-pin female RJ45) Comm. Status LEDs (Flashes during communication) RS-232C/RS-485 Termination select switch resistance setting switch Item Specifications COM1: RS-232C or RS-485, 9-pin D-Sub •...
  • Page 28 The terminals #1 and #3, and #2 and #4 are 232C/RXD connected internally, 232C/TXD respectively Use NX_CBLCPU02 or NX_CBLCPU05 cable from your IMPORTANT personal computer's serial port to COM1 port. See NX7 Controllers User Manual for more information about wiring.
  • Page 29 目录 重要用户信息 ..................30 安全说明 ....................31 概述 ......................33 基本控制器 ..................33 扩展模块 ..................34 编程软件 ..................34 电缆 ....................34 硬件功能 ....................35 安装 ......................36 安装环境 ..................36 控制器尺寸 ..................37 安装尺寸 ..................38 安装间隙 ..................38 接线...
  • Page 30 固态电子设备的运行特性不同于机电设备。由于存在这种差异,而且,由于固态电子 设备具有各种不同的用途,因此,所有负责应用该设备的人必须自己确保,此设备的 每种预期用途都是可以接受的。 在任何情况下,OE M Controls 对因使用或应用此设备导致的间接损害或继发性损 害均不承担任何责任。 本手册中包含的示例和图示只用于说明目的。由于任何特定安装都具有许多相关的可 变因素和要求,因此,OE M Controls 不对基于示例和图示的实际使用承担任何责 任。 至于使用本手册中描述的信息、电路、设备或软件, OE M Controls 不承担任何专 利责任。 如果没有 OE M Controls 的书面批准,禁止全部或部分复制本手册的内容。 在整个手册中,我们将使用各种标记来提醒您注意安全方面的事项。 表示可能导致严重人身伤害或死亡、财产损失或经济损失的做 法或情况的信息。 表示对成功应用和了解本产品至关重要的信息。 表示可能导致轻微人身伤害、财产损失、经济损失或产品失灵 的做法或情况的信息。不过,根据实际情况,不遵守附有此符 号的指示可能也会导致严重后果。...
  • Page 31 在安装、操作、进行检查和预防性维护之前,请通阅本手册和相关文档,并熟悉手册 中的相关说明。务必正确遵循说明进行操作,以确保产品正常运转和您的安全。 • 在设计使用本产品的系统时,应根据安装要求,针对外部环 境变化、电源故障和噪声等因素采取适当的预防措施。应设 计和实施相应的外部电路,以使系统在出现任何故障的情况 下都能安全连续地运转。 • 在进行安装、接线、检查、维护和清洁之前,请务必断开产 品的外部电源。切勿在电源接通时触摸电源端子。否则,可 能导致电击事故。 • 不要将使用交流电的产品连接到 DC I/O 端子。不要将外部 供电的产品连接到内部 24V DC 输出端子。 • 如果您需要在产品运行期间执行特殊操作,如程序编辑、运 行控制或强制输出,请务必在确保安全的情况下进行操作。 • 当本产品正在运行时,请不要外部设备或采用内部电源的手 持式编程器 (HHP) 与之相连。在进行连接之前,请务必停止 系统并确保安全。 • 在配置应急保护断路器时,请确保使用外部设备保护 PLC。 • 当自诊断功能检测到错误 (如内部算法错误、监视时间错 误和 / 或连接故障)时,将继续向控制器的电源供电,因此 系统仍然可以运转。应通过设计和配置相应的电路,确保 您的系统在这些条件下仍能安全运行。 •...
  • Page 32 • 不要在接通电源时碰撞端子块或产品本身。否则,可能导致 产品失灵或出现故障,或发生电击事故。 • 请在满足产品规格所要求的条件下操作和保存产品。在安装 期间,一定要避免任何碎片 (金属碎屑、线端头等)落进产 品内部。 • 不要让产品接触高温、高湿度、浓尘条件、盐、金属碎屑、 腐蚀性气体、易燃气体、溶剂、研磨油和 / 或曝露在阳光直 射下。 • 避免与其他物体发生碰撞和震动。否则,可能导致产品着 火、损坏、失灵或老化。 • 按照接线说明固定电缆。建议您不要将线缆连接到标有符号 “ ”的端子。 • 在用端子块接线时,请使用以下规格:螺钉:3.0 M,扭矩: 0.5 牛顿·米 (5 千克力·厘米)端子宽度:6.35 毫米或更 小 (0.25 英寸) • 输入 / 输出电缆和通信电缆应该与电源电缆分开放置。 至少留 出 200 毫米的间隔。否则,产生的噪声可能导致产品失灵。 •...
  • Page 33 16 点 DC 模块 NX7-28ADR 12 点继电器输出 16 点 DC 输入 NX7-28ADT 100 至 12 点晶体管输出 240V AC 内置 9K 步存储器 • 电源 28 点 DC 输入 NX7-48ADR 处理速度达到若干 µs/ 步 20 点继电器输出 • 1 个内置 HSC 输入通道 • 28 点 DC 输入...
  • Page 34 16 点 24V DC 输入 • 24V DC 16 点 DC 输入 NX7-28EDR 12 点继电器输出 • 电源 12 点继电器输出 2A/ 点 16 点 24V DC 输入 • 16 点 DC 输入 24V DC NX7-28EDT 12 点晶体管输出 • 电源 12 点晶体管输出...
  • Page 35 关断 启用 COM1 的 RS-485 通信 接通 (用于手持式编程器和多点连接等) 禁用 RS-485 通信的终端 关断 启用 RS-485 通信的终端 接通 • COM1 DIP 开关仅适用于 NX7 控制器。 NX7s 控制器只在 COM1 上支持 RS232C。 • 系统将自动检测波特率,并将其调整在 4800 至 38400 bps 范围内。如果超过一分钟未进行任何通信,则系统自动检测 速度,并重新进行配置。 • 通信线缆所连的控制器和外围设备之间可能出现通信干扰或 信号失真等问题,为此在通信线缆的末端连接了端接电阻以 消除上述现象。 • 在 COM2 端口处连接外部连接器,以起到端接作用。...
  • Page 36 下列任何场合都不适合安装 PLC 系统。 • 环境温度超出 0 至 55° C (32 至 131° F)的范围。 • 阳光直射处。 • 湿度超出 30% 至 85% (无冷凝)的范围。 • 周围存在可能影响电子零件的化学品。 • 浓尘场所或存在导电尘埃或含盐物质的场所。 • 受高电压、强磁场或强电磁影响的场所。 • 直接碰撞和剧烈振动。 静电释放 在干燥的情况下,可能会释放出强烈的静电。在接触控制器系 统模块之前,请务必触摸接地的金属物体以消除释放的静电。 清洁 切勿使用稀释剂等化学品,因为这类物品会使 PCB 板软化、 变形或褪色。 用电须知 • 只有在 I/O 设备和电机设备启动后,才能运行 PLC 系统。 (例如,首先在...
  • Page 37 、 、 和 点控制器 79.0 毫米 100 毫米 90 毫米 35 毫米 DIN 电轨 76.6 毫米 和 点控制器 79.0 毫米 146 毫米 90 毫米 35 毫米 电轨 76.6 毫米...
  • Page 38 、 、 和 点控制器 和 点控制器 单位:毫米 146.0 毫米 100 毫米 Φ 4.2 Φ 4.2 126.0 毫米 81.0 毫米 90 毫米 90 毫米 (4.96 英寸) (3.19 英寸) 87.0 毫米 87.0 毫米 (3.43 英寸) (3.43 英寸) 如下图所示,在控制器的四周至少留出 50 毫米 (2 英寸)的间隙,以便充分散热。 上...
  • Page 39 • 请使用下列规格的端子。 • 端子的接线扭矩设置在 5 至 7kgfcm 的范围内。 • 使用规格为 #16 到 #22 AWG 的接线线缆。 端子尺寸 宽度 = 6.35 毫米 (0.25 英寸)或更小 宽 宽 长度 = 6.35 毫米 (0.25 英寸)或更小 无焊剂端子 接线扭矩 0.5 至 0.7 Nm M3.0 (5 至 7 kgfcm) 利用端子块接线时,端子的接线扭矩应设置在指定的范围内...
  • Page 40 确保控制器系统与稳定的电源相连,该电源的电压波动范围不超出额定输入电压的 10%。机架地线端子必须用 3 类 (接地电阻为 100 或更低)或 D 类接地装置进行 Ω 接地,以防止机架地线和电源输入端子之间的电压相混。 Ω 使用专用的 3 类 (接地电阻为 100 或更低)或 D 类接地装置将机架接地 绝缘变压器 噪音滤 端子接地。 波器 电源源 注:如果绝缘变压器的二次绕组侧和噪音滤波器远离控制器系统,而且噪音过大,则没有任何明显 的效果。...
  • Page 41 在以下输入接线图中: • “NC”端子并没有用作连接点。 • 使用双线传感器时可能需要对电路进行额外配置,以使总的 电流消耗不超过允许的电流消耗。 • 对于所有 NX7 和 NX7s 控制器,输入端子块的所有 COMMON 都在内部相互隔离。 使用 点控制器的 接线示例 -COM 双线传感器 传感器 传感器 DC24V DC24V 现场 现场 内部电路 内部电路 DC24V DC24V 传感器 使用 点控制器的 接线示例 +COM 双线传感器 传感器 传感器 DC24V DC24V 现场...
  • Page 42 在以下输出接线图中: • “NC”端子并没有用作连接点。 • 对于所有继电器输出控制器 (NX7-xxxxR 和 NX7s-xxxxR 控 制器) ,输出端子块的所有 COMMON 都在内部相互隔离。 • 对于所有晶体管输出控制器 (NX7-xxxxT 和 NX7s-xxxxT 控 制器) ,输出端子块的所有 COMMON 都在内部互连,即没 有相互隔离。 输出接线图 NX7s-10ADR 内部电路 100-240VAC Power 16.0 16.1 16.2 16.3 16.0 16.1 16.2 16.3 负载 5 至 30V DC 100/220V AC 输出接线图...
  • Page 43 内部电源 16.0 16.1 16.2 16.4 16.6 60 至 400mA 负载 16.3 16.5 16.7 10 至 30V DC 内部 0V 10 至 30V DC 、 输出接线图 NX7-28ADR NX7s-28ADR 内部电路 16.0 16.1 16.2 16.4 16.6 17.0 17.2 16.3 16.5 16.7 17.1 17.3 16.0...
  • Page 44 、 输出接线图 NX7-28ADT NX7s-28ADT 内部电路 16.0 16.1 16.2 16.4 16.6 17.0 17.2 16.3 16.5 16.7 17.1 17.3 24V DC 内部电源 16.0 16.1 16.2 16.4 16.6 17.0 17.2 60 至 400mA 负载 16.3 16.5 16.7 17.1 17.3 10 至 30V DC 内部...
  • Page 45 17.5 17.7 16.0 16.1 16.2 16.4 16.6 17.0 17.2 17.4 17.6 16.3 16.5 16.7 17.1 17.3 17.5 17.7 、 输出接线图 NX7-48ADR NX7s-48ADR 16.0 16.1 16.2 16.4 16.6 17.0 17.2 17.4 17.6 18.0 18.2 16.3 16.5 16.7 17.1 17.3 17.5 17.7 18.1...
  • Page 46 运行 0 至 55° C 温度 储存 -20 至 70° C 湿度 运行 10 至 90% RH (无冷凝) 在外部端子 (AC) 和机箱地线 (FG) 之间 1500V AC 持续 1 分钟 耐电压性 在外部端子 (DC) 和机箱地线 (FG) 之间 500V AC 持续 1 分钟 电源故障的允许时限 20 ms 或更短...
  • Page 47 额定电压 100 至 240V AC,电压等级可 24V DC 选择 电压容许范围 85 至 264V AC 24V ± 10% DC 额定功耗 33 W 33 W 输入电源频率 47 至 63 Hz 浪涌电流 3A 或更低 5A 或更低 内部电源: 内部电源: 2.0A/5V 2.0A/5V 额定输出电流 外部输出: 外部输出: 0.4A/24V 0.4A/24V AC 电源电路配置...
  • Page 48 NX7s 控制方法 存储程序、循环操作 28/48 个基本点。 28 个扩 展点。 外部输入 / 输出 不支持扩展 最多可扩展到两个扩展模 块 基本 28 种 指令 高级 139 种 若干 µs/ 步 基本 处理 速度 数到数十 µs/ 步 高级 程序处理能力 9k 字 2k 字 R000.00 至 R31.15 (512 点, 32 字) I/O (R) 内部专用...
  • Page 49 NX7s 内置 不支持 其他 支持 8 回路 PID 控制功能 不支持 支持适用于 Windows 的 支持适用于 Windows 的 编程工具 编程软件 或更高版本 WinGPC 3.8 或更高版本 WinGPC 使用闪存存储器进行 电池备份系统,使用闪存 备份 (NX7s-10xxx 存储器备份 ROM 进行备份 和 NX7s-14xxx 不需 要电池。 )...
  • Page 50 输入类型 DC 电压 绝缘方法 光电耦合器 额定输入电压 12 至 24V DC 电压范围 10.8 至 26.4V 最大输入电流 10 mA 或更小 最小接通电压 / 电流 10.0V 或更高 /3.0 mA 或更大 最大关断电压 / 电流 5V 或更低 /0.6 mA 或更小 输入阻抗 大约 3.6 K 关断 → 接通 2 ms 或更短...
  • Page 51 继电器输出 NX7-28xxR NX7s-10xxR NX7-48xxR 目录号 NX7s-14xxR NX7s-40xxR NX7s-20xxR NX7s-48xxR NX7s-28xxR NX7-28xxR, 12 点 NX7s-10xxR, 4 点 20 点, NX7-28xxR 输出点数 NX7s-14xxR, 6 点 NX7s-20xxR, 16 点 NX7s-20xxR, 8 点 绝缘方法 继电器绝缘 额定输入电压 250V AC, 30V DC 负载电压范围 85 至 264V DC, 10 至 30V DC 最大负载电流...
  • Page 52 晶体管输出 NX7-28xxT NX7s-10xxT NX7-48xxT 目录号 NX7s-14xxT NX7s-40xxT NX7s-20xxT NX7s-48xxT NX7s-28xxT NX7-28xxT, 12 点 NX7s-10xxT, 4 点 NX7-28xxT, 20 点 输出点数 NX7s-14xxT, 6 点 NX7s-20xxT, 16 点 NX7s-20xxT, 8 点 绝缘方法 光电耦合器 额定负载电压 12 至 24V DC 负载电压范围 10 至 30V DC 极性...
  • Page 53 COM1 DIP 开关 COM1 (9 针母型 D-Sub) NX7 控制器) (仅适用于 COM2 (8 针母型 RJ45) 通信状态 LED (通信期间闪烁) RS-232C/RS-485 端接 选择器开关 电阻设置开关 COM1:RS-232C 或 RS-485, 9 针 D-Sub DIP 开关 • NX7s 控制器只在 COM1 上支持 RS-232C。 • 接口 COM2:RS-232C 或 RS-485, 8 针模块化端子...
  • Page 54 2 (COM2) 1 (COM1) (8 针母型 RJ45) (9 针母型 D-Sub) 无 信号 485+ 485- 485+ 485- 保留 485- 信号接地 485+ 1 号与 3 号端子,以及 2 与 4 号端子分别在内 232C/RXD 部相连。 232C/TXD 使用 NX_CBLCPU02 或 NX_CBLCPU05 电缆连接个人计算机 的串行端口与 COM1 端口。有关接线的详细信息,请参见 NX7 控制器用户手册。...
  • Page 56 OE M Controls Trademarks not belonging to OE M Controls are www.oemax.com property of their respective companies. Publication OEMax-NX7-IN001C-MU-P - August 2005 Supersedes Publication NX7-IN001B-MU-P - June 2005 Copyright ® 2005 OE M Controls. All rights reserved. Printed in Korea.