9. Storage
The separate components as filter unit and accessories should be stored in original packaging. You have to observe during
the storage that the components will not be damaged by any items laid on to of them. The storage place has to be dustfree
andprotected against moisture. The storage temperature should not undergo – 10 °C or exceed + 50 °C constantly.
10. Operation Scheme
Magnetic valve
Secure valve
Compressed air
connection
Drain valve for condensate
Clean air side
11. Measurements in case of emergency
During a fire inside the filter unit resp. at its capturing devices you have to follow the following steps:
• Switch off the filter unit at the motor protection switch, if possible.
• Disconnect the filter unit from the power supply by taking off the CEE plug.
• Extinguish the fire with a standard fire extinguisher.
• If necessary contact the local fire brigade to extinguish the fire.
Keep in mind: Do not open the maintenance door in case of any fire. Danger of an explosive flame.
Polluted air side
Silencer
Filter cartridge with
rotating nozzle
Maintenance door
Dust collection container
Impeller wheel
Motor
Motor protection
switch