5.2 Drain of condensate out of the compressed air vessel
Condensate will be collected inside the compressed air vessel. This condensate should be drained during emptying of the dust collection
container. The drain valve is located on the back side of the filter unit. You can put a suitable container below the drain valve and open the
valve. Close the valve after all moisture has been drained and only air is puring out of the valve.
6. Technical Specification
Capacity:
Max. pressure:
Effective filter surface:
Power supply:
Motor performance:
Amperage:
Operation period:
Voltage:
Dimensions (W x D x H):
Weight:
Allowed surrounding temperature:
Noise level at a distance of 1 m
at maximum air volume
7. Spare parts list
Item
Description
1
KemTex
ePTFE-Membran-Filterpatrone
®
(Der Einbau darf nur durch den KEMPER - Service erfolgen)
8. Inspection
The inspection of the filter unit has to be undertaken according to TRGS 560 chapter 5, paragraph 9. You have to record the results of the
inspections in an inspect and test log book. This log book has to be handed out to the inspection authority if this is required.
Daily inspections
Type of inspection
• heck the filling level of the dust extraction container.
• Drain the condensate from the compressed air vessel.
• Check if the connection cable and the CEE plug are not
damaged.
• Check the sense of rotation of the fan if the position of
the unit has been changed.
• Check if the filter material of the filter cartridge is not
damaged.
The user does not have to carry out further inspections. The annual main service or any repairs have to be undertaken by KEMPER service
engineers. Please have a look at the test badge on the unit for getting the next service date. Maintenance work may only be undertaken in a
well air circulated and suitable place to ensure that no people will be affected by any released dust. The engineer should wear protection
equipment as protective gloves, disposal gloves etc. to avoid any contact with hazardous substances. The working station has to be cleaned
after carrying out the maintenance work.
4
1.000 m³/h
2.900 Pa
10 m²
see type plate
1,5 kW
see type plate
100 %
24 V
655 x 655 x 1.460 mm
135 kg
- 10 °C up to + 35 °C
69 dB (A) measured on an open air
test side according to DIN EN ISO 3744
• See chapter „Emptying of the dust collection container".
• See chapter „Drain of condensate from
the compressed air vessel.
• Visual inspection, it might be necessary to get the connection
cable or the CEE plug replaced by an authorized electrician.
• See „Placing into operation".
• Check at the blow out grid on the back side of the filter unit if smoke is
released or dust is layered on the grid during operation of the unit.
This might be an indication of a filter damage. Particles will only be held
back insufficient. Please do not use the filter unit in this case as the
polluted air can get into the working environment of the user and affect
the health of people near the machine. Please contact KEMPER service
department and ask for a service and repair of the filter unit.
Part No.
109 0300
Troubleshooting / Measurements
Need help?
Do you have a question about the Filter-Cell XL and is the answer not in the manual?