380 - 415
380 - 415
220 - 240
10.2 Cable replacement
Should the supply cable need replacing,
remove the back guard by unscrewing the
screws to gain access to the terminal.
Make sure that the cables (for the oven or any
hob) follow the best route in order to avoid any
contact with the oven.
WARNING: The tightening torque of the screws of the terminal supply wires
must be 1.5 - 2 Nm.
92
Instructions for the installer
V
3N~
V
2N~
V
1N~
five-core
5 x 1,5 mm²
four-core
4 x 2,5 mm²
three-core
3 x 4 mm²
H05V2V2-F
H05V2V2-F
H05V2V2-F