• 220-240 V 3~
4 x 1.5 mm² four-core cable.
• 380-415 V 3N~
5 x 1.5 mm² five-core cable.
The values indicated above refer
to the cross-section of the internal
conductor.
The aforementioned power cables
are sized taking into account the
coincidence factor (in compliance
with standard EN 60335-2-6).
Fixed connection
Fit the power line with an all-pole
disconnection switch, with a clearance
between its contacts that allows the
complete disconnection as per the
overvoltage category III, in compliance
with the installation regulations.
50
Installation

5.5 Instructions for the installer

• The plug must be accessible after
installation. Do not bend or trap the
power cable.
• The appliance must be installed
according to the installation diagrams.
• Do not try to unscrew or force the
threaded elbow of the fitting. You may
damage this part of the appliance, which
may void the manufacturer's warranty.
• Use soap and water to check for gas
leaks on all connections. DO NOT use
naked flames when looking for leaks.
• Turn on all the burners separately and at
then all together to make sure that the
gas valve, burner and ignition are
working properly.
• Turn the burner knobs to the minimum
position and check that the flame is
stable for each individual burner and all
the burners together.
• If the appliance does not work correctly
after having carried out all the checks,
contact your local Authorised Service
Centre.
• Once the appliance has been installed,
please explain to the user how to use it
correctly.