8.TEST MODE
to supply water for 7 seconds to the heating water level. Heating operation will
begin when the water level is detected up to the "heating water level", and will
end after the water temperature reaches 60° or the heating time reaches 15
seconds; the heater will not be turned on if the water level is detected below the
"Heating water level", and wait for 15 seconds. The drum starts to tumble during
the heating process at a speed of 55rpm, 5 seconds in clockwise direction, stop
for 5 seconds, and 5 seconds in anti-clockwise direction. Turn on the Main_valve
and Pre_valve together to supply water for 5 seconds. After all of the above
processes are completed, the program will enter in C3;
8.1.5 The program enters in C3. The pump starts to drain away water to the
"Empty-drum water level". The water shall be drained within a limited time of
6min. If the water is discharged down to the "Empty-drum water level"
successfully, the program will enter in C4, and if the water is not discharged
down to the "Empty-drum water level" within 6min, then an alarm code of F03
will display;
8.1.6 The program enters in C4. The pump continues to drain away water, while
the drum tumbles at a speed of 95rpm for 10 seconds. Then the drum starts to
tumble at an accelerating speed of 60 rpm/s. The target speed is the maximum
speed(1000rpm), and the whole process consumes 200 seconds in total. After
all of the above processes are completed, the drum will stall. If there is not any
key input for 30 seconds, it will exit the "Self-inspection mode".

8.2 SPECIAL FUNCTION MODE

1) Turn the knob to "Spin" through "Off" to start up the machine, select the "Spin"