10.COMPONENT TESTING INFORMATION

10.3 MOTOR

Wiring
diagram
Function
Test points
and result
Circuit in the PCB / Wiring Diagram
The SCR controls to impose different break-over voltage onto the stator to control
the size of rotation speed, and when the rotation speed increases up to a null
value (600rpm, the complete machine), switch off the high-speed tap via K1 to
reach 1400rpm, the maximum rotation machine of complete machine; adjust the
rotation direction of rotator via K2 and K3 so as to make the complete machine to
revolve clockwise and anti-clockwise.
Test points
M10-M7
M7-M6
M9-M8
M1-M2
Result
1.900±7%Ω
1.100±7%Ω
2.48±7%Ω
68.8±7%Ω