Installation Instructions
422 Cam Action Door Closer
Push and Pull Side, Door and Frame Mounted
Non-Hold Open and Hold Open Applications
CAUTION
An incorrectly installed or improperly adjusted door closer can cause
property damage or personal injury. These instructions should be
followed to avoid the possibility of misapplication or misadjustment.
Hold open units are not permitted to be installed in fire door assemblies.
NOTES:
‒ For special applications a separate door and frame preparation tem-
plate is packed with these instructions.
‒ Use this instruction sheet for installation sequence and closer adjust-
ments only.
‒ Use of an auxiliary door stop is always recommended.
Pull Side Door Mount
Right Hand Door - RH
Left Hand Reverse - LHR
Pull Side Frame Mount
422D Back Plate required if frame face is less than 3" (76mm).
Right Hand Door - RH
Left Hand Reverse - LHR
Included Components
Closer Body
Power
Adjustment
Shaft
Full Cover
with Insert
1-800-727-5477 • www.sargentlock.com
Copyright © 2023, 2024, SARGENT Manufacturing Company. All rights reserved. Reproduction in whole or in part without the express
written permission of SARGENT Manufacturing Company is prohibited. Patent pending and/or patent www.assaabloydss.com/patents.
A8386 03/24 Rev 3
63-8386-6000-999
Standard Applications
Left Hand Door - LH
Right Hand Reverse - RHR
Optional Applications
Left Hand Door - LH
Right Hand Reverse - RHR
Closer Body
Screw Pack
Spring Stop
Slide Track
Arm
Slide Track
Assembly
Approved 2024-03-15
READ AND FOLLOW ALL INSTRUCTIONS.
SAVE THESE INSTRUCTIONS.
The closing force for Series 422 door closers is adjustable
from a size 1 to a size 6, as outlined in ANSI Standard A156.4.
When these series of door closers are installed and adjusted
to conform to ADA reduced opening force requirements
(5 lbs max.) for interior doors, they may not have adequate
closing force to reliably close and latch the door. Power
adjustments charted on page 2 are recommended
where possible, to ensure proper door control.
Push Side Frame Mount
Right Hand Door - RH
Left Hand Reverse - LHR
Push Side Door Mount
63-0853 Angle Bracket required.
Left Hand Door - LH
Right Hand Reverse - RHR
Hold Open Device
(Standard with Hold
Open model)
Spline Shaft
Screw Pack
Track Mounting
Screw Pack
Left Hand Door - LH
Right Hand Reverse - RHR
Right Hand Door - RH
Left Hand Reverse - LHR
Optional Components
60-0853
Slide Track
Angle Bracket
(required for push
side door mounted
applications)
422D Back Plate
(required for pull side frame
mounted applications)

Advertisement

loading
Need help?

Need help?

Do you have a question about the SARGENT 422 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Assa Abloy SARGENT 422

  • Page 1 Installation Instructions 422 Cam Action Door Closer Push and Pull Side, Door and Frame Mounted Non-Hold Open and Hold Open Applications CAUTION READ AND FOLLOW ALL INSTRUCTIONS. An incorrectly installed or improperly adjusted door closer can cause SAVE THESE INSTRUCTIONS. property damage or personal injury.
  • Page 2: Supplied Hardware

    Cam Action Door Closer Installation Instructions Supplied Hardware Fasteners Door or Frame Drill Sizes Closer: 3/16" (4.8mm) pilot hole required 1/4” Self-Drilling Screw (Closer Body Only) Aluminum Metal or Wood Track: 3/32 “ (2.4mm) pilot hole required #12-14 Self-Drilling Screw (Track Only) Standard Closer: Drill #7 (.201 dia.
  • Page 3: Installation Sequence

    Cam Action Door Closer Installation Instructions Pull Side Door Mount Installation 1-5/16 19-1/8 (486) (102) (33) (2) #12-24 Tapped Holes for Machine Screws *1-1/2 or 3/32" Pilot Holes for Self Drilling Screws (39) 1-1/16 (27) Frame Rabbet (51) Top of Door 3-1/2 3-5/16 (89)
  • Page 4 Cam Action Door Closer Installation Instructions Push Side Frame Mount Installation (4) 1/4-20 Tapped Holes for Machine Screws 3-13/16 11-1/8 (283) or 3/16" Pilot Holes for Self Drilling Screws Min. Ceiling Height 2-5/16 (96) for Closer Body 2-15/16 (74) (58) 1-5/8 2-1/8 (41)
  • Page 5 Cam Action Door Closer Installation Instructions Pull Side Frame Mount Installation Installed on a frame face greater than 3" (76mm) (4) 1/4-20 Tapped Holes for Machine Screws 3-13/16 11-1/8 (283) or 3/16" Pilot Holes for Self Drilling Screws 2-5/16 (98) 4 (102) Holes for Closer Body (58)
  • Page 6 Cam Action Door Closer Installation Instructions Push Side Door Mount Installation 1-11/16 63-0853 Angle 19-15/16 (43) Bracket (506) 1-3/16 (51) Frame Rabbet (30) 2-7/8 5-7/8 Frame Stop (73) (149) 63-0853 Angle 1-11/16 Bracket (43) NOTES: 4-1/8 3-1/2 For Optional (25) y Right hand door shown (105) (89)
  • Page 7 Cam Action Door Closer Installation Instructions Adjustments Arm Attachment to Track Slider: Figure 2 - Closing Power Control Power Adjustment Shaft Move arm in position under slider stud. Insert 5mm hex wrench Increase use 5/8" socket through threaded hole in the arm and into hex on stud. Rotate or adjustable wrench counter-clockwise until tightened.
  • Page 8 Setup for Inclusive Restroom/Telephone Booth Function 1. Open the door to the desired "propped" position. 2. With the arm parallel to the door, insert the spline shaft into the closer body. 3. Secure the arm to the slider stud using the 5mm hex wrench.