Installation Instructions
422 Cam Action Door Closer
Push and Pull Side, Door and Frame Mounted
Non-Hold Open and Hold Open Applications
CAUTION
An incorrectly installed or improperly adjusted door closer can cause
property damage or personal injury. These instructions should be
followed to avoid the possibility of misapplication or misadjustment.
Hold open units are not permitted to be installed in fire door assemblies.
NOTES:
‒ For special applications a separate door and frame preparation tem-
plate is packed with these instructions.
‒ Use this instruction sheet for installation sequence and closer adjust-
ments only.
‒ Use of an auxiliary door stop is always recommended.
Pull Side Door Mount
Right Hand Door - RH
Left Hand Reverse - LHR
Pull Side Frame Mount
422D Back Plate required if frame face is less than 3" (76mm).
Right Hand Door - RH
Left Hand Reverse - LHR
Included Components
Closer Body
Power
Adjustment
Shaft
Full Cover
with Insert
1-800-727-5477 • www.sargentlock.com
Copyright © 2023, 2024, SARGENT Manufacturing Company. All rights reserved. Reproduction in whole or in part without the express
written permission of SARGENT Manufacturing Company is prohibited. Patent pending and/or patent www.assaabloydss.com/patents.
A8386 03/24 Rev 3
63-8386-6000-999
Standard Applications
Left Hand Door - LH
Right Hand Reverse - RHR
Optional Applications
Left Hand Door - LH
Right Hand Reverse - RHR
Closer Body
Screw Pack
Spring Stop
Slide Track
Arm
Slide Track
Assembly
Approved 2024-03-15
READ AND FOLLOW ALL INSTRUCTIONS.
SAVE THESE INSTRUCTIONS.
The closing force for Series 422 door closers is adjustable
from a size 1 to a size 6, as outlined in ANSI Standard A156.4.
When these series of door closers are installed and adjusted
to conform to ADA reduced opening force requirements
(5 lbs max.) for interior doors, they may not have adequate
closing force to reliably close and latch the door. Power
adjustments charted on page 2 are recommended
where possible, to ensure proper door control.
Push Side Frame Mount
Right Hand Door - RH
Left Hand Reverse - LHR
Push Side Door Mount
63-0853 Angle Bracket required.
Left Hand Door - LH
Right Hand Reverse - RHR
Hold Open Device
(Standard with Hold
Open model)
Spline Shaft
Screw Pack
Track Mounting
Screw Pack
Left Hand Door - LH
Right Hand Reverse - RHR
Right Hand Door - RH
Left Hand Reverse - LHR
Optional Components
60-0853
Slide Track
Angle Bracket
(required for push
side door mounted
applications)
422D Back Plate
(required for pull side frame
mounted applications)
Need help?
Do you have a question about the SARGENT 422 and is the answer not in the manual?
Questions and answers