5 ADAPTING TO DIFFERENT TYPES OF GAS

Before performing any cleaning or maintenance work, disconnect the appliance from
the electrical socket.
The hob has been adjusted for natural gas at a pressure of 1.0 kPa. For functioning
with other types of gas the nozzles must be replaced and the primary air adjusted.
To replace the nozzles and regulate the burners, you have to remove the top as
described in the following paragraph.
5.1 Removing the hob
Remove all of the burner components by following the numerical sequence shown in
the figure:
• Remove all of the knobs (1) by pulling them upward;
• Remove the grids (2), lifting up one of the two horizontal spokes;
• Remove the burner caps (3) and flame crowns (4);
• With wrench A (supplied), open the bayonet clamps on the burner rings by
levering on guides B;
• Insert a wrench or a screw driver in one of the holes of the tool to simplify
removal;
• After having removed all of the above-described components, raise the surface to
access the burners and gas taps.