Download Print this page

WE-EF FLA441 LED Installation And Maintenance Instructions Manual

Wall luminaire surface mounted and street and area lighting luminaire

Advertisement

Quick Links

Do not open during installation
This product is factory-sealed.
Refer to the instructions contained in this
document for details.
Surge Protection
This product features built-in surge protection circuitry in compliance
with applicable standards.
For comprehensive protection of a luminaire installation against lightning
and electrical surges, it is essential to cover mains supply and data input
lines at the distribution board level, by using respective primary (Type 1)
and secondary (Type 2) surge arrestors in compliance with EN61643-11/
IEC61643-1.
Warning
Ensure that all required surge protection measures are in place and
activated prior to luminaire installation. Also, disconnect luminaires
before operating high-power devices such as, for example, electrical
arc welders.
WE-EF LEUCHTEN
Installation and Maintenance
Wall Luminaire Surface Mounted and
Street and Area Lighting Luminaire
Instructions
FLA441 LED
FLA461 LED

Advertisement

loading

Summary of Contents for WE-EF FLA441 LED

  • Page 1 WE-EF LEUCHTEN Installation and Maintenance Instructions Wall Luminaire Surface Mounted and Street and Area Lighting Luminaire FLA441 LED FLA461 LED Do not open during installation Surge Protection This product is factory-sealed. This product features built-in surge protection circuitry in compliance Refer to the instructions contained in this with applicable standards.
  • Page 2 Wall Luminaire Surface Mounted and Street and Area Lighting Luminaire FLA441 ø 11 FLA461 ø 11...
  • Page 3: Maintenance

    Light Source Maintenance Apart from cleaning the product’s exterior surfaces, no special maintenance work is required. Do not use high-pressure cleaners. In case of component failure due to abnormal circumstances or at end of life, replacement must be carried Warning: Do not open luminaire while mains supply is switched on.
  • Page 4: Installation Procedure

    (L = Phase, N = Neutral, = Earthing) b) WE-EF Control Basic (L = Phase, N = Neutral, Attention: The housing H containing the LED light = Earthing, Ls = Switching Phase) source is factory-sealed and does not need to be or WE-EF Control Dynamic opened during installation.
  • Page 5 Mounting Accessories D/D1 310-9110 310-9109 ø 12 Planted root – Galvanised steel. 300-9100 300-0824 landscaped areas. 310-9134 310-9135 – Aluminium/wood. 310-9136 – Aluminium/wood. Stepped spigot 310-9137 (ø 102 x 80) + (ø76 x76) ø 140 EB1/EB2 Stepped spigot (ø 102 x 80) + (ø76 x76) ø...
  • Page 6 Fig. I. Feed mains supply cable through cable gland...
  • Page 7 WE-EF LEUCHTEN WE-EF LIGHTING Germany Thailand Fax +66 2 175 2174 info.germany@we-ef.com info.asiapacific@we-ef.com WE-EF LUMIERE WE-EF LIGHTING France Australia Tel +33 4 74 99 14 44 info.france@we-ef.com info.australia@we-ef.com WE-EF SWITZERLAND WE-EF LIGHTING United States of America Tel +41 22 752 49 94 Fax +41 22 752 49 74 info.usa@we-ef.com...
  • Page 8 WE-EF LEUCHTEN Installation and Maintenance Instructions Planted Root ESV4 ESV6 ESZ4...
  • Page 9 Planted Root ESV4 300-0461 ESV4 300-0464 Suitability Suitability 1. KTX234 1. CFY259 2. KTY234 2. GRY234 3. ZFY230 3. RRY324 4. GRY224 4. RRZ324 5. Short post 5. XRY324 6. XRZ324 ESV4 300-0586 ESV4 300-0459 Suitability Suitability 1. XRY334 1. QSI254 2.
  • Page 10 Planted Root ESV6 300-0824 ESV6 300-0457 Suitability Suitability 1. AML-C 1. LTM440 2. FLA461 2. LTM444 3. AMW-C 4. AMF-C 5. AMF-S 6. AML-C ESZ4 300-9115 ESZ4 300-9090 Suitability Suitability 1. PSY414/424 1. MRY224...
  • Page 11: Installation Instruction

    Installation Instruction 1) Note: It is the responsibility to installer to 2) Please note, ESV4 and ESV6 must be ensure the suitability of the ESV/ESZ planted root for any local or national structural require- In both instances conduit entry can be rotated ments for installation, and that planted root is to match cable routing.
  • Page 12 5) For ESZ4 please orientate planted root as shown (base plate is parallel to the pathway). cal connections/conduit. For this installation, use 30 mm long M12 bolts for PSY planted root and 35 mm long M10 bolts for MRY planted root. M12 x 30 M10 x 35 7) Place the ESV/ESZ in the form work for con-...
  • Page 13 9) Pour concrete to desired level depending on requirement of concrete, paver or soil. Ensure (as per luminaire instructions) onto mounting level. Concrete Paver Soil...
  • Page 14 WE-EF LIGHTING Switzerland United States of America Tel +41 22 752 49 94 Tel +1 724 742 0030 Fax +41 22 752 49 74 Fax +1 724 742 0035 info.switzerland@we-ef.com info.usa@we-ef.com TO9257W0124 © WE-EF 2024 Technical specifications are subject to change.

This manual is also suitable for:

Fla461 led