Installation of the appliance

Distances

The appliance must be installed by a qualified
technician and according to the standards in
force. Depending on the type of installation,
this appliance belongs to class 2, subclass1
(Fig. A - Fig. B) or class 1 (Fig. C).
It may be installed next to walls, one of
which must be higher than the appliance, at
a minimum distance of 50 mm from the side
of the appliance, as shown in figures A and C
relative to the installation classes.
Caution! Any wall units must be
at a distance of at least 750 mm
above the appliance. This distance
can be reduced to 650 mm if a
ventilation hood is installed.

Electrical connection

Caution! If the appliance is
connected to the supply by means
of a fixed connection, install a
multipolar cut-out device on the
line, with contact opening
distance equal to or greater than
3 mm, located near the appliance
and in an easily reachable
position.
Caution! Check that the voltage
and dimensioning of the supply
line correspond to the
characteristics shown on the
plate fixed to the rear protective
cover of the appliance.
This plate must never be
removed.
The connection terminals are located at the
rear of the appliance. For electrical
connections see following diagram.