11.3 Separate the motor from the pump housing

1. Attach the motor top cover (164) with the lifting handle to the stator housing. This is necessary to provide a safe lifting point!
2. Undo and remove the six M16 screws (67), together with the washers (67B).
3. Attach the lifting chain to the lifting handle and lift the motor up.
4. Remove the O-ring (39B).
5. Move the lifted motor away and carefully place it horizontally on the ground. Secure it in a way to prevent any rolling or sideways
movement.
67
164
62
164
67
67B
39B
39