6.7 Adjusting the regeneration frequency (models with softener only)
6.8 Memorisation procedure
To access the programming menu, proceed as follows:
1) switch the appliance off by pressing the On Off
2) Hold down the
3) Use the
key to modify the parameter; H0,H1,H2,H3,H4,H5 and H0 will appear on the display
in cyclic sequence
4) Press the On Off key to confirm the change and quit programming mode.
With values over 60°dF an external water treatment device must be used and the
regeneration frequency must be set at H00
6.9 Table of parameters
This table shows the relationship between the intake water hardness and the quantity the resins are
able to treat; regeneration is required once the appliance has preformed the set number of cycles.
Regeneration cycle duration: 12 minutes.
Hardness (dH German degrees)
Regeneration off
8,5
11
17
22,5
28
33,5
7 MALFUNCTIONS SHOWN ON THE DISPLAY (FOR
The dishwasher is able to identify a number of malfunctions and show them on the display.
If the problem persists after the dishwasher has been switched off and back on, proceed as described
below:
E.1
Boiler temperature probe malfunction
‐ CWG410 ‐
and
keys simultaneously for 6 seconds; H0 appears on the display
Hardness (dF French
degrees)
Regeneration off
15
20
30
40
50
60
THE TECHNICIAN)
key
Setting level
H00
H01
H02
H03 default
H04
H05
H06
Boiler temperature probe disconnected or not
working
18
Resin duration in
wash cycles
Function off
94 wash cycles
83 wash cycles
53 wash cycles
33 wash cycles
27 wash cycles
20 wash cycles