Electrical Connection - Daikin FDM20JEVLK Installation Manual

Table of Contents

Advertisement

IMPORTANT:
*
These values are for information only, they should be checked and selected to comply with the local and/or national
codes and regulations. They are also subjected to the type of installation and size of conductors.
** The appropriate voltage range should be checked with data label on the unit.
FDM20JEVLK - RD20JEVLK
FDM25JEVLK - RD25JEVLK
COMP
L
Indoor unit
Terminal Block
N
N
Model
Voltage range**
Power supply cable size*
Number of conductors
Interconnection cable size*
Number of conductors
Recommended time delay fuse*
FDM30JEVLK - RD30JEVLK
COMP
L
Indoor unit
N
Terminal Block
N
Model
Voltage range**
Power supply cable size*
Number of conductors
Interconnection cable size*
Number of conductors
Recommended time delay fuse*

ELECTRICAL CONNECTION

Interconnection
cable
Power Supply
Cable
Indoor
Outdoor
Indoor
Outdoor
mm
2
mm
2
A
Interconnection cable
Power Supply Cable
Indoor
Outdoor
Indoor
Outdoor
mm
2
mm
2
A
1-13
COMP
L1
Outdoor unit
Terminal Block
N1
L
N
!
FDM20JEVLK
RD20JEVLK
220V/1Ph/60Hz+!
220V/1Ph/60Hz+!
2.5
3
1.0
4
20
COMP
L
Outdoor unit
N
Terminal Block
L
!
N
FDM30JEVLK
RD30JEVLK
220V/1Ph/60Hz+!
220V/1Ph/60Hz+!
4.0
3
2.5
4
30
There must be an all pole
disconnection in the supply
mains with a contact separation
of at least 3mm.
FDM25JEVLK
RD25JEVLK
2.5
3
1.0
4
25
There must be an all pole
disconnection in the supply
mains with a contact separation
of at least 3mm.