3. Non-standard paint options may cause risk from electrostatic
discharge. Avoid installations that could cause electrostatic
build-up on painted surfaces and only clean the painted
surfaces with a damp cloth. If paint is ordered through
a special option code, contact the manufacturer for more
information.
9.8.2  I2 Brazil Intrinsic Safety
Certificate
Standards
Markings
Table 9-8: Input parameters 
Voltage U
Current I
Power P
Capacitance C
Inductance L
Special Conditions for Safe Use (X):
1. If the equipment is fitted with an optional 90 V transient
suppressor, it is not capable of withstanding the 500 V
insulation test required by ABNT NBR IRC 60079-11. This must
be taken into account when installing the equipment.
2. The enclosure may be made of aluminum alloy and given
protective polyurethane paint finish; however, care must be
taken to protect it from impact or abrasion if equipment
requires EPL Ga.
9.8.3  IB Brazil FISCO
Certificate
Standards
Markings
Quick Start Guide
UL-BR 13.0584X
ABNT NBR IEC60079-0: 2013, ABNT NBR IEC60079-11:
2013
HART
: Ex ia IIC T5/T4 Ga, T5 (–60 °C ≤ T
®
(–60 °C ≤ T
≤ +70 °C)
a
Fieldbus/PROFIBUS
+60 °C)
HART
30 V
i
200 mA
i
0.9 W
i
0.012 µF
i
0 mH
i
UL-BR 13.0584X
ABNT NBR IEC60079-0: 2013, ABNT NBR IEC60079-11:
2013
Ex ia IIC T4 Ga (-60 °C ≤ T
: Ex ia IIC T4 Ga (–60 °C ≤ T
®
Fieldbus/PROFIBUS
30 V
300 mA
1.3 W
0 µF
0 mH
≤ +60 °C)
a
Quick Start Guide
≤ +40 °C), T4
a
a
41