Minimum Fireplace And Hearth Dimensions; Hearth Requirements; Ember Protection - Pacific energy SUMMIT INSERT LE Installation And Operating Instructions Manual

Table of Contents

Advertisement

Minimum Fireplace and Hearth Dimensions

8
200mm
Figure 3: Fireplace opening dimensions.

Hearth requirements:

The fireplace's non-combustible hearth must extend 16" in front and 8" beyond each side of the existing
fireplace opening and be raised 3" above any adjacent combustible floor. See Figure 3.
A non-combustible hearth that extends a minimum 24" / 610mm (in Canada) or 22" (in the U.S.) in front of
the fireplace opening can be flush to an adjacent combustible floor (See Figure 5).

Ember Protection:

Combustible flooring in front of the fireplace insert must be protected from hot embers by non-combustible
material extending 16" (USA) and 18" (CANADA) from the firing side (Door Glass) and 8" to the sides of the
unit (Figure 4).
Consult CAN/CSA-B365 Installation Code for Solid-Fuel-Burning appliances and equipment in Canada, and
N.F.P.A. 211 Standard for chimneys, fireplaces, vents and Solid-Fuel-Burning appliances in USA.
100000089
711mm
"
22
1/2
572mm
"
"
28
1/4
"
26
1/4
660mm
"
19
482mm
406mm
"
16
"
3
76mm
SUMMIT INSERT LE 230424-32