Supervisor Level (Programming Mode); Requirements For Accessing Supervisor Level; Accessing Supervisor Level; Overview Of Supervisor Level - Miele PDR 514 Operating And Installation Instructions

Commercial tumble dryers
Table of Contents

Advertisement

Supervisor level (programming mode)

Requirements for accessing supervisor level

- The appliance is switched on.
- The appliance door is open.

Accessing supervisor level

Touch and hold the Start/Stop sensor control and close the door.
The Start/Stop sensor control flashes rapidly for 2 seconds.
Continue touching the Start/Stop sensor control for at least 4 seconds.
The Start/Stop sensor control will light up constantly. This indicates that you have success-
fully accessed the supervisor level programming mode.
Release the Start/Stop sensor control.
If the illuminated Start/Stop sensor control is not released again within 6 seconds, the ap-
pliance will detect an accessing error or a door jam.
The maximum time for the access attempt is 10 seconds. The attempt will then be can-
celled automatically.

Overview of supervisor level

If the pre-set values in the supervisor level are changed, the tumble dryer's energy require-
ments may change.
Pro-
Designation
gramme

Drying level Cottons

Drying level Minimum iron
Cottons & Timed operation internal/ex-
ternal 1

Heater bank temperature

Cottons & Timed operation internal/ex-
ternal 1
Process air temperature

Cottons & Timed operation internal/ex-
ternal 1
Drum drive running time in primary dir-
ection

Cottons & Timed operation internal/ex-
ternal 1
Drum drive running time in reverse dir-
ection
26
Possible set
Standard
value
setting
















–

–

–

–

Explanation
 = Damper 3
 = Damper 2
 = Damper 1
 = Standard
 = Drier 1
 = Drier 2
 = Drier 3
 = Damper 3
 = Damper 2
 = Damper 1
 = Standard
 = Drier 1
 = Drier 2
 = Drier 3
See "Heater bank temperature" table
See "Process air temperature" table
See table "Reversing cycle"
See table "Reversing cycle"

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pdr 518Pdr 522Pdr 528Pdr 544

Table of Contents