Supervisor level (programming mode)
Requirements for accessing supervisor level
- The appliance is switched on.
- The appliance door is open.
Accessing supervisor level
Touch and hold the Start/Stop sensor control and close the door.
The Start/Stop sensor control flashes rapidly for 2 seconds.
Continue touching the Start/Stop sensor control for at least 4 seconds.
The Start/Stop sensor control will light up constantly. This indicates that you have success-
fully accessed the supervisor level programming mode.
Release the Start/Stop sensor control.
If the illuminated Start/Stop sensor control is not released again within 6 seconds, the ap-
pliance will detect an accessing error or a door jam.
The maximum time for the access attempt is 10 seconds. The attempt will then be can-
celled automatically.
Overview of supervisor level
If the pre-set values in the supervisor level are changed, the tumble dryer's energy require-
ments may change.
Pro-
Designation
gramme
Drying level Cottons
Drying level Minimum iron
Cottons & Timed operation internal/ex-
ternal 1
Heater bank temperature
Cottons & Timed operation internal/ex-
ternal 1
Process air temperature
Cottons & Timed operation internal/ex-
ternal 1
Drum drive running time in primary dir-
ection
Cottons & Timed operation internal/ex-
ternal 1
Drum drive running time in reverse dir-
ection
26
Possible set
Standard
value
setting
–
–
–
–
Explanation
= Damper 3
= Damper 2
= Damper 1
= Standard
= Drier 1
= Drier 2
= Drier 3
= Damper 3
= Damper 2
= Damper 1
= Standard
= Drier 1
= Drier 2
= Drier 3
See "Heater bank temperature" table
See "Process air temperature" table
See table "Reversing cycle"
See table "Reversing cycle"