Problem solving guide
Problem
Condensation is forming in
the drum.
38
Cause and remedy
Check and clean all components in the vent ducting (e.g.
wall pipe, external grille, bends, elbows, etc.).
The flow of air is insufficient (e.g. because it is installed in a
small room).
When drying, open a door or window to ensure sufficient
ventilation.
The laundry has not been spun sufficiently.
Make sure that your laundry is thoroughly spun at the ap-
propriate spin speed in the washing machine.
The tumble dryer has been overloaded.
Do not exceed the maximum load size for the drying pro-
gramme selected.
Metallic components, e.g. zips, have prevented the tumble
dryer from registering the correct laundry moisture level.
Open any zips next time.
If the problem occurs again, dry garments with long zips
using the hot air drying programme.
The tumble dryer is installed on a shared exhaust air duct.
The tumble dryer must always be installed with a non-re-
turn flap when using a combined line.
Check the non-return flap for possible defects on a regular
basis and replace the flap if necessary.