PRO 800-900 G-PL SUMMARY 1. INSTALLATION......................3 1.1. G ....................... 3 ENERAL POINTS 1.2. H ......................... 3 ANDLING 1.3. I ......................3 NSTALLATION 1.4. D ......................4 ATA PLATE 1.5. F ....................4 IXING THE LOW FLUE 2. GAS CONNECTIONS ..................... 5 2.1.
PRO 800-900 G-PL INSTALLATION General points 1.1. Installation must be undertaken in compliance with the following instructions and with local codes and bylaws. Ensure you have a suitable and sufficient risk assessment in place. This appliance is of A-type and shall not be connected to a flue gas pipe. The user’s manual must be given to the user after installation.
PRO 800-900 G-PL Data plate 1.4. Each appliance has is own data plate. Transfer all the information written on the data plate to the part of the user’s manual reserved for it. This will ease the communication between you and your client for better service. Data plate: Appliance with oven: data plate in In cupboard / open base...
PRO 800-900 G-PL GAS CONNECTIONS Warnings Fixed appliance: Connect the appliance to the gas mains using 1/2“ NPT pipe and connections. Install a suitable shutoff valve (or valve + pressure regulator) in the supply line, allowing the unit to be isolated from the rest of the cooking range.
PRO 800-900 G-PL Connecting the appliance to the gas mains 2.2. Fig.1 Pressure outlet Gas connection Thermostatic tap Appliances with oven - Remove the control knobs, - Remove the control panel (fixed with 2 screws), - Connect the appliance to the gas mains using ½” M tube (fig. 1), Note: The pressure tap is accessible (see §...
PRO 800-900 G-PL Checks after connection 2.3. The water system is well watertight, Supply pressure of the appliance in working state, The colour of the flame (blue), The slow-down position (see § 3.4.), The good working state of the appliance and its safety devices. Checks of pressure supply 2.4.
Page 8
PRO 800-900 G-PL Refractory cement heat retention Small solid top plate shielding Full module unit G-PL - Remove the solid top and refractory cement Air ring heat retention shielding to access the venturi, - Unlock the air ring (3), nut ()/ring, Injector - Change the injector (1) (ring spanner 17mm)
PRO 800-900 G-PL Changing the injectors and adjusting air of the oven pilot light 3.2. Fig. 3 Remove the mild steel base. Unscrew the nut (A) with an open-end spanner 11mm, Change the injector (B); see chart § 3.3. Adjustment of air ring (Fig. 3 (C)); see chart § 3.3. Check the watertightness of the gas pipe and the good working condition of the pilot light.
PRO 800-900 G-PL Gas adjustment charts 3.3. Large solid top plate Gas type Mark Nominal & operating pressure engraved on adjustment calorific the injector d (mm)*2 output (kW)*1 G20: Pn = 20 mbar G 25: Pn = 20 mbar G 25: Pn = 25 mbar G 30: Pn = 29 mbar G 30: Pn = 50 mbar G 31: Pn = 37 mbar...
PRO 800-900 G-PL Adjusting the oven output 3.4. Output adjustment is done in factory (Thermostatic control) Only qualified staff can do the adjustment. It could be necessary to adjust it. Thermostatic tap This operation must be carried out very quickly and before the thermostat responds and the burner turns to the maxi output position.
PRO 800-900 G-PL Adjusting the slow down position 3.5. Knob in slow-down position Fig.3 knob Slow-down screw Symbol Small flame or slow-down position Adjusting the slow-down position of the burner Remove the control knobs, Remove the control panel, (see § 2.2. – gas connections) Refit in place the control knob Switch ON the appliance.
Wiring diagrams # S = standard coupling Electric ignition SE0001/00 Electric hot cupboard GN1/1 SE0005/00 Electric hot cupboard GN2/1 SE0006/00 Thermostatic Tap SE0117/00 A → Coupling possible B→ Please consult Charvet C → Coupling impossible D → No voltage available...
PRO 800-900 G-PL WIRING DIAGRAMS ELECTRIC IGNITION: 1 to 2 BURNERS Oven burner 01 Terminals 02 Push button 03 Ignition transformer 04 Electrode 1 Burner / 1 Transformer mounting A 2 Burners / 1 Transformer mounting B 1 ~ 230V + PE SE0001 / 00...
Page 15
PRO 800-900 G-PL ELECTRIC HOT CUPBOARD GN 1/1 1 ~ 230V + PE P = 1,5 kW SE0005 / 00 NOMENCLATURE: ELECTRIC HOT CUPBOARD GN1/1 (SE0005 / 00) Mark Code Description Quantity 02468A 10 mm² terminal (brand: Viking) 07069A Blue terminal Vicking 03575A Earth terminal (brand: Viking) 01995A Thermostat 505914 Red indicator 230 V...
Page 16
PRO 800-900 G-PL ELECTRIC HOT CUPBOARD GN2/1 3 ~ 400V + PE P = 2,25 kW SE0006 / 00 NOMENCLATURE: ELECTRIC HOT CUPBOARD 800 mm x 600 mm (diagram: SE0006 / 00) Mark Code Description Quantity 02468A 10 mm² terminal (brand : Viking) 03575A Earth terminal (brand: Viking) 01995A Thermostat 505914 Red indicator 400 V...
Page 17
PRO 800-900 G-PL THERMOSTATIC TAP SE0117/00 10.10.06: 1~230V+E NOMENCLATURE: THERMOSTATIC CONTROL (SE0117/00) Mark Code Quantity Description 08426A Thermostat 08425A Solenoid valve 02468A Terminal...
PRO 800-900 G-PL BASIC SPARE PARTS LIST Description / Code Description / Code Photograph Photograph Gas tap Thermostatic control 00311A 08425A Gas injector Gas injector Solid top oven G20/G25 G20/G25 Ø 2.50 Natural Ø 2.50 Natural 00209A 00209A Ø 1.80 Propane Ø...
PRO 800-900 G-PL Tripolar thermostat Oven thermostat Hot cupboard 350°C 30-110° 08426A 01995A Central ring Ring set for the large Small solid top solid top plate plate 05192A 05213A Small solid top Solid top plate plate600 x 422 mm 600 x 841 mm 05165A 02926A MAINTENANCE...
Page 20
GAS SOLID TOP Description PRO 800 SERIES PRO 900 SERIES G1PL/G2PL V01603 V01583 V01535 V01459 B-G1PL/B-G2PL V01605 V01585 V01538 V01462 R-G1PL/R-G2PL V01606 V01586 V01731 V01726 1/2B-G1PL V01928 V01953 1/2R-G1PL V01628 V01736 USER’S INSTRUCTIONS CHARVET F-38850 – CHARAVINES MANUAL: 800-900 EN G-PL Tel.: +33 (0) 476 066 422...
Page 21
PRO 800-900 G-PL SUMMARY 1. INTRODUCTION ......................3 2. PRIOR TO STARTING UP ..................... 3 3. STARTING UP ....................... 4 3.1. S ....................... 4 OLID TOP PLATE 3.2. O ........................4 3.3. E ..................4 LECTRIC HOT CUPBOARD 4. SWITCHING OFF ......................5 5.
PRO 800-900 G-PL INTRODUCTION Our equipment is for professional use only and must be used by qualified staff. The equipment must be installed in compliance with local codes and bylaws. It must be installed in a kitchen equipped with an adequately sized mechanical extraction system. Appliances may be installed side by side or against walls of non combustible material.
PRO 800-900 G-PL STARTING UP General points: Each burner is equipped with a safety thermocouple and a pilot light. Solid top plate 3.1. Take off the central ring. Push and turn the control knob counter-clockwise of desired burner (fig. 1, mark “P”) until the spark symbol.
PRO 800-900 G-PL WARNING: When opening the oven door in “wet” cooking mode, stay clear from the oven as vapours can escape and burn your skin very seriously! Side panels and oven door may be extremely hot after a prolonged or intensive use. Be careful to open the door only with the handle.
PRO 800-900 G-PL Cleaning of the mild steel base, oven shelf and shelf runner 5.4. OVEN GRID MILD STEEL BASE Process: disassembly and reassembly of mild steel base and shelf runners A) Pull out the grid towards you. B) Pull out the mild steel base by using the oblong-shaped hole. C) 1 et 2 : Lift the shelf runner, then pull it out to the left 3: Pull out the shelf runner towards you.
PRO 800-900 G-PL For best results, have your equipment serviced and cleaned on a regular basis by a qualified installer. WARNING: Certain parts of this appliance are protected by the manufacturer, and must not be handled by the installer or the user. IN CASE OF BREAKDOWN UNSATISFACTORY HEATING 6.1.