Charvet PRO 800 Series Installation And Setup Instructions

Gas cooking ranges
Hide thumbs Also See for PRO 800 Series:

Advertisement

Quick Links

Installation and Set Up Instructions
Description
G4FN
B-G4FN
R-G4FN
B-G2FN
R-G2FN
CHARVET
F-38850 CHARAVINES
Tel.: (33) 4-76-06-64-22
Fax: (33) 4-76-55-78-75
Email:
info@charvet.fr
For Gas Cooking Ranges
PRO 800
series
V01579
V01581
V01582
V01927
V01626
OPEN BURNERS ON OPEN CUPBOARD
(not contractual photographs)
Installer Instructions : 800/900 UK GFN
French edition: 31.08.06; Update number E
English edition: 17.01.2008; Update number B
Code of notice: F800/900N
PRO 900
series
V01455
V01458
V01725
V01952
V01735

Advertisement

Table of Contents
loading

Summary of Contents for Charvet PRO 800 Series

  • Page 1 V01927 V01952 R-G2FN V01626 V01735 OPEN BURNERS ON OPEN CUPBOARD (not contractual photographs) CHARVET Installer Instructions : 800/900 UK GFN F-38850 CHARAVINES French edition: 31.08.06; Update number E Tel.: (33) 4-76-06-64-22 English edition: 17.01.2008; Update number B Fax: (33) 4-76-55-78-75...
  • Page 2: Table Of Contents

    Installation and Set Up Instructions For Gas Cooking Ranges S U M M A R Y INSTALLATION ........................2 1.1........................2 ENERAL POINTS 1.2..........................2 ANDLING 1.3..........................2 NSTALLATION 1.4..........................3 ATA PLATE 1.5......................... 3 IXING THE FLUE CONNECTING THE APPLIANCE TO THE GAS MAIN ..............
  • Page 3: Installation

    Installation and Set Up Instructions For Gas Cooking Ranges 1. INSTALLATION 1.1. General points Installation must be undertaken in compliance with the following instructions and with local codes and bylaws. Ensure you have a suitable and sufficient risk assessment in place. The user manual must be given to the user after installation.
  • Page 4: Data Plate

    Installation and Set Up Instructions For Gas Cooking Ranges 1.4. Data plate Each apparatus has its own data plate. Transfer all the information on the data plate to the part of the user instructions booklet reserved for it (see the last page). The data plate will ease the communication between you and your client for better service.
  • Page 5: Connecting The Appliance To The Gas Main

    Installation and Set Up Instructions For Gas Cooking Ranges 2. CONNECTING THE APPLIANCE TO THE GAS MAIN Material, assembly and welding tools must be in compliance with the standard EN 45 204. • Fixed appliance: Connect the burner strip to the gas mains using 1/2" NPT pipe and connections. NOTICE Install a shutoff valve in the supply line allowing the unit to be isolated from the rest of the system.
  • Page 6: Connecting The Appliance

    Installation and Set Up Instructions For Gas Cooking Ranges 2.2. Connecting the appliance Fig.1 Gas connection Pressure outlet To reach the pressure outlet: - Remove the control knobs - Remove the control panel (screwed on the lower part) • Units with a gas oven base: To reach the gas connection: - Remove the side panel (fixed with 4 screws).
  • Page 7: Checks After Connection

    Installation and Set Up Instructions For Gas Cooking Ranges 2.3. Checks after connection Ensure of: • The watertightness of the gas pipe and connection. • The supply pressure of the appliance. To take the pressure, do as follow: Remove the control knobs, Remove the control panel, Connect the pressure gauge located on the ramp (see fig.
  • Page 8: Replacing Oven Burner Nozzles And Adjusting The Oven Pilot Light

    Installation and Set Up Instructions For Gas Cooking Ranges Fig.2 • Appliances with gas oven (V01579 – V01455) - Remove the mild steel base to reach the air ring and injector, Air ring - Release the air ring and move it back to reach the injector, - Change the injector (use a 17 mm ring spanner).
  • Page 9: Gas Adjustment Charts

    Installation and Set Up Instructions For Gas Cooking Ranges 3.3. Gas adjustment charts Ø110mm CHART B Open burner Gas type & Mark Calorific Adjustment operating pressure engraved adjustment output in on the d (mm)² injector G20 : Pn = 20 mbar G 25 : Pn = 20 mbar G 25 : Pn = 25 mbar G 30 : Pn = 29 mbar...
  • Page 10: Slow Down Adjustment Procedure

    Installation and Set Up Instructions For Gas Cooking Ranges 3.4. Slow down adjustment procedure Slow down adjustment procedure of the burner: Only a qualified technician is authorized to carry out this adjustment. Thermostatic valve This operation must be carried out very quickly and before the thermostat responds and the burner turns to the maximum output position.
  • Page 11 Installation and Set Up Instructions For Gas Cooking Ranges • Slow down adjustment procedure of the open burner Slow down position of the control knob Slow down screw - Remove the control knobs. - Remove the control panel. - Set the control knob back - Turn on the apparatus (see User Operation and Maintenance Instructions).
  • Page 12: Power Connections

    Installation and Set Up Instructions For Gas Cooking Ranges 4. POWER CONNECTIONS Electric ignition and water filling of removable water tank for burner are considered as options. The apparatus must be earth wired. It is dangerous to connect the apparatus unless it is earthed. Use a standardized cable (245 IEC 57 or 245 IEC 66) or other approved cable with the same characteristics.
  • Page 13: Appliance With Electric Ignition

    Installation and Set Up Instructions For Gas Cooking Ranges 4.2.1. Appliance with electric ignition Inside open base Behind side panel...
  • Page 14: Appliance With Water Filling Of Removable Water Tank For Burner

    Installation and Set Up Instructions For Gas Cooking Ranges 4.2.2. Appliance with water filling of removable water tank for burner Appliance with oven With water tanks + Electric ignition With water tanks Water IN Screw terminal blocks Electric cable Appliance with open base...
  • Page 15: Checks After Connection

    Installation and Set Up Instructions For Gas Cooking Ranges 4.3. Checks after connection After connection, ensure that: The appliance is earth wired, The electrical equipment is properly insulated, The appliance is in good working conditions: thermostat, electric ignition… (see User Operation and Maintenance Instructions).
  • Page 16 Installation and Set Up Instructions For Gas Cooking Ranges...
  • Page 17 Installation and Set Up Instructions For Gas Cooking Ranges WATER TANK + ELECTRIC IGNITION WATER OUT...
  • Page 18 Installation and Set Up Instructions For Gas Cooking Ranges THERMOSTATIC VALVE ST35 SE0117/0 1~230V NOMENCLATURE: THERMOSTATIC VALVE (SE0117/00) Ref. Description Mark Quantity 502002 Thermostat 08425A Solenoid valve Terminal...
  • Page 19 Installation and Set Up Instructions For Gas Cooking Ranges...
  • Page 20: Water Connection

    Installation and Set Up Instructions For Gas Cooking Ranges 6. WATER CONNECTION Connect on a male nozzle 6/8 located on the solenoid valve (see page10). After connection, check the watertightness and the good functioning of the water circuit. Fig. E Water IN Hose coupler Male nozzle 6/8...
  • Page 21: Basic Spare Parts List

    Installation and Set Up Instructions For Gas Cooking Ranges 7. BASIC SPARE PARTS LIST Description Code # Photo Description Code # Photo Oven injectors G30,G31 Thermocouple propane gas  1.70 00201A Open burner 00291A G20,G25 Natural gas  2.50 Oven 00290A 00209A Little fire Open burner...
  • Page 22 Installation and Set Up Instructions For Gas Cooking Ranges Désignation Code Photo Désignation Code Photo Solenoid valve Cable of 174004 507650 connecting water tank Tripolar Heating element 02063A thermostat 01990A 2500 W 400 V 300°C Indicator red 173644 400 V Switch for oven 00831A Indicator white...
  • Page 23 V01927 V01952 R-G2FN V01626 V01735 OPEN BURNERS ON OPEN CUPBOARD (not contractual photographs) CHARVET User Instructions : 800/900 UK GFN F-38850 CHARAVINES French edition: 31.08.2006; Update number E Tel.: (33) 4-76-06-64-22 English edition: 17.01.2008; Update number B Fax: (33) 4-76-55-78-75...
  • Page 24 User Operation and Maintenance Instructions For Gas Cooking Ranges S U M M A R Y INTRODUCTION ........................2 PRIOR TO STARTING UP ...................... 2 STARTING UP ........................3 3.1.......................... 3 PEN BURNERS 3.2..........................3 AS OVEN 3.3..........................
  • Page 25: Introduction

    User Operation and Maintenance Instructions For Gas Cooking Ranges 1. INTRODUCTION 1. Our equipment is for professional use only and must be used by qualified staff. 2. The equipment must be installed in compliance with local codes and bylaws. It must be installed in a kitchen equipped with an adequately sized mechanical extraction system.
  • Page 26: Starting Up

    User Operation and Maintenance Instructions For Gas Cooking Ranges 3. STARTING UP Each burner is equipped with a flame failure safety cut out thermocouple and a pilot light. 3.1. Open burners - Push and turn control knob counter-clockwise of desired burner to the spark symbol (pilot light).
  • Page 27: Water Tank

    User Operation and Maintenance Instructions For Gas Cooking Ranges 3.3. Water tank Water IN Sluice gate Fig. I : water tank • Checks before use PUSH BUTTON - The sluice gate must be positioned in the middle of the CONTROL KNOB Only water tank water tank (Fig.
  • Page 28: Switching Off

    User Operation and Maintenance Instructions For Gas Cooking Ranges 4. SWITCHING OFF Bring the control knobs back to the “ “ position as well as the oven thermostat. At the end of the day, cut off gas supply or switch off electricity at the mains. 5.
  • Page 29 User Operation and Maintenance Instructions For Gas Cooking Ranges * heavy parts This apparatus must not be cleaned with water under pressure or too much water splashed onto the burners as this might obstruct the gas supply. Ensure that it is switched off at the mains.
  • Page 30: Possible Causes Of Breakdown

    User Operation and Maintenance Instructions For Gas Cooking Ranges 6. POSSIBLE CAUSES OF BREAKDOWN Breakdown Probable causes Clogging of the burners, injectors… Unsatisfactory heating Incorrect gas pressure Incorrect grading of the injectors Clogging of the rear internal flue box Incorrect temperature of the Faulty thermostat oven Clogging of the pilot light...
  • Page 31: Data Plate

    User Operation and Maintenance Instructions For Gas Cooking Ranges 7. DATA PLATE Transfer below information written on the data plate of your apparatus. This will help you with maintenance problems and spare parts.

Table of Contents