POWER WAVE
S350
POWER FACTOR CORRECTION CONTROL BOARD
REMOVAL AND REPLACEMENT PROCEDURE
Figure F.29 – Power factor correction control board plug locations
REPLACEMENT PROCEDURE
1. Carefully connect plugs J23, J24, J25, J26 and J27 to the new
power factor correction control board. See Wiring Diagram.
2. Carefully position the power factor correction control board on to
the mounting posts.
3. Using a 3/8" nutdriver, attach the three nuts securing the power
factor correction control board to the machine.
4. Perform the Case Cover Replacement Procedure.
5. Perform the Retest After Repair Procedure.
J26
J23
J24
TROUBLESHOOTING AND REPAIR
J27
J25
(continued)